EN
4 - HANDLING AND INSTALLATION
BOSS 552-IC
4 - Pag. 26 / 28
4.8.2.1 EMERGENCY STOP
4 emergency channels are available, 2 from bar feeder to lathe and 2 from lathe to bar feeder.
· Emergency from the bar feeder to the lathe (2 channels, open
contacts=Emergency activated).
It allows transmitting the active emergency state from the bar feeder to the lathe.
These signals should be integrated with the lathe emergency signals, so that in case of an
emergency stop, the whole unit (lathe/bar feeder) is stopped.
· Emergency signal from lathe to bar feeder (2 channels, contacts off = Emergency
activated).
It allows transmitting the active emergency state from the lathe to the bar feeder.
As soon as the bar feeder receives these signals, an emergency stop (safety class 3) is
activated.
4.8.2.2 GUARD SAFETY STOP (IF PROVIDED)
4 guard safety channels are available, 2 from bar feeder to lathe and 2 from lathe to bar
feeder.
· Guard safety signal from the bar feeder to the lathe (2 channels, open
contacts=open guards).
Whenever the above mentioned channels are closed, the bar feeder informs the lathe that the
guards are closed: all lathe operations, displacement included, are now allowed.
Whenever one of the bar feeder guards is open, these signals are stopped: in this case, the
lathe immediately stops (safety class 3) all the movements that may harm the operator (i.e. in
the multispindle, the spindle drum displacement).
As soon as the contacts are closed, the lathe will start operation again.
· Guard safety signal from lathe to bar feeder (2 channels, contacts off = open
guards).
Whenever the above mentioned signals are closed, the lathe informs the bar feeder that the
guards are closed: the bar feeder can move the bar pusher forwards.
As soon as one of the guards on the lathe is open, the bar feeder is stopped immediately, in
agreement with safety class 3, to avoid injury to the operator.
Some jumpers may be fitted on the safety signals for bar feeder testing purpose only.
Therefore, they should be removed in order to restore the safeties.
DANGER-WARNING!!!
The bar feeder safety depends on these connections, therefore IEMCA is not responsible for any
possible damage to persons or things, caused by improper use of the above mentioned signals.
Содержание BOSS 552 - IC
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 15: ...1 GENERAL INFORMATION BOSS 552 IC EN 1 Pag 5 5 ...
Страница 43: ...EN 2 TECHNICAL INFORMATION BOSS 552 IC 2 Pag 28 28 ...
Страница 49: ...EN 3 SAFETY GENERAL INFORMATION BOSS 552 IC 3 Pag 6 6 ...
Страница 101: ...EN 5 ADJUSTMENTS AND SETUP BOSS 552 IC 5 Pag 24 24 ...
Страница 118: ...6 USE AND OPERATION BOSS 552 IC EN 6 Pag 17 20 Stop the lathe Turn the main power switch to O OFF ...
Страница 129: ...EN 7 BAR FEEDER MAINTENANCE BOSS 552 IC 7 Pag 8 8 ...
Страница 133: ...EN 8 TROUBLES CAUSES SOLUTIONS BOSS 552 IC 8 Pag 4 4 ...
Страница 139: ...EN 9 PARTS REPLACEMENT BOSS 552 IC 9 Pag 6 6 ...
Страница 155: ...EN 11 COLLETS BOSS 552 IC 11 Pag 2 34 ...
Страница 164: ...11 COLLETS BOSS 552 IC EN 11 Pag 11 34 ...