KINO-QM57A Mini-ITX SBC
Page 142
NOTE:
When exiting a program it is necessary to disable the Watchdog Timer,
otherwise the system resets.
Example program:
;
INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
MOV AX, 6F02H
;setting the time-out value
MOV BL, 30H
;time-out value is 48 seconds
INT 15H
;
;
ADD THE APPLICATION PROGRAM HERE
;
CMP EXIT_AP, 1
;is the application over?
JNE W_LOOP
;No, restart the application
MOV AX, 6F02H
;disable
Watchdog
Timer
MOV BL, 0
;
INT 15H
;
;
EXIT
;