AFL2-12A-HM65 Series Panel PC
Page 124
NOTE:
When exiting a program it is necessary to disable the Watchdog Timer,
otherwise the system resets.
Example program:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
MOV AX, 6F02H
;setting the time-out value
MOV BX, 05
;time-out value is 5 seconds
INT 15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP EXIT_AP, 1
;is the application over?
JNE W_LOOP
;No, restart the application
MOV AX, 6F02H
;disable Watchdog Timer
MOV BX, 0
;
INT 15H
;
; EXIT ;
Содержание AFL2-12A-HM65/PC-R15
Страница 14: ......
Страница 15: ...AFL2 12A HM65 Series Panel PC Page 1 1 Introduction Chapter 1...
Страница 26: ...AFL2 12A HM65 Series Panel PC Page 12 2 Detailed Specifications Chapter 2...
Страница 33: ...AFL2 12A HM65 Series Panel PC Page 19 3 Unpacking Chapter 3...
Страница 38: ...AFL2 12A HM65 Series Panel PC Page 24 4 Installation Chapter 4...
Страница 64: ...AFL2 12A HM65 Series Panel PC Page 50 5 System Maintenance Chapter 5...
Страница 73: ...AFL2 12A HM65 Series Panel PC Page 59 6 AMI BIOS Setup Chapter 6...
Страница 108: ...AFL2 12A HM65 Series Panel PC Page 94 7 Software Drivers Chapter 7...
Страница 112: ...AFL2 12A HM65 Series Panel PC Page 98 Appendix A A Regulatory Compliance...
Страница 117: ...AFL2 12A HM65 Series Panel PC Page 103 Appendix B B Barebone Version Installation...
Страница 120: ...AFL2 12A HM65 Series Panel PC Page 106 Appendix C C Interface Connectors...
Страница 127: ...AFL2 12A HM65 Series Panel PC Page 113 Appendix D D Safety Precautions...
Страница 133: ...AFL2 12A HM65 Series Panel PC Page 119 Appendix E E BIOS Configuration Options...
Страница 136: ...AFL2 12A HM65 Series Panel PC Page 122 Appendix F F Watchdog Timer...
Страница 139: ...AFL2 12A HM65 Series Panel PC Page 125 Appendix G G Hazardous Materials Disclosure...