B5U033000E
Page 19 of 54
Access
RW
PDO Mapping
No
Value Range
See value definition
Default Value
00h
Save Object
Yes
The EPC C1G2 (Class-1 Generation-2) parameters are managed through the OD
2202h.
Value Definition:
Sub-index 00h contains the number of valid object entries within the record. The
number of valid objects entries shall be the number of the general configuration
parameters. Its value is 13h.
Sub-index 01h to 13h contains a configuration parameter. An attempt to change
the value of the configuration parameter to any not supported value shall be
responded with the SDO abort transfer service (abort code: 06090030h). See
the
BLUEBOX
user manual for value definition details.
Parameter
Description
Range
Default
Inventory
Mode
How the reader does an inventory in ‘continuous’
mode.
Fast Multi Tag
Fast Single
Tag
Standard Multi
Tag
Standard
Single Tag
Standard Multi
Tag
R->T Link
Frequency
R->T Link Frequency as defined in EPC Class 1
Generation 2 protocol.
40 kHz
160 kHz
256 kHz
320 kHz
640 kHz
160 kHz
R->T Bit
Coding
R->T Bit coding as defined in EPC Class 1
Geneneration 2 protocol.
FM0
Miller 2
Miller 4
Miller 8
Miller 2
Q Selection
Algorithm
The Q selection algorithm used for setting the slot-
counter parameter as defined in EPC Class 1
Generation 2 protocol.
Dynamic
Fixed
Dynamic
Q Value
The Q value used in fixed Q selection algorithm or
the starting Q value used in dynamic Q selection
algorithm as defined in EPC Class 1 Generation 2
protocol.
0 … 15
3