FFQG112S December. 2016 Copyright IDTECK Co., Ltd.
Quick Installation Guide
3. Cable Color
Cable name
Color
Main Power(DC+12V)
Red
Power Ground(GND)
Black
Wiegand Data-0
Green
Wiegand Data-1
White
BARGATE
1)
Gray
HOLD Loop INPUT
2)
Blue
OTR INPUT
3)
Yellow
RS232_TX
Purple
RS232_RX
Brown
BOOT_INPUT
4)
Orange
1.
BARGATE output (a transistor output) that directly controls a car circuit breaker is used for
circuit breaker control relay operation. The maximum current drain rate is 1 Amps.
2.
HOLD input is used to force NEO RF245 to read a tag when loop sensor detects any
approaching vehicle. When a vehicle is detected, NC contact should be used, and the input
should also be disconnected from GND completely. In OTR mode, the reader will only output
tag ID (1 time).
CAUTION: Nothing should be connected to this input unless loop sensor is in use.
3.
OTR cable (yellow) is used to limit the reading time to 1 (OTR = One time reading).
4.
When BOOT_INPUT is connected to GND during firmware upgrade, the system changes into
applicable mode.
CAUTION: Nothing should be connected to this input during normal operation.