IEDA520 / LC108 DIGITAL COMMUNICATION STATION

INSTALLATION

IEDA520W Base Unit Attached to IEDA520DTB Desktop Base

IEDA520DTB

IEDA520W Base Unit Attached to Standard Electrical Box

Standard 1-gang

electrical box

Содержание IEDA520

Страница 1: ...LC108 DIGITAL COMMUNICATION STATION REV 01 12 DOC 369B IEDA520 LC108MS IEDA520D IEDA520D G IEDA520W IEDA520W T IEDA520W H IEDA520DTB LC108MS D LC108MSD G LC108MSW HS LC108MSW HH DIGITAL COMMUNICATION...

Страница 2: ...tons The 520 series digital communication stations feature eight capacitive touch selection buttons each with an LED that lights when the button is active These buttons can be configured via the IED E...

Страница 3: ...ntercom communications 520 Model Numbers IEDA520D LC108MS D Desktop without microphone IEDA520D G LC108MSD G Desktop with gooseneck microphone IEDA520W Wall mount without microphone IEDA520W T LC108MS...

Страница 4: ...ons or domestic animals Exclamation Point The exclamation point within an equilateral triangle CAUTION symbol is in tended to alert the user to the presence of important operating and maintenance serv...

Страница 5: ...D GREEN Status LEDs are integrated into the logo Handset Headset Input RJ45 Ethernet Telephone Pass Through XLR for Gooseneck mic Pin 1 S Pin 2 Pin 3 Slot for button label card Announcement selection...

Страница 6: ...s between the two units Note that the telephone handset headset interface is only available in the desktop base units and not in the wall mount units Route microphone cord through this strain relief a...

Страница 7: ...ed handset input located inside the unit Due to this difference the IEDA520HS ships attached to the base unit Route microphone cord through this strain relief and secure with the included screw Microp...

Страница 8: ...ALLATION INSTRUCTIONS IEDA520 LC108 DIGITAL COMMUNICATION STATION INSTALLATION IEDA520W Base Unit Attached to IEDA520DTB Desktop Base IEDA520DTB IEDA520W Base Unit Attached to Standard Electrical Box...

Страница 9: ...ype Gooseneck Gooseneck Handset 20dB boost ON Enable Telephone Passthrough N A Enable Sidetone N A Hand Headset Power N A Configuration using IEDA520HS no telephone IEDA520W LC108MSW Base PoE Ethernet...

Страница 10: ...f unit Parameter Setting Mic Type Handheld Gooseneck Handset 20dB boost OFF Enable Telephone Passthrough N A Enable Sidetone N A Hand Headset Power N A Configuration using telephone handset and teleph...

Страница 11: ...ar for systems that utilize this feature Figure 1 shows the icon for the configuration utility application Figure 1 IED520CU Configuration Utility Icon Reset to default IP address The IP address of th...

Страница 12: ...on utility 1 Enter the IP address of the unit in the Current IP Address entry box Click the Default button if you know that the unit is set at the factory default IP address of 10 2 150 165 2 Select t...

Страница 13: ...ect Click this button to instruct the application to establish communications with the unit using the IP address currently shown in the Current IP Address field DHCP BootP This radio button will force...

Страница 14: ...HS handset microphone with speaker Typically this option should not be used when using an external telephone headset The headset pre amplifier or headset control unit typically will have its own gain...

Страница 15: ...et 520 Press this button to send a command to the unit and initiate a reset Set Properties Press this button to send the current settings from the configuration utility to the unit Depending on the se...

Страница 16: ...e Electronic Designs LLC Innovative Electronic Designs LLC 1 502 267 7436 phone 9701 Taylorsville Road 1 502 267 9070 fax Louisville KY 40299 USA www iedaudio com INSTALLATION INSTRUCTIONS IEDA520 LC1...