![IED IED0520DTB Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/ied/ied0520dtb/ied0520dtb_installation-instructions-manual_619089004.webp)
PAGE
3
DOC: 374B
REV: 12-12
IEDA524-H / IEDA520DTB DIGITAL MICROPHONE STATION
INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
1.
Read these instructions.
2.
Keep these instructions.
3.
Heed all warnings.
4.
Follow all instructions.
5.
Do not use this apparatus near water.
6.
Clean only with dry cloth.
7.
Install in accordance with the manufacturer’s in-
structions.
8.
Do not install near any heat sources such as ra-
diators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
9.
Only use attachments/accessories specified by the
manufacturer.
10.
Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord
or plug is damaged, liquid has been spilled or ob-
jects have fallen into the apparatus, the apparatus
has been exposed to rain or moisture, does not
operate normally, or has been dropped.
SAFETY SYMBOLS
Labeling on products and the
Installation Instructions &
User Manual
may use safety related graphical symbols
as shown below to note safety requirements.
Lightning Bolt:
The lightning flash with
arrowhead symbol, within an equilateral triangle,
WARNING symbol, is intended to alert the user to
the presence of un-insulated
dangerous voltage
within the product’s enclosure that may be
sufficient in magnitude to constitute a risk of
electric shock to persons or domestic animals.
Exclamation Point:
The exclamation point
within an equilateral triangle, CAUTION symbol,
is in-tended to alert the user to the presence of
important operating and maintenance (servicing)
instructions, or a hazard that can damage equip-
ment.
Do not proceed beyond a WARNING or CAUTION notice
until you have understood the hazardous condition and
have taken appropriate steps.
SPECIFICATIONS
Electrical
Frequency Response .................................................................................... ±0.5 dB
22 Hz - 22 kHz, Input Level = 0 dBu
Total Harmonic Distortion, THD ....................................................................... <0.5%
22 Hz - 22 kHz, Input Level = 0 dBu
Signal-to-Noise Ratio, S/N .............................................................................. >85 dB
22 Hz - 22 kHz, Input Level = 0 dBu
Compressor
Compression Threshold ............................................................................–15 dBu
Ratio ...................................................................................................................5:1
Attack Time ...............................................................................................22 mSec
Release Time ..................................................................................................1 Sec
Maximum Output (Line Output) ...................................................................... +5 dBu
Analog-to-Digital Converter, A/D ......................................................................... 24 bit
Internal Processing .................................................................... 32 bit, Floating Point
Sample Rate .....................................................................................................48 kHz
Latency (Through a maximum of 6 network switch hops) ......................... 5.7 mSec
Mechanical
Desktop Size ......................................................................5.13” W x 5.32” H x 5.66”D
(Desktop mounting requires optional IEDA520DTB)
Wall Mount Size ..................................................................4.95” W x 4.95” H x 1.9” D
Wall Mount mounting ................................................................. 2-gang electrical box
1-gang electrical box (using adapter backbox)
Standards Utilized
Full-Duplex Operations ........................................................................... IEEE 802.3x
Fast Ethernet, 100Mbps .......................................................................... IEEE 802.3u
The 524 Series specifically uses 100Base-TX
Data Terminal Equipment Power ........................................................... IEEE 802.3af
via Media Dependent Interface (PoE)
Connecting Cable
Digital Audio/Power/Control ............................................................. CAT5e or better
For distances to a maximum of 100 Meters (approximately 300 feet) to the con-
nected switch. Cable installed and tested in accordance with ANSI/TIA/EIA 568B
Standards.
Environmental
Operating Temperature Range ............................
+32˚F to +104˚F (0˚C to +40˚C)
Storage Temperature Range .............................–40
˚
F to +158
˚
F (–40
˚
C to +70
˚
C)
Power
Consumption
Supply Power .......................................................................................................<2W
Supply Voltage = 48VDC
NOTE:
This unit is
not
compatible with 500, 510, or 520 series Announcement Control Systems (ACS).