1. Introduction 

1.1 Product range 

This handbook describes the operation and 
programming for the IES EC24 & EC12 rack 
mounting dimmer pack. The dimmers covered by 
this handbook are: 

9602  

EC12I, 12 x 1kW, 20A three 
phase input,  2 x harting output 

9804  

EC24I, 12 x 2,5kW, 40A three 
phase input, 2 x harting output 

1.2 Main features of the EC dimmer 

The EC dimmer is a fully digital triac dimmer pack 
with fuse over current protection per circuit. LED 
Status information per channel. This dimmer is a 
Low cost solution for a wide range of destinations.  
 

2. Unpacking and installation 

2.1 Unpacking & checking 

The EC dimmer pack is a self-contained dimming 
system and only requires a suitable mains input 
connector.  
 
The EC dimmer pack is packed to withstand normal 
transportation, but before operating the unit, check 
there is no sign of transit damage which could affect 
the operation and safety of the dimmer. 

2.2 Positioning 

The EC dimmer pack is an extremely versatile 
dimmer, and can be incorporated in a 19” equipment 
rack, or used as a portable dimmer. It is designed for 
forced ventilation cooling and care must be taken to 
ensure adequate ventilation especially when the EC 
is built into a cabinet. The EC is supplied with 
mountings suitable for 19” equipment enclosures, 
and accommodates 2U of panel space. 

2.3 Connections 

Note: All electrical connections to the EC dimmer 

pack must be made by a suitably qualified 
person. 

2.3.1   Power input connections  

Input power is supplied via a 3-phase, neutral and 
earth 4mm

2

 flexible cable. A suitable plug and 

socket, such as a 32A three phase CEE17, is 
recommended. 
 
 

2.3.2  Power output connections  

The EC has a cable 5 x 4mm2. Connections to the 
loads are simply made by fitting the appropriate plug 
to the load cable. 

2.3.3 DMX data signal connections  

The dimmers are controlled using DMX 512. This is 
connected by a two-pair and shield high-speed data 
cable with XLR 5-pin connectors (male = input; 
female = output).  

Pin connections are:  

1   0V shield 

2 DMX 

3 DMX 

4 - 

DATA 

5 + 

DATA 

The DMX network supports up to 32 PR-6 dimmer 
packs (192 dimmers in total) connected to each 
DMX line. For larger installations where more DMX 
lines are required, the use of a DMX booster/isolator 
is recommended. Any booster/isolator used has to 
accommodate bi-directional data on pins 4 and 5 for 
DimSTAT to operate. Suitable boosters are IES 
code 9601 (5 channels) or 9815 (10 channels). 
 
Termination is required for DMX data on all 
networks. The last DMX output socket in the line has 
to be terminated with two 120

 1/4 Watt resistors 

connected between pins 2 and 3 (DMX). A ‘dummy 
plug’ XLR male connector with the termination 
resistors fitted is recommended for this purpose. 
 

2.4 Safety 

Even though the EC dimmer pack is equipped with 
Fuses per channel, all normal electrical safety 
procedures must be applied. Do not use the dimmer 
if the mains input cable has been damaged, or the 
body of the case is not intact. Do not expose the unit 
to rain or moisture. To avoid electrical shock, do not 
open the cabinet. Refer servicing to qualified 
personnel only. 
 

2.5 Warranty 

We warrant each of our products to be free from 
defects in material and workmanship. Our obligation 
under this warranty is to repair or replace any 
instrument of part thereof which, within two Years 
after shipment, proves defective upon examination. 
External influences are excluded. To exercise this 
warranty, write or call Your local IES representative, 
or contact IES service department. You will be given 
prompt assistance and shipping instructions. 
 
 

 

IES EC24 & EC12 dimmer pack Operators’ Manual v. 1.0          

20-10-2003

 2 

Содержание EC 12

Страница 1: ...4 Safety 2 3 Control panel layout 3 4 Function DEL H MENU 4 4 1 Adjusting minimum output 4 4 2 Adjusting maximum output 4 4 3 Select Solid state function 4 4 4 Adjusting delay times 4 5 Function DEL T MENU 5 5 1 Select Dimmer curve 5 5 2 DMX 512 Back up facility 5 6 Function DEL U MENU 5 6 1 Serial communication 5 7 Return to factory settings 6 8 Dimmer overview 7 9 Specifications 8 10 Declaration...

Страница 2: ... simply made by fitting the appropriate plug to the load cable 2 3 3 DMX data signal connections The dimmers are controlled using DMX 512 This is connected by a two pair and shield high speed data cable with XLR 5 pin connectors male input female output Pin connections are 1 0V shield 2 DMX 3 DMX 4 DATA 5 DATA The DMX network supports up to 32 PR 6 dimmer packs 192 dimmers in total connected to ea...

Страница 3: ...ress the DEL button within 5 seconds the min and max buttons The displayed values should be written including frequency and software number if You might encounter any problem Your dealers need information to assist in an adequate way H Selects the hundreds T Selects the tenths U Selects the units CHANNEL BUTTON AND INDICATION Use these key s to adjust the output level between 0 25 50 75 100 Led s ...

Страница 4: ... or max key 4 3 SELECT SOLIDSTATE FUNCTION Each dimmer channel can function as a dimmer or as a switch solid state channel zero crossing To select the switch function enter the maximum channel output adjustment using the key sequence del H and max The switch function is active if the maximum output is set to 100 Adjust the display until it indicates until it indicates 99 9 Now press the U key The ...

Страница 5: ...scene is now recorded Channel three Disable off Enable on Exhibition mode This means that a setting can be made with the channel buttons and automatically recorded after 60 seconds This menu can be left by pressing the H button 6 DEL U MENU SETTINGS To enter DEL U menu press DEL and U for 5seconds 6 1 SERIAL COMMUNICATION The Del U menu controls parameters for SERIAL communication with a PC This m...

Страница 6: ... RETURN TO FACTORY SETTINGS To return to the factory settings Make the dipswitch setting at the inside off the EC dimmer as below When dipswitch is placed remove power from EC dimmer Plug in Power again Display shows 555 Dipswitch settings normal use Dipswitch setting to reset the EC dimmer IES EC24 EC12 dimmer pack Operators Manual v 1 0 20 10 2003 6 ...

Страница 7: ...immer channel 1 4 B Dimmer channel 5 8 C Dimmer channel 9 12 D ceramic fuse 6 3 A E Blower F Glass fuse 400mA G Output 7 12 H Output 1 6 I Power input 3 x 230VAC IES EC24 EC12 dimmer pack Operators Manual v 1 0 20 10 2003 7 ...

Страница 8: ... Size 483mm x 93mm x 280mm Weight 6 0kg connectors Supply connection 5 x 4mm 2 cable output sockets 12 6 x 2 Output type HAN E 16F Harting product ref EC12 EC24 Control connectors in and out XLR 5 DMX data pins 2 3 Data pins 4 5 control data Control signal DMX 512 4 wire DMX and DATA bi directional data Max level preset 30 0 100 full Min level preset 0 0 29 9 Response time 0 00 secs 9 9 secs up an...

Страница 9: ...12 24 no 9602 9804 Conforms to the following product Specifications Emission EN 50081 1 EN 50081 2 EN 55011 EN 55014 Immunity EN 50082 1 EN 50082 2 EN 55024 2 6 kV Contact discharge 8 kV Air discharge EN 55024 3 3 V m EN 55024 4 1 kV Signal lines 2 kV Power lines Supplementary information The product complies with the EMC Directive 89 336 EEC Veenendaal December 2000 J H D de Jonge Technical Manag...

Отзывы: