background image

Single Pole (One location) or 3-Way (Multi-location)

Rotary Dimmer

120VAC, 60Hz

Cat. No. RPIØ6-1L, 600W (Lighted)

Cat. No. RPIØ6-1Ø, 600W

INSTALLATION INSTRUCTIONS

PK-93316-10-00-2B

Tools needed to install your Dimmer:

Slotted/Philips Screwdriver

Electrical Tape

Pliers

Pencil

Cutters

Ruler

Installing Dimmer by itself or with other devices:

If installing Dimmer in a single device application, proceed with the

INSTALLING YOUR DIMMER

 section. If installing Dimmer in a multi-

device application, proceed as follows:

MULTI-DEVICE APPLICATION:

In multi-dimmer installations, the reduction of the dimmer’s capacity is
required. Refer to the chart for maximum load per dimmer.

INSTALLING YOUR DIMMER

NOTE: 

Use check boxes       when Steps are completed.

WARNING:

 To avoid fire, shock, or death; 

TURN OFF

POWER

 at circuit breaker or fuse and test that power is off

before wiring!

Removing existing switch:

 

Remove existing wallplate

and switch mounting screws. Carefully pull switch from wall
box. 

DO NOT

 remove wires attached to the switch at this

time.

Identifying your wiring application (most
common):

NOTE:

 If the wiring in the wall box does not resemble any of

these configurations, consult a qualified electrician.

Disconnecting switch wires and preparing wires:

Step 2

Single-Pole Wiring Application:

Step 4

Connect wires per WIRING DIAGRAM as follows:

Screw wire nuts on clockwise making sure no bare conductors
show below the wire connectors. Secure each connector with
electrical tape.

Green dimmer Ground lead to Green or bare copper wire in
wall box.

Black dimmer lead to any wall box wire removed from old
switch.

Red dimmer lead without insulating label to remaining
wall box wire.

Remaining Red dimmer lead should have Red insulation
label affixed.

NOTE: 

If insulating label is not affixed to Red lead, use

a small wire nut or electrical tape to cap off.

• Proceed to Step 6.

Step 1

Step 3

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Single-Pole:

Look at the back of your switch.
If there are 2 wires connected to
two screw terminals (not
including a green or bare copper
wire used for grounding), you
have a Single-Pole switch.

3-Way:

Look at the back of your switch. If
there are 3 wires connected to  three
screw terminals (not including a
green or bare copper wire used for
grounding), you have a 3-Way switch.
Note that one of the screw terminals
will usually be a different color (black)
or labeled Common. Tag that wire
with electrical tape to identify.

Tag Common

Screw Wire

WARNINGS:

• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to

control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.

• Use only one (1) dimmer per load. The switch(es) will turn the light on at the brightness level

selected at the dimmer.

CAUTIONS:

• Use with incandescent or 120V halogen fixtures only.
• Disconnect power at circuit breaker or fuse when servicing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked

CO/ALR or CU/AL.

• Disconnect wires from screw terminals or

Quickwire™ slots (shown).

• Pull off pre-cut insulation from Dimmer

leads.

• Make sure that the ends of the wires from

the wall box are 

straight (cut if

necessary)

.

• Remove 5/8" (1.6 cm) of insulation from

each wire in the wall box (shown).

For Single-Pole Application, go to Step
5A.

For 3-Way Application, go to Step 5B.

Strip 5/8"

Cut

(if necessary)

Press in slot and

pull out wire

Strip Gage

5/8"

Black

Red

Neutral

Green

Ground

Red

This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.

Step 5a

Insert wires

straight then

twist

clockwise

Electrical

Tape

More than

 Cat. No.

 Single

Two Devices 2 Devices

 RPIØ6-1L

  600W

    500W

400W

 RPIØ6-1Ø

  600W

    500W

400W

MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE

Отзывы: