Bar Code Message Formatting Selections (Group C )
Scanned bar code data can be formatted with the addition of preambles,
postambles, and terminator characters. The settings below will augment
bar code data scanned by the Omni. A fully-formatted message block
reflects the following model:
{Preamble}{Code ID}{Data}{Terminator}{Postamble}
1. Enter BAR CODE MESSAGE FORMATTING SETUP MODE by typing
/E/D/FC
.
2. Press
<ENTER>
.
The reader should beep twice.
3. Type the two-character selection code for the feature you wish to
change.
4. Press
<ENTER>
.
The reader should beep twice.
5. Type the one-character code for the change you wish to make.
6. Press
<ENTER>
.
The reader should beep twice.
7. Save the change and exit the Bar Code Setup Mode by typing
CZ
.
8. Press
<ENTER>
.
The reader should beep four times.
Note: To review the group’s current setting(s), type CY<ENTER> while in the
setup mode. To reset the current setting(s) to its group default, type CX<ENTER>
while in Bar Code Setup Mode.
Bar Code Terminator Character
Enter and Line Feed, Enter, Line Feed, or None: For some applications, it
may be convenient to end a string of bar code scan data with a terminator
character. For example, with keyboard entry, it is common to have the
operator signify the end of the data input with the “Enter” keystroke. The
terminator character serves this function.
SELECTION CODE: C1
ENTER and Line Feed
A
ENTER
B
Line Feed
C
None
D
EXAMPLE:
To set the bar code terminator character to Line Feed, enter:
/E/D/FC<ENTER>C1<ENTER>C<ENTER>CZ<ENTER>
1 0
SELECTION CODE: B7
On
A
Off
B
Code ID Definition (Group I)
If the Code ID option is enabled in General Setup, the user can select the
character used to identify each symbology.
1. Enter CODE ID DEFINITION SETTINGS MODE by typing
/E/D/FI
.
2. Press
<ENTER>
.
The reader should beep twice.
3. Enter the characters in the left column to select the symbology.
4. Press
<ENTER>
.
The reader should beep twice.
5. Enter one character for the new ID.
a
UPC-A
Default = a
b
UPC-E
Default = b
c
EAN-8
Default = c
d
EAN-13
Default = d
e
Code 39
Default = e
f
Interleaved 2 of 5
Default = f
g
Industrial 2 of 5
Default = g
h
Code 128
Default = h
i
MSI/Plessey
Default = i
j
Codabar
Default = j
k
MSR Track 1
Default = k
l
MSR Track 2
Default = l
m
MSR Track 3
Default = m
n
Telepen
Default = n
6. Press <ENTER>.
The reader should beep twice.
7. Save the change and exit the group setup mode by entering
IZ<ENTER>.
The reader should beep four times.
Note: To review the group’s current setting(s), type IY<ENTER> while in the
Group Setup Mode. To reset the current setting(s) to its group default, type
IX<ENTER> while in the Group Setup Mode.
EXAMPLE:
To change Code ID for Code 128 from h to w, enter:
/E/D/FI<ENTER>h<ENTER>w<ENTER>IZ<ENTER>