PWM in the ecomatmobile controller
Hydraulic control in PWM
193
Parameters of the function outputs
Name
Data type Description
OUT1
WORD
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve left
OUT2
WORD
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve right
OUT3
INT
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve on output module
(e.g. CR2011 or CR2031)
WRONG_MODE
BOOL
Error: invalid mode
ERR1
BYTE
Error code for rising edge:
0 = no error
1 = error in array: wrong sequence
2 = initial value IN not contained in value range of array
4 = invalid number N for array
ERR2
BYTE
Error code for falling edge:
0 = no error
1 = error in array: wrong sequence
2 = initial value IN not contained in value range of array
4 = invalid number N for array