Cable Routing
For all moving cables, suitable cable routing has to be used to effectively prevent cable breaks. The
minimum radius r
min
for cable routing chains is calculated for IEF-Werner cables according to the
following formula:
r
min
≥
10 x cable diameter
When different cables are used, EN 60204 must be observed. In addition, it must be ensured that a
space reserve of 30% is kept free within the routing chains. A strain relief for the cables has to be
attached at the outlet of the cable routing chain.
We recommend purchasing genuine cables and energy chains from IEF-Werner GmbH. Please
contact us. We will gladly advise you.
4.4.4
Measuring System
Absolute measuring system EnDAT 2.2 (Heidenhain)
4.4.5
Temperature Sensor
PTC thermistor with the following characteristics:
Figure 13
Chart PTC
The resistance increases roughly linear with the temperature.
4.4.6
Installation Situation Measuring System
Figure 14
Distance measuring tape to measuring head
A
Measuring tape
B
Measuring head