When setting several partial scan areas, please set the start position and effective lines ->
4 x n.
□
Total Lines
=
V blanking line number (33H fixed)
+
Partial Scan Effective line numbers
Note that “Sum total of partial effective line numbers (expect V blanking lines) <
1544
should be met.
□
Frame Rate
=
1 / (Total lines x Time for 1 line)
Time for 1 line = 12.242us(2Tap:85MHz) / 15.758us(2Tap:66MHz) / 11.394us(3Tap)
□
Example
Effective lines
Frame
Total Lines
Frame Rate
2Tap Base
Configuration 85MHz
2Tap Base
Configuration 66MHz
3Tap Base
Configuration
4H(min)
37H
2207fps
1715fps
2372fps
・
12H
45H
1815fps
1410fps
1950fps
・
100H
133H
614fps
477fps
659fps
・
400H
433H
188fps
146fps
202fps
・
800H
833H
98fps
76.1fps
105fps
・
1080H
1113H
73.3fps
57fps
78.8fps
・
1200H
1233H
66.2fps
51.4fps
71.1fps
・
1544H(max)
1577H
51.7fps
40.2fps
55.6fps