5.8.Fixed Trigger Shutter Mode
□
This is the mode to start exposure with external input trigger signals, and set the exposure time with serial
commands.
□
Delay time (Exposure Time Delay) from detecting trigger edge in the camera to starting exposure is as below.
(1)
Trigger Hsync Mode
OFF
:
0.15 us fixed
(2)
Trigeer Hsync Mode
ON
:
0.15 us + max1HD
・
2Tap Base Configuration 85Mz
0.15us
+ max 1HD (12.242us)
・
2Tap Base Configuration 66Mz
max 1HD (15.758us)
・
3Tap Base Configuration
max 1HD (11.394us)
□
Triggers can be accepted even when outputting video signals.
However, trigger signals for exposure to start the next video output prior to the completion of video transmission
for the prior video output signals can not be accepted.
□
Trigger input during exposure time should be ignored. (Refer to the below A)
(
Caution
)
Trigger Hsync Mode
is available : Change the function ->SAVE->Camera restart
TRIG IN
max1HD
0.15
us
Exposure OUT
(Trigger Hsync : OFF)
0.15
us
Exposure OUT
(Trigger Hsync : ON)
Effective Line : 1544H
~ ~
SP Out
(Exposure Out)
1
5
4
4
1
TRIG IN
LVAL Out
FVAL Out
Video Out
DVAL Out
~ ~
1
Exposure Time
(Trigger input ignore period)
Exposure Time Delay
(A)
~ ~
~ ~
~ ~
25H
~ ~
8H