AFL-W19A/17D/W15A-N270 Panel PC
Page 111
NOTE:
When exiting a program it is necessary to disable the Watchdog Timer,
otherwise the system resets.
Example program:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
MOV
AX, 6F02H
;setting the time-out value
MOV
BL, 30
;time-out value is 48 seconds
INT
15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP
EXIT_AP, 1
;is the application over?
JNE
W_LOOP
;No, restart the application
MOV
AX, 6F02H
;disable Watchdog Timer
MOV
BL, 0
;
INT
15H
;
; EXIT ;
Содержание AFL-W15A-N270
Страница 12: ...AFL W19A 17D W15A N270 Panel PC Page 1 Chapter 1 1 Introduction...
Страница 19: ...AFL W19A 17D W15A N270 Panel PC Page 8 1 7 2 AFL 17D N270 Dimensions Figure 1 6 AFL 17D N270 Dimensions...
Страница 20: ...AFL W19A 17D W15A N270 Panel PC Page 9 1 7 3 AFL W19A N270 Dimensions Figure 1 7 AFL W19A N270 Dimensions...
Страница 21: ...AFL W19A 17D W15A N270 Panel PC Page 10 Chapter 2 2 Installation...
Страница 54: ...AFL W19A 17D W15A N270 Panel PC Page 43 Chapter 3 3 BIOS Setup...
Страница 99: ...AFL W19A 17D W15A N270 Panel PC Page 88 Chapter 4 4 System Maintenance...
Страница 102: ...AFL W19A 17D W15A N270 Panel PC Page 91 Figure 4 2 DDR SO DIMM Module Installation...
Страница 103: ...AFL W19A 17D W15A N270 Panel PC Page 92 Appendix A A Safety Precautions...
Страница 108: ...AFL W19A 17D W15A N270 Panel PC Page 97 Appendix B B ALC892 Digital Microphone Configuration...
Страница 112: ...AFL W19A 17D W15A N270 Panel PC Page 101 Appendix C C BIOS Options...
Страница 116: ...AFL W19A 17D W15A N270 Panel PC Page 105 Appendix D D Terminology...
Страница 120: ...AFL W19A 17D W15A N270 Panel PC Page 109 Appendix E E Watchdog Timer...
Страница 123: ...AFL W19A 17D W15A N270 Panel PC Page 112 Appendix F F Hazardous Materials Disclosure...