12
1
2
E2M232
(2) Analogue video input
M16 socket, 4 poles
2
1
3
4
1
2
3
4
Coax cable core
(video signal)
Coax screen
(video GND)
U+ (12 V DC)
GND
6.3 Connection and laying of cables
►
Use screened cables from ifm: www�ifm�com
E2M203: M16 connection cable, gold-plated contacts, 5 m long
E2M204: M16 connection cable, gold-plated contacts, 11 m long
E2M205: M16 connection cable, gold-plated contacts, 16 m long
E2M206: M16 connection cable, gold-plated contacts, 21 m long
►
Use screened connector housings�
►
Do not lay the cables in parallel to live cables�
►
Lay supply and signal cables away from the cameras using the
shortest possible route�
6.4 Operating voltage and fuses
NOTE
Not using a common ground can damage the device and certain
cameras� If an O3M2xx is used as camera:
►
Connect GND connections of O3M2xx and E2M23x�