GB
9 - PART REPLACEMENT
MASTER 880MP E-volution
9 - Pag. 2 / 4
9.1
FEED CHAIN - REPLACEMENT
Replacement of the feed chain is a highly complex operation; call IEMCA after-sales service.
9.2
PLC BATTERY - REPLACEMENT
Replace the battery at least every year, and when the following message is displayed: "PLC
battery exhausted"
INFORMATION:
when this message is displayed, the battery
should be replaced within one day, otherwise,
the "PLC/NC Software" data will be deleted.
• Unscrew cap (A) and pull out battery (B);
• insert a new battery (AA 3.6volts lithium-type battery)
and make sure that it is introduced correctly, then
tighten the cap (A).