Programming
The following parameters can be set (3rd column: basic setting):
11
P10
relay function
0 0 = H1 and H2 fleeting
0 1 = H1 solid state, H2 fleeting
1 0 = H1 fleeting, H2 solid state
1 1 = H1 and H2 solid state
0 0
P01
counting function
0 = VRD (up / down differential; electronic and mechanical
pulse pick-ups)
1 = VR (up / down; incremental shaft encoders)
1
0
control inputs for electronic or mechanical pulse pick-ups
0 = pnp switching
1 = npn switching
P02
P03
decimal places
0 ... 3 = 0 ...3 decimal places after the point
0
0
last value memory
0 = last value memory active
(on power up the last value is displayed)
1 = last value memory not active
(on power up the preset value is displayed)
P04
P05
front reset
0 = front reset active
1 = front reset not active
0
0
edge evaluation
0 = one-fold evaluation
1 = two-fold evaluation
2 = four-fold evaluation
P06
P07
change of signs
0 = change of signs active
1 = change of signs not active
0
P08
multiplication factor
multiplication of the input pulses by factor
0.0001 ... 9.9999
(if P11 is set to 4 or 5, only factors
≤
1.0000 should be
used)
1,0000