OPERATING INSTRUCTIONS

 

Spidy Cable Reel  

 

16 

 

 

 

Protective earth (c) = yellow and green 

cable with earth wire 

 

N (neutral conductor) = blue cable (not 
fused) 

 

L1 (wire 1, phase) = brown cable 

(fused) 

 

 

Note!

 

When connecting, make sure to 

connect the yellow and green 

cable with the earth wire to the 

lustre terminal marked with the 

earth symbol 

c

 and that strain 

relief is screwed tight. 

4.

 

Tighten the screws of the lustre termi-

nal and strain relief. 

5.

 

Screw the cover closed. 

 

4.3.4

 

Connecting a Spidy ROLLER 
230 V (with Compressed Air 
Supply) to the Mains Supply 

1.

 

Screw off the cover as described in 

Chapter  4.3.1

 

C

ONNECTING A 

S

PIDY 

ROLLER

 

12

 

V

 

/

 

24

 

V

 

(

WITHOUT COM-

PRESSED AIR SUPPLY

)

  TO THE BATTERY TEST-

ING AND CHARGING SYSTEM

. 

2.

 

Loosen the screws of the lustre termi-

nal. 

3.

 

Connect the cable reel to the mains 

supply as shown in the graphic below: 

 

 

Protective earth (c) = yellow and green 

cable with earth wire 

 

N (neutral conductor) = blue cable (not 

fused) 

 

L1 (wire 1, phase) = brown cable 

(fused) 

 

L2 (wire 2) = black cable 

 

Содержание Spidy ROLLER 230 V

Страница 1: ...30226 Spidy AIRROLLER 230 V with Multifunctional Plug 30876 Spidy ROLLER 12 24 V 30569 Spidy ROLLER 12 24 V with 7 Pole Plug 30679 Spidy AIRROLLER 12 24 V 30223 Spidy AIRROLLER 12 24 V with Combined A...

Страница 2: ...roduction method whatsoever is prohibited without the prior permission of Industrieelektronik P lz GmbH These operating instructions do not represent a contractual relationship We reserve the right to...

Страница 3: ...er 10 3 4 2 Cable Locking 10 3 4 3 Fuse 10 4 Installation 12 4 1 Unpacking the Cable Reel 12 4 2 Mounting the Cable Reel 13 4 3 Connecting the Cable Reel 14 4 3 1 Connecting a Spidy ROLLER 12 V 24 V w...

Страница 4: ...ng Springs 22 8 Appendix 23 8 1 Technical Data 23 8 1 1 Spidy ROLLER 12 V 24 V without Compressed Air Supply 23 8 1 2 Spidy ROLLER 12 V 24 V with Compressed Air Supply 23 8 1 3 Spidy ROLLER 230 V with...

Страница 5: ...of convenience due to the cable locking and individual stop de vice settings The cable reel is compatible with Industrieelektronik P lz GmbH s com bined plugs and sockets 1 1 Liability and Warranty U...

Страница 6: ...nstructions to ensure perfect operation of your cable reel 1 4 Explanation of Symbols and Instructions This symbol warns you of a hazardous location This signal word describes the severity of the immi...

Страница 7: ...d manually Any other use is not the intended use and voids the warranty 2 2 General Safety Information This cable reel is not intended for use by anybody including children with physical sensory or me...

Страница 8: ...e 12 V 24 V cable reel with or without a compressed air supply is for supplying the battery testing and charging system or a similar device that is installed in the vehicle hall The 230 V cable reel w...

Страница 9: ...pidy AIRROLLER 230 V Item number 30226 Spidy AIRROLLER 230 V with mul tifunctional plug for socket Item number 30876 Please note the device specific description and equipment of your cable reel Note T...

Страница 10: ...out the cable the spring latch runs over latch cams Lock the cable by using four screws to clamp the lamella clamp tight at the de sired gripping height of 1 m to 6 30 m with the Spidy ROLLER 230 V u...

Страница 11: ...epending on the device type one or two fuses are used Note Fuse protect all the positive pole connections e g between the battery testing and charg ing system and the battery or between the main and a...

Страница 12: ...1 5 mm Printing on the wires 1 2 3 4 Air hose 4 mm approx 1 m 1 8 threaded joint 30677 with combined air plug 30875 with combined air plug for socket Spidy ROLLER 230 V Item number 30222 Commercially...

Страница 13: ...sal bracket to the wall or ceiling 2 Push the cable reel onto the universal bracket s bolt 3 Push the slide into the recess on the universal bracket to secure the cable reel 4 Fix the slide using the...

Страница 14: ...ed socket on the vehicle or make another connec tion to the battery system Danger electrical hazard Check that the cable reel and all its cables are in perfect condition before use Caution Do not use...

Страница 15: ...PPLY TO THE BATTERY TESTING AND CHARGING SYSTEM 2 Connect the air hose to the com pressed air supply system in the vehicle hall to ensure the supply of com pressed air To do this proceed as fol lows 3...

Страница 16: ...the lustre termi nal and strain relief 5 Screw the cover closed 4 3 4 Connecting a Spidy ROLLER 230 V with Compressed Air Supply to the Mains Supply 1 Screw off the cover as described in Chapter 4 3 1...

Страница 17: ...the lustre termi nal and strain relief 5 Connect the air hose to the com pressed air supply system in the vehicle hall to ensure the supply of com pressed air see also ter 4 3 2 CONNECTING A SPIDY ROL...

Страница 18: ...case of severe inductive loading If under heavy load pull the cable out completely Caution The supplied cables are rated for normal operation Do not overtension the cable e g by hanging weights from i...

Страница 19: ...charging system 6 1 1 Dismounting the Cable Reel Note Ensure that all the cable has been reeled in 1 Loosen the slide s locking screw to pull the slide 2 Pull the cable reel off the universal bracket...

Страница 20: ...off the wall or ceiling before starting any servicing work 7 1 Maintenance Note The cable reel is maintenance free 7 1 1 Checking and Replacing Fuses 1 Screw off the cover as described in Chapter 4 3...

Страница 21: ...ff the axis 7 Loosen the screws and carefully take the bottom slip ring half out of the spool 8 Loosen the cable from the lustre ter minal of the bottom slip ring half Note Take note of the correct se...

Страница 22: ...d push it far enough forwards for it to touch the contacts of the bottom slip ring half 18 Guide the wires through the opening in the housing cover 19 Press the housing cover onto the axis supports an...

Страница 23: ...m max Supported media Power supply Fuse Not fused Item number 30569 30679 with 7 pin plug 8 1 2 Spidy ROLLER 12 V 24 V with Compressed Air Supply Rated voltage 12 V 24 V Transition resistance 0 8 mOhm...

Страница 24: ...m max Supported media Power supply Fuse Fuse 10 A slow blow Item number 30222 8 1 4 Spidy AIRROLLER 230 V with Compressed Air Supply Rated voltage 230 V Transition resistance 0 8 mOhm Temperature ran...

Страница 25: ...ufactured and inspected in accordance with valid stand ards and guidelines and recognized tech nical regulations To obtain the complete inspection certifi cation please contact our customer ser vice o...

Страница 26: ...8 OPERATING INSTRUCTIONS Spidy Cable Reel 26...

Страница 27: ...8 OPERATING INSTRUCTIONS Spidy Cable Reel 27...

Страница 28: ...ustrieelektronik P lz GmbH IEP P lz GmbH Gro endorf 122 Laufener Stra e 15a 4551 Ried im Traunkreis Austria 83395 Freilassing Germany Tel 43 0 7588 70 122 Tel 49 0 8654 478 670 Fax 43 0 7588 70 125 Fa...

Отзывы: