3-Way Wiring Application:
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.
NOTE:
Control can be installed on either the Load or Line side.
•
Green dimmer Ground lead to Green or bare copper
wire in wall box.
•
Black dimmer lead to tagged (common) wall box wire
identified when removing old switch.
•
Remove Red insulating label from Red lead.
•
Any Red dimmer lead to any of the remaining wall box
wires.
•
Remaining Red dimmer lead to remaining wall box wire.
Testing your Dimmer prior to mounting in wall
box:
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s
only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to
Leviton Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.
This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper
environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and
fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this
warranty, whether based on contract, tort or otherwise.
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Restore Power:
Restore power at circuit breaker or
fuse.
Installation is complete.
OPERATION
NOTE:
The indicator light will illuminate when the load is OFF
to facilitate access in the dark.
NOTE:
If using the dimmer in a 3-way application, the lights will
turn ON at brightness set on dimmer's control knob. The lighting
can be controlled from either the dimmer or the switch location.
Black
Red
Neutral
Green
Ground
Red
Step 6
Step 7
Installation may now be
completed by carefully
positioning all wires to
provide room in wall box for
dimmer. Mount dimmer
into box with mounting
screws supplied. Attach
Decora
®
wallplate.
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 or 2 #16 or #18
1- #14 w/ 1 to 4 #16 or #18
2- #14 w/ 1 to 3 #16 or #18
For non-standard wiring applications, refer to
Wire Nut and Connector Size Chart
Step 5b
Insert wires
straight then
twist
clockwise
PK-93316-10-00-2B
Step 8
Electrical
Tape
• Restore power at circuit breaker
or fuse.
• Carefully holding Dimmer as
shown,rotate knob fully
clockwise to highest position.
Lights should turn ON to
brightest level. If lights do not turn
ON, depress push-button switch
(dimmer knob) once. Lights
should turn ON to brightest level.
If lights still do not turn ON,
refer to the
TROUBLESHOOTING section.
ON:
Depress push-button switch (dimmer
knob) to ON position – Lights will turn
ON.
OFF:
Depress push-button switch (dimmer
knob) to OFF position – Lights will
turn OFF.
BRIGHTEN:
Rotate control knob clockwise – Lights
will BRIGHTEN to desired level.
DIM:
Rotate control knob counter-clockwise
– Lights will DIM to desired level.
TROUBLESHOOTING
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with wire connectors.
• Light does not turn ON and ON/OFF LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
NOTE: If further information is needed in identifying the HOT wire in
a 3-Way application, go to
Leviton's website at www.leviton.com.
PRODUCT INFORMATION
• For technical assistance, contact us at
1-800-824-3005
.
• Visit our website at
www.leviton.com
.