Code ID
This command designates the bar code symbologies or magnetic stripe
tracks that will be accepted as valid.
SELECTION CODE: JC
UPC-A
a
UPC-E
b
EAN-8
c
EAN-13
d
Code 39
e
Interleaved 2 of 5
f
Industrial 2 of 5
g
Code 128
h
MSI/Plessey
i
Codabar
j
MSR Track 1
k
MSR Track 2
l
MSR Track 3
m
Telepen
n
EXAMPLE:
To designate UPC-A, Code 39, Codabar, and MSR Track 1 as the only
valid sources of data, enter:
/E/D/FJ<ENTER>JC<ENTER>a<ENTER>e<ENTER>j<ENTER>k<ENTER>
JZ<ENTER>
Set Length
Use this command to indicate a minimum and maximum number of
characters allowed for valid data. The first two digits set the minimum
length, and the second two digits set the maximum length. (This command
is optional.)
SELECTION CODE: JD
Two Digits for Minimum Length
Two Digits for Maximum Length
EXAMPLE:
To set the minimum number of characters at six, and the maximum at
twelve, enter:
/E/D/FJ<ENTER>JD<ENTER>0<ENTER>6<ENTER>1<ENTER>2<ENTER>
JZ<ENTER>
3 7
3 6
Data Editing Commands
1. Enter DATA EDITING mode by typing
/E/D/FJ
2. Press
<ENTER>
. The reader should beep twice.
3. Type the two-character selection code for the function you wish to
enable or set.
4. Press
<ENTER>
. The reader should beep twice.
5. Type the command you wish to enter.
6. Press
<ENTER>
. The reader should beep twice.
7. Continue to add commands to the data editing formula as desired.
8. Save the formula and exit the data editing mode by typing
JZ <ENTER>
. The reader should beep four times.
Note: JZ should only being entered at the end of the entire data editing formula,
not after each command. See examples page 41.
Data Editing On/Off
Use this command to turn the Data Editing function on or off.
SELECTION CODE: JA
Data Editing Off
0
Data Editing On
1
EXAMPLE:
To turn the Data Editing function on, enter:
/E/D/FJ<ENTER>JA<ENTER>1<ENTER>JZ<ENTER>
Unmatched Input Send/Do Not Send
This command enables or disables the transmission of data that does not
meet the restrictions of the data editing formula(s). When SEND ALL
DATA is selected, data that does not match any of the formulas will be
transmitted anyway, along with any preambles or postambles. When DO
NOT SEND is selected, unmatched data will not be sent.
SELECTION CODE: JB
If No Formula Matches Data,
0
Do Not Send Data
If No Formula Matches Data,
1
Send All Data