background image

18

19

Operating the Shower 

cont.

Adjusting the Showerhead

Your showerhead has 3 spray modes - spray, jet spray and 
combination. Simply rotate the spray head one way or the 
other until it ‘clicks’ into the desired spray pattern.

Note: 

The spray head mode may need to be altered 

during winter conditions (low flow conditions) to achieve a 
satisfactory spray.   

Maintenance 

General Cleaning

Before attempting to clean your shower unit you must 
switch off the power at the isolating switch. Do not remove 
the cover.

Do not use abrasive cleaners or solvents to clean this unit. 
The shower unit and accessories should be cleaned with a 
soft, clean, damp cloth.

Cleaning the Showerhead

Your showerhead has a rub-clean pad for easy cleaning. 
Simply rub your fingers across the rubber spray jets 
regularly and before you  turn the shower on to remove any 
scale or debris. 

The hardness of the water in your area will determine how 
often you should clean your showerhead. Build up of scale 
in particularly hard water areas combined with constant 
use means you may need to clean your showerhead once 
a week. To ensure continued performance of your electric 
shower the showerhead needs to be regularly descaled.

continued on next page

Spray

Jet spray

Combination 
spray

Need help?

 For further technical help or advice please contact your point of purchase.

Содержание Thirle Electric Shower 8.5 Kw

Страница 1: ...klet for future reference Installer when you have read these instructions please ensure you leave them with the user Electric Showers Installation Instructions User Guide eco 2 Year Guarantee Thermost...

Страница 2: ...asy to install and enjoyable to use It has also been designed and tested in the UK to all of the relevant British Standards These instructions contain all of the necessary installation and operating i...

Страница 3: ...foreign object Do not operate the shower if the water stops flowing during use or if the water is leaking from the shower unit itself Turn off at the mains electrical supply and refer to the Troublesh...

Страница 4: ...se will be happy to assist Tools Required Not supplied Phillips screwdriver Drill 6mm Drill bit Electrical tester Spirit level Pencil Electrical pliers Junior hacksaw Utility knife File Pack Contents...

Страница 5: ...power to the heating elements Once the unit cools down to a safe temperature the elements will come on again and reheat the water within the water heater and the whole cycle will repeat itself until t...

Страница 6: ...onsumer unit specifically for the shower A separate and permanently connected cable must be taken from the consumer unit directly to the shower via a 45 Amp double pole switch with a minimum contact s...

Страница 7: ...he UK Network In domestic installations you must ensure that the electrical supply and existing fuse board are adequately rated Do not turn on the electrical supply until the plumbing has been complet...

Страница 8: ...he diameter of the inlet pipe to the fitting whichever is the greater Water Requirements Double pole switch Shower unit Shower tray spillover level Bath spillover level Hose retainer Minimum 20mm betw...

Страница 9: ...through the paper Remove the template from the wall and drill the wall to suit the wall fixings to be used L N Fixing Your Shower to the Wall Tips A piece of insulation or masking tape positioned whe...

Страница 10: ...N L N Bottom left inlet entry Bottom right inlet entry Top left inlet entry Rear left inlet entry using a 15mm compression elbow not supplied Rear left inlet entry requiring rear access Rear right inl...

Страница 11: ...Inlet Entry Options The pipe work can enter the shower unit from 6 different positions Bottom left Bottom right Top left Rear left Rear right or Rear left using an elbow as shown on page 10 To top or...

Страница 12: ...Turn on the water supply and inspect for water leaks at the shower inlet Once inspected turn off the water supply Pressure Relief Device PRD A pressure relief device is designed into this shower The p...

Страница 13: ...ntirely Pipe cover Blanking cover L N L N L N Warning This appliance and all connecting metal pipe work must be earthed Ensure that an earth continuity conductor is securely and permanently connected...

Страница 14: ...ly to allow cables to be directed to the terminal connection block within the unit Note When feeding cable through bottom entry points remove highlighted grey tab on pipe blanking cover if using 6mm c...

Страница 15: ...ly cable must be secured by routing through conduit or in trunking or by being embedded in the wall in accordance with current I E E Regulations Warning Do not switch on power to the shower unit until...

Страница 16: ...p tools equipment into basin bath or shower during shower installation Drill the wall at the marked fixing position to suit the wall fixings to be used loosely fix the rail with the large hole on the...

Страница 17: ...r the water to flow correctly Once the water has flowed for a further 10 seconds rotate the temperature control knob 3 from the fully clockwise position to the fully anti clockwise position Repeat thi...

Страница 18: ...START button 1 Phased Shut Down When the shower is turned off water will continue to flow for a short period of time while the heater cools down This ensures that the shower is ready for the next use...

Страница 19: ...shower unit and accessories should be cleaned with a soft clean damp cloth Cleaning the Showerhead Your showerhead has a rub clean pad for easy cleaning Simply rub your fingers across the rubber spra...

Страница 20: ...set Contact your point of purchase Letters LP appear on the front panel just above the START STOP button Low Pressure water supply to shower unit Low water flow through shower handset Turn off unit an...

Страница 21: ...1 Metal Clip x1 inc O ring x1 1 08 131 309 S Pressure Relief Diaphragm Housing Ass Pressure Relief Diaphragm Housing x1 inc Screws x2 1 09 131 308 Pressure Relief Diaphragm Pressure Relief Diaphragm x...

Страница 22: ...22 Spare Parts Need help For further technical help or advice please contact your point of purchase 7 15 20 4 8 9 19 10 1 5 6 11 12 13 14 17 18...

Страница 23: ...t End Caps x2 Screws x2 Wall Plugs x2 1 03 207041 Riser Rail Ass Riser Rail x1 Riser Rail End Caps x2 1 04 1625A0A Slider Handset Holder Slider Handset Holder x1 1 05 D1001 Soap Dish Soap Dish x1 1 06...

Страница 24: ...Issue FI ES TP A Part Number 297 902...

Отзывы: