background image

Page  VI

Table of Contents

Message Interception & Pack

Introduction ..............................................................................................................................................

128

Message Interception ...............................................................................................................................

129

Programming 1D Intercept Option ...................................................................................................

130

Programming 2D Intercept Option ...................................................................................................

131

Message Pack ...........................................................................................................................................

132

Introduction .......................................................................................................................................

132

Normal Pack .....................................................................................................................................

132

Batch Programming

Introduction ..............................................................................................................................................

133

How to build a batch command ...............................................................................................................

134

Produce setting code ................................................................................................................................

135

Use batch setting code .............................................................................................................................

136

Appendix

Digit Code ................................................................................................................................................

137

Save and Abort .........................................................................................................................................

139

Factory Default List .................................................................................................................................

140

AIM ID List .............................................................................................................................................

145

Code ID List .............................................................................................................................................

146

Symbols ID Number ................................................................................................................................

147

Содержание 2DScan FX100

Страница 1: ...2DScan FX100 Barcode Scanner Scanner User s Manual 80108506 001 rev B ...

Страница 2: ...Dimensions of FX100 Unit 11 Programming the Engine Introduction 12 Code Programming 12 Command Programming 12 QuickSet Programming 12 Programming Notation 13 Code Programming On Off 14 Illumination 15 Aiming 16 Beep 17 Decoding Beep 17 Decoding Beep Type 17 Decoding Beep Volume 18 Power On Beep 18 Beep Denotation Beeper Definitions 18 Reading Mode 19 Reading Timeout and Delay 20 Sensitivity 21 Expo...

Страница 3: ...elay 37 Caps Lock 37 Convert Case 38 Emulate Numeric Keypad 39 USB DataPipe 40 USB COM Port Emulation 41 HID POS 42 Introduction 42 Access the Device in Your Program 43 Getting Scanned Data 43 VID and PID Table 43 Symbols Introduction 44 General Options 45 Disable Reading All 45 Enable Reading All 45 Enable Reading All 1D 45 Disable Reading All 1D 45 Enable Reading All 2D 46 Disable Reading All 2D...

Страница 4: ... 57 Check Digit 57 2 Digits Addenda Code 58 5 Digits Addenda Code 58 Transmit Default 0 59 Interleaved 2 of 5 60 Load Factory Default 60 Disable Enable Interleaved 2 of 5 60 Select Message Length 61 Check Digit 62 Specified Lengths 63 ITF 14 64 ITF 6 65 Matrix 2 of 5 66 Load Factory Default 66 Disable Enable Matrix 2 of 5 66 Select Message Length 67 Check Digit 68 Code 39 69 Load Factory Default 69...

Страница 5: ...83 Check Digit 84 ISBN 85 Load Factory Default 85 Enable Disable ISBN 85 Transmit 85 Industrial 25 86 Load Factory Default 86 Enable Disable Industrial 25 86 Select Message Length 87 Check Digit 88 Standard 25 89 Load Factory Default 89 Enable Disable Standard 25 89 Select Message Length 90 Check Digit 91 Plessey 92 Load Factory Default 92 Enable Disable Plessey 92 Select Message Length 93 Check D...

Страница 6: ...orward Backwrd Direction Data Matrix 111 Maxicode 112 Load Factory Default 112 Enable Disable Maxicode 112 Select Message Length 113 Chinese Sensible Code 114 Load Factory Default 114 Enable Disable Chinese Sensible Code 114 Select Message Length 115 OCR Introduction 116 Prefix Suffix Introduction 117 General Programming 118 Disable or Enable Prefix Suffix 118 Prefix Sequences 119 Disable or Enable Use...

Страница 7: ...0 Programming 2D Intercept Option 131 Message Pack 132 Introduction 132 Normal Pack 132 Batch Programming Introduction 133 How to build a batch command 134 Produce setting code 135 Use batch setting code 136 Appendix Digit Code 137 Save and Abort 139 Factory Default List 140 AIM ID List 145 Code ID List 146 Symbols ID Number 147 ...

Страница 8: ...Scanner Integration Guide provides general instructions for OEM integration Graphic Notations Tool Handy item for a task Attention Important subject to be aware of or to avoid Tips Helpful information about a topic or a feature Example Illustration of how to use a feature ...

Страница 9: ...idirectional imager capture decode and transfer 1D 2Dbarcode This chapter presents an overall picture of how to use FX100 step by step Please have an FX100 handy This chapter is recommended to general users maintenance personnel and software programmers ...

Страница 10: ...er for services Outline of FX100 The figure below shows major components of FX100 FX100 Outline Indicator Sensor Light Illumination Aiming Light Lens Note The scan window must be kept clean Improper maintenance will breach the limited warranty Avoid rough objects not to damage or scratch the window Use brush to remove the stain Use soft cloth cloth for glasses to clean Prohibit spraying towards the...

Страница 11: ...g Data Interface Pin Function Type Name 1 NC Null 2 NC Null 3 VCC P Power DC5V 4 TXD O Serial Port Output RS232 5 RXD I Serial Port Input RS232 6 NC Null 7 NC Null 8 GND P Ground 9 D IO USB Data Signal 10 D IO PIN 1 PIN 10 Cable Slot ...

Страница 12: ... connect to a Host to operate A Host can be PC POS or any intelligent terminal with at least one of the following communication ports USB RS232 or PS 2 USB 1 RS232 2 RS232 port on Host Please check the ports first to order the fitting cable USB port on Host ...

Страница 13: ...Page 7 Getting to Start Connecting with USB Cable Insert USB Cable RJ45 male head into FX100 cable slot 1 Insert USB Cable USB male head into Host s female USB connector 2 ...

Страница 14: ... Start Connecting with RS232 Cable Insert RS232 cable RJ45 male head into FX100 cable slot 1 Insert RS232 cable RS232 male head into Host s female RS232 connector 2 Connect RS232 cable and the mains with power adapter 3 ...

Страница 15: ...Zones 36 0 50 100 150 200 250 55mm PDF417 10mil 175mm 45mm Data Matrix 10mil 145mm 45mm QR Code 10mil 140mm 35mm Code39 10mil 170mm 55mm Code39 15mil 210mm 45mm Data Matrix 15mil 175mm 60mm PDF417 15mil 205mm 50mm QR Code 15mil 175mm ...

Страница 16: ...5 nm Light Intensity 320 LUX 130 mm Depth of Scan Field 35mm 210 mm Print Contrast Signal 30 Sensitivity Roll 360 0 Pitch and 0 Skew Pitch 60 0 Roll and 0 Skew Skew 60 0 Roll and 0 Pitch Mechanical Electricals Power Consumption 2 1W Voltage DC 5 0V Current Max 420 mA Working 260 mA Idle 1 mA Weight 70g Environment Operate Temperature 5 C 45 C Storage Temperature 40 C 60 C Humidity 5 95 non condens...

Страница 17: ...Page 11 Getting to Start Dimensions of FX100 Unit FX100 Top View Figure 1 50mm 60mm 26mm 12mm 10mm 9mm 36mm 11 7mm M3 machine skew ...

Страница 18: ...ng The Host can send the Pro CMD strings see the chapter of Software Interface to program the Engine In the following sections the Pro CMD strings will be included with the barcodes for Code Programming A fixture such as EVK3000 or other simplier circuit board could be used to program the Engines before they are installed into your equipments or systems Another alternative is to design the configura...

Страница 19: ... notation The first part of the notation is the barcode for Code Programming 1 The second part of the notation is the name of the options or features such as Disable Code Pro 2 gramming The third part of the notation is the corresponding Pro CMD string of the Code Programming 3 If there is in front of the name it means the notation is factory default 4 Code Programming OFF Pro CMD 0006000 1 2 3 4 ...

Страница 20: ...uch as digits they can be found at the end of this chapter To exit Code Programming read Code Programming OFF or any normal barcode Code Programming OFF Pro CMD 0006000 Code Programming ON Pro CMD 0006010 The value of code programming can be sent to the Host For factory default No Send Pro Code Value the value of programming codes will not be sent to the Host by reading Send Pro Code Value the rea...

Страница 21: ...capture better images There are 4 modes Illumination Wink LED keeps flashing when reading Illumination Keep ON LED keeps on when Power ON Illumination Read ON LED keeps on when reading Illumination OFF LED is off all the time Illumination Wink Pro CMD 0200000 Illumination Keep ON Pro CMD 0200010 Illumination Read ON Pro CMD 0200030 Illumination OFF Pro CMD 0200020 ...

Страница 22: ...ne Programming the Engine Code Programming ON Code Programming OFF Tools Aiming There are 3 modes Aim Wink LED keeps flashing when reading Aim Keep ON LED keeps on when Power ON Aim Wink Pro CMD 0201000 Aim Keep ON Pro CMD 0201010 ...

Страница 23: ...ng ON Code Programming OFF Tools Beep Decoding Beep Read Beep ON to enable all decoding beep denotation and read Beep OFF to disable Beep ON Pro CMD 0203010 Beep OFF Pro CMD 0203000 Decoding Beep Type Type 1 Pro CMD 0203020 Type 2 Pro CMD 0203021 Type 3 Pro CMD 0203022 ...

Страница 24: ...er higher Power ON completed 1 beep successful reading of an ordinary barcode 2 beeps successful reading of an programming barcode 3 short low 2 high reading failure 1 long low Unknown Character Virtual Keypad USB connection Decoding Beep Volume Loud Pro CMD 0203030 Medium Pro CMD 0203031 Low Pro CMD 0203032 Beep On Pro CMD 0204001 Beep OFF Pro CMD 0204000 Power On Beep ...

Страница 25: ... front of the engine auto matically initiates reading After completion of reading the engine goes to idle Both luminance change and the Trigger can initiate reading when idle Continuous Mode Pull the Trigger line low to start reading The engine will keep reading To stop pull trigger line low again Auto Mode Pro CMD 0302010 Continuous Mode Pro CMD 0302020 ...

Страница 26: ...s removed out of reading area and moved back Multi reading Semi prohibit Pro CMD 0313020 Multi reading Prohibit Pro CMD 0313030 To set One Reading Timeout to 1500ms read these programming codes Code Programming ON 1 One 2 Reading Timeout Digit Code 1 5 0 0 see Digit Code 3 Save Programming 4 One Reading Timeout If the engine doesn t read any barcode during the timeout period it will stop reading a...

Страница 27: ...hange Sensitivity value is 1 20 The lower the sensitivity value is the higher sensitivity will be The low er the sensitivity value is the smaller illumination change will initiate reading High Sensitivity 8 Pro CMD 0312020 Normal Sensitivity 11 Pro CMD 0312010 Low Sensitivity 14 Pro CMD 0312000 Enhanced Sensitivity 5 Pro CMD 0312030 Program Sensitivity Min 1 Max 20 Pro CMD 0312040 ...

Страница 28: ...age 22 Programming the Engine Programming the Engine Code Programming ON Code Programming OFF Tools Exposure Imaging Mode Normal Exposure Mode Pro CMD 0321000 Reflections Eliminating Mode Pro CMD 0321010 ...

Страница 29: ...vious programming and start over Load All Factory Default Pro CMD 0001000 User Default All user options can be saved as User Default It will be restored in non volatile memory Read Save as User Default to save all the current user options to be User Default and erase the previous User Default Read Load User Default to restore the engine to User Default Save as User Default Pro CMD 0001150 Load Use...

Страница 30: ...e Manufacture Date S N Device serial number ESN User defined device serial number Manufacture ID Device Name Interface 1 types of communication interfaces TTL232 EM3000 or RS232 EM2027 baud rate parity check data bits stop bit 1D Indicate that reading 1D is allowed Symbols are divided by comma Additional features format connect features 1 Min Message Length Max Message Length 2 No Check Digit or C...

Страница 31: ...ed to the Host with RS232 cable system will select RS232 connection by default Under RS232 connection the engine and the Host use the same communication parameters baud rate parity check data bits select and stop bits select Select RS232 Connection Pro CMD 1100000 ...

Страница 32: ...ommunicate The engine supports the following baud rates The default baud rate is 9600 9600 Pro CMD 0100030 1200 Pro CMD 0100000 2400 Pro CMD 0100010 4800 Pro CMD 0100020 14400 Pro CMD 0100040 19200 Pro CMD 0100050 38400 Pro CMD 0100060 57600 Pro CMD 0100070 115200 Pro CMD 0100080 The engine and the Host should use the same serial port parameters baud rate parity check data bits and stop bits The s...

Страница 33: ...n accordance with CTS signal level When it is low level CTS signal it means the serial port s cache memory of receiving end such as PC is full and the engine will not send data through RS232 until CTS signal is set to high level by receiving end When the engine is not ready for receiving it will set RTS signal to low level When sending end such as PC detects it it could not send data to the engine...

Страница 34: ...he selections on the engine and the Host are the same Stop Bits Stop bit follows every byte to indicate the end of transmission and the start of the next transmission Default 1 stop bit 1 Stop Bits Pro CMD 0102000 2 Stop Bits Pro CMD 0102010 Serial Port 8 Data Bits Pro CMD 0103030 7 Data Bits Pro CMD 0103020 6 Data Bits Pro CMD 0103010 5 Data Bits Pro CMD 0103000 ...

Страница 35: ...ough USB connection USB HID KBW option can be programmed It emulates the unit s transmission as a USB keyboard input The Host receives keystrokes of the virtual keyboard It is Plug and Play There is no driver required If a USB connection and an RS232 connection are used at the same time the engine will select USB connection by default for its priority ...

Страница 36: ... needed supports simulating the Imager transmission to be a USB keyboard input The Host receives keystrokes of the virtual keyboard It works in Plug and Play base There is no driver required Select USB HID KBW Pro CMD 1100020 If the input field of the Host allows keyboard input no software needed to assist HID KBW input ...

Страница 37: ...able USB Country Keyboard Types Follow the steps mentioned below to program Code Programming ON 1 Select Country Code 2 Read digit codes according to country code 3 Save programming 4 Code Programming OFF 5 Select Country Code Pro CMD 1103000 Emulate Norway keyboard 1 Code Programming ON 2 Select Country Code 3 Digit code 1 5 4 Save Programming 5 Code Programming OFF USB Country Keyboard Types ...

Страница 38: ...gium 1 Norway 15 Brazil 2 Poland 16 Canada French 3 Portugal 17 Czechoslovakia 4 Romania 18 Denmark 5 Russia 19 Finland Swedish 6 Slovakia 21 France 7 Spain 22 Germany Austria 8 Sweden 23 Greece 9 Switzerland German 24 Hungary 10 Turkey F 25 Israel Hebrew 11 Turkey Q 26 Italy 12 U K 27 Latin American 13 Japan 28 ...

Страница 39: ... It may not be able to allocate and send a keystroke thus lead to an error beep No Beep Unkown Character Pro CMD 1103030 Beep Unkown Character Pro CMD 1103031 Suppose select country keyboard types France number 7 read a barcode AÐF Since the Ð 0xD0 is not included in France country code the Imager skip Ð and transmit AF For factory default no beep produced Read Beep Unkown Character to indicate un...

Страница 40: ...tions ALT Make 1 According to the ASCII value input the numbers over the numeric keypad 2 ALT Break 3 No Emulate ALT keypad Pro CMD 1103060 Emulate ALT keypad Pro CMD 1103061 Too much keystroke emulation slows the sending speed Suppose country code 7 France is selected and Emulate ALT keypad is enabled Barcode message AÐF 65 208 70 will be sent as 1 ALT make 0 6 5 ALT Break 2 ALT make 2 0 8 ALT Br...

Страница 41: ... key 2 Ctrl Break 3 No Function Key Mapping Pro CMD 1103130 Function Key Mapping Pro CMD 1103140 USB HID KBW set to be factory default Enable Emulate CTRL keypad Read barcode A tab F 0x65 0x09 0x70 The sequence is 1 Keystroke A 2 Input Ctrl I by Ctrl make Keystroke I Ctrl break 3 Keystroke F For some text editors Ctrl I is italic convert So the output may be AF Enable Emulate ATL keypad will autom...

Страница 42: ...BW ASCII Function Key Mapping Table ASCII HEX Function key ASCII HEX Function Key 00 2 10 P 01 A 11 Q 02 B 12 R 03 C 13 S 04 D 14 T 05 E 15 U 06 F 16 V 07 G 17 W 08 H 18 X 09 I 19 Y 0A J 1A Z 0B K 1B 0C L 1C 0D M 1D 0E N 1E 6 0F O 1F ...

Страница 43: ...ssion of data No Delay Pro CMD 1103050 Short Delay 20ms Pro CMD 1103051 Long Delay 40ms Pro CMD 1103052 Caps Lock The case of the data is inverted regardless of the state of the Caps Lock key on the Host Lower case and upper case are converted correspondingly Disable Caps Lock Pro CMD 1103010 Enable Caps Lock Pro CMD 1103020 Convert Case Emulate ALT keypad and Function Key Mapping option prevails ...

Страница 44: ... Tools USB HID KBW Convert Case The Imager converts all barcode messages to the selected case No Case Conversion Pro CMD 1103040 Convert All to Upper Case Pro CMD 1103041 Convert All to Lower Case Pro CMD 1103042 Read Convert All to Lower Case Barcode message AbC is sent as abc ...

Страница 45: ...if Num Lock light off the output is function key instead of numbers Disable Emulate Numeric Keypad Pro CMD 1103110 Emulate Numeric Keypad Pro CMD 1103120 Check Num Lock light before use this function Enable Emulate ALT keypad will automatically disable this function Enable Emulate Number Keyboard and read the A4 5 barcode If Num Lock on the Host is ON the data received will be A4 5 If Num Lock is ...

Страница 46: ...F Tools USB DataPipe A driver has to be installed before using this protocol to communicate with reader The advantage of using this protocol is the fast data transmission Meanwhile the SDK can be easily integrated into the application system Select USB DataPipe Pro CMD 1100010 ...

Страница 47: ...ort is connected to Host serial port in order to receive data from scanner the model of imitating USB to RS232 has to be chosen Hence the engine and the Host must communicate at the same parameters and the parameters of real serial port and visual serial port must be the same Select USB COM Port Emulation Pro CMD 1100060 ...

Страница 48: ...w applications It can send up to 56 characters in a single USB report and is muchfaster than keyboard emulation Features HID based no custom driver required Much faster than keyboard emulation and traditional RS 232 Note HID POS does not require a custom driver installation However a HID interface on Windows 98 does Select HID POS Pro CMD 1100080 ...

Страница 49: ...ar code the device sends the following input report Bit Byte 7 6 5 4 3 2 1 0 0 Report ID 0x02 1 Length of the bar code field Decoded Data 2 57 Decoded Data 1 56 58 61 Reserved 1 4 62 Symbology Identifier or N C 0x00 63 Decode Data Continued VID and PID Table USB uses two numbers to identify a device and find the correct drivers The first is the VID Vendor ID assigned by the USB Implementers Forum The ...

Страница 50: ...he available symbols and provides the programming barcodes to enable disable them Disabling reading of the symbols which do not apply will improve reading performance The few abling reading of the symbols are the fast the engine will work Symbols ...

Страница 51: ...l Allow reading Programming Codes only Enable Reading All Enable Reading All Enable to read all symbols and Programming Codes Enable Reading All Pro CMD 0001020 Enable Reading All 1D Enable Reading All 1D Pro CMD 0001040 Disable Reading All 1D Disable Reading All 1D Pro CMD 0001030 Disable Reading All Pro CMD 0001010 ...

Страница 52: ...Page 46 Symbols Code Programming ON Code Programming OFF Tools General Options Enable Reading All 2D Enable Reading All 2D Pro CMD 0001060 Disable Reading All 2D Disable Reading All 2D Pro CMD 0001050 ...

Страница 53: ...OFF Tools Code 128 Load Factory Default Load Code 128 Factory Default Pro CMD 0400000 Enable Disable Code 128 Disable Code 128 Pro CMD 0400010 Enable Code 128 Pro CMD 0400020 When the engine can not read Code 128 please read Enable Code 128 and try again ...

Страница 54: ... It is used to program the valid reading length of Code 128 The engine will not send barcode message to the Host if the decoded data length does not match the valid length Code 128 Message Length is defined by Min Message Length and Max Message Length Min Message Length default 1 Pro CMD 0400030 Max Message Length default 48 Pro CMD 0400040 1D bar code Message Length should not exceed 127 bytes If ...

Страница 55: ...t Load UCC EAN 8 Factory Default Pro CMD 0401000 Enable Disable UCC EAN 8 Enable UCC EAN 8 Pro CMD 0401020 Disable UCC EAN 8 Pro CMD 0401010 Check Digit UCC EAN 8 is fixed 8 digits barcode and the last digit is check digit Transmit Check Pro CMD 0401040 Do Not Transmit Check Pro CMD 0401030 ...

Страница 56: ...Digits Addenda Code 5 Digits Addenda Code is the one to the right of an ordinary code Picture below shows an ordinary code with a 5 digits Addenda Code The left one in blue lines is an ordinary code The right one in red lines is the 5 digits Addenda Code Disable 5 Digits Addenda Code Pro CMD 0401070 Enable5 Digits Addenda Code Pro CMD 0401080 Enable 2 Digits Addenda Code read an ordinary code and ...

Страница 57: ...e Programming ON Code Programming OFF Tools EAN 8 EAN 8 expand to EAN 13 Expand EAN 8 to EAN 13 by adding 5 bytes of 0 to the left and then transmit Do Not Expand to EAN 13 Pro CMD 0401090 Expand to EAN 13 Pro CMD 0401100 ...

Страница 58: ...ming OFF Tools EAN 13 Load Factory Default Load EAN 13 Factory Default Pro CMD 0402000 Disable EnableEAN 13 Enable EAN 13 Pro CMD 0402020 Disable EAN 13 Pro CMD 0402010 Check Digit Transmit Check Pro CMD 0402040 Do Not Transmit Check Pro CMD 0402030 ...

Страница 59: ...icture below shows an ordinary code with a 5 digits Addenda Code The left one in blue lines is an ordinary code The right one in red lines is the 5 digits Addenda Code Addenda Code is the one to the right of an ordinary code Picture below shows an ordinary code with a 2 digits Addenda Code The left one in blue lines is an ordinary code The right one in red lines is the 2 digits Addenda Code Disabl...

Страница 60: ...t Pro CMD 0403000 Disable Enable UPC E Enable UPC E Pro CMD 0403020 Disable UPC E Pro CMD 0403010 When the engine can not read UPC E please read Enable UPC E and try again Check Digit UPC E is fixed 8 digits barcode and the last digit is check digit Transmit Check Pro CMD 0403040 Do Not Transmit Check Pro CMD 0403030 ...

Страница 61: ...its Addenda Code Pro CMD 0403080 5 Digits Addenda Code is the one to the right of an ordinary code Picture below shows an ordinary code with a 5 digits Addenda Code The left one in blue lines is an ordinary code The right one in red lines is the 5 digits Addenda Code Abort 2 Digits Addenda Pro CMD 0403050 Enable 2 Digits Addenda Code Pro CMD 0403060 Addenda Code is the one to the right of an ordin...

Страница 62: ...E Transmit Default 0 The first byte of UPC E is default to 0 UPC E Expand to UPC A Follow the standard algorithm to expand UPC E to UPC A Do Not Expand to UPC A Pro CMD 0403110 Expand to UPC A Pro CMD 0403120 Do Not Transmit 0 Pro CMD 0403090 Transmit 0 Pro CMD 0403100 ...

Страница 63: ... Pro CMD 0404000 Disable Enable UPC A When the engine can not read UPC A please read Enable UPC A and try again Check Digit UPC A is fixed 13 digits barcode and the last digit is Check Digit Enable UPC A Pro CMD 0404020 Disable UPC A Pro CMD 0404010 Transmit Check Pro CMD 0404040 Do Not Transmit Check Pro CMD 0404030 ...

Страница 64: ...nda Code Pro CMD 0404080 5 Digits Addenda Code is the one to the right of an ordinary code Picture below shows an ordinary code with a 5 digits Addenda Code The left one in blue lines is an ordinary code The right one in red lines is the 5 digits Addenda Code Disable 2 Digits Addenda Code Pro CMD 0404050 Enable 2 Digits Addenda Code Pro CMD 0404060 Addenda Code is the one to the right of an ordina...

Страница 65: ...ramming OFF Tools Transmit Default 0 The first byte of UPC A is default to 0 UPC A has the default 0 but it is not printed out unlike UPC E Read Transmit 0 will add a 0 to transmit UPC A Do Not Transmit 0 Pro CMD 0404090 Transmit 0 Pro CMD 0404100 ...

Страница 66: ...actory Default Load Interleaved 2 of 5 Factory Default Pro CMD 0405000 Disable Enable Interleaved 2 of 5 When the engine can not read Interleaved 2 of 5 please read Enable Interleaved 2 of 5 and try again Enable Interleaved 2 of 5 Pro CMD 0405020 Disable Interleaved 2 of 5 Pro CMD 0405010 ...

Страница 67: ...h as 12 bytes read these programming codes 1 Code Programming ON 2 Select Min Message Length 3 Digit Code 8 see Digit Code Appendix Pxxx 4 Save Programming see Digit Code Appendix Pxxx 5 Select Max Message Length 6 Digit Code 1 7 Digit Code 2 8 Save Programming 9 Code Programming OFF Min Message Length default 6 Pro CMD 0405030 Max Message Length default 80 Pro CMD 0405040 1D bar code Message Leng...

Страница 68: ...k If verification is successful transmits all messages if not engine will not send barcode mes sage to the Host NO Check Transmit All Pro CMD 0405050 When Check Do Not Transmit Check digit is enabled and barcode message length minus one is less than Min Message Length it will lead to an error E g Reading a 4 byte include check Digit Interleaved 2 of 5 with the Min Message Length being 4 bytes and C...

Страница 69: ... only read Interleaved 2 of 5 which are 12 and 24 bytes 1 Code Programming ON 2 Enable Specified Length 3 Add Code Length 4 Digit Code 0 1 2 5 Save Programming 6 Add code length 7 Digit Code 0 2 4 8 Save Programming 9 Code Programming OFF The engine only read Interleaved 2 of 5 between 12 bytes and 24 bytes 1 Code Programming ON 2 Enable Specified Length 3 Add Code Length 4 Digit Code 0 1 2 5 Digi...

Страница 70: ...When enabled ITF 14 precedes 14 byte Interleaved 2 of 5 barcode Disable ITF 14 Pro CMD 0405080 Enable ITF 14 Do Not Transmit Check Digit Pro CMD 0405090 Enable ITF 14 Transmit Check Digit Pro CMD 0405100 For instance when ITF 14 is enabled and Interleaved 2 of 5 is disabled the ITF 14 and 14 bytes Interleaved 2 of 5 with check digit can be read but other Interleaved 2 of 5 can not ...

Страница 71: ...recedes 6 byte Interleaved 2 of 5 barcode Disable ITF 6 User Selection Pro CMD 0405110 ITF 6 Read Do Not Transmit Check Digit Pro CMD 0405120 ITF 6 Read Transmit Check Digit Pro CMD 0405130 For instance when ITF 6 is enabled and Interleaved 2 of 5 is disabled the ITF 6 and 6 bytes Interleaved 2 of 5 with check digit can be read but other Interleaved 2 of 5 can not ...

Страница 72: ...5 Load Matrix 2 of 5 Factory Default Pro CMD 0406000 Disable Enable Matrix 2 of 5 Enable Matrix 2 of 5 Pro CMD 0406020 Disable Matrix 2 of 5 Pro CMD 0406010 Load Factory Default When the engine can not read Interleaved 2 of 5 please read Enable Interleaved 2 of 5 and try again ...

Страница 73: ...ngth To set Min Message Length of Matrix 2 of 5 as 8 bytes and Max Message length as 12 bytes read these programming codes 1 Code Programming ON 2 Select Min Message Length 3 Digit Code 8 see Digit Code Appendix Pxxx 4 Save Programming see Digit Code Appendix Pxxx 5 Select Max Message Length 6 Digit Code 1 7 Digit Code 2 8 Save Programming 9 Code Programming OFF 1D bar code Message Length should n...

Страница 74: ...transmits barcode message if not engine will not send barcode message to the Host Check Transmit All means to read and check If verification is successful transmits all messages if not engine will not send barcode mes sage to the Host When Check Do Not Transmit Check digit is enabled and barcode message length minus one is less than Min Message Length it will lead to an error E g Reading a 4 byte i...

Страница 75: ... Default Pro CMD 0408000 Enable Disable Code 39 When the engine can not read Code 39 please read Enable Code 39 and try again Transmit Start Stop Character Transmission of can be selected Enable Code 39 Pro CMD 0408020 Disable Code 39 Pro CMD 0408010 Transmit Both Pro CMD 0408090 Transmit Neither Pro CMD 0408080 ...

Страница 76: ...bytes read these programming codes 1 Code Programming ON 2 Select Min Message Length 3 Digit Code 8 see Digit Code 4 Save Programming see Digit Code 5 Select Max Message Length 6 Digit Code 1 7 Digit Code 2 8 Save Programming 9 Code Programming OFF Min Message Length default 1 Pro CMD 0408030 Max Message Length default 48 Pro CMD 0408040 1D bar code Message Length should not exceed 127 bytes If Ma...

Страница 77: ...ck Transmit All Pro CMD 0408050 Check Do not transmit Check Digit Pro CMD 0408060 Check Transmit All Pro CMD 0408070 Check Digit Code 39 may include Check Digit not compulsory following its barcode message It verifies the barcode message NO Check Transmit All means to read without check and transmit all bytes including barcode message and Check Digit Check Do Not Transmit Check Digit means to read ...

Страница 78: ...ing OFF Tools Codabar Load Factory Default Load Codabar Factory Default Pro CMD 0409000 Enable Disable Codabar When the engine can not read Codabar please read Enable Codabar and try again Enable Codabar Pro CMD 0409020 Disable Codabar Pro CMD 0409010 ...

Страница 79: ... length Codabar Message Length is defined by Min Message Length and Max Message Length Min Message Length default 2 Pro CMD 0409030 Max Message Length default 60 Pro CMD 0409040 1D bar code Message Length should not exceed 127 bytes If Max Message Length is less than Min Message Length it means the engine will only support barcodes of the two lengths If Max Message Length is equal to Min Message Le...

Страница 80: ...nsmit Check Digit Pro CMD 0409060 Check Transmit All Pro CMD 0409070 Check Digit Codabar may include Check Digit not compulsory following its barcode message It verifies the barcode message NO Check Transmit All means to read without check and transmit all bytes including barcode message and Check Digit Check Do Not Transmit Check Digit means to read and check If verification is successful transmits...

Страница 81: ...rt character and the stop character Transmission of them can be selected Transmit Both Start Stop Character Pro CMD 0409090 Transmit Neither Start Stop Character Pro CMD 0409080 Use ABCD ABCD As Start Stop Character Pro CMD 0409100 Use ABCD TN E As Start Stop Character Pro CMD 0409110 Use Upper Letter Pro CMD 0409120 Use Lower Letter Pro CMD 0409130 ...

Страница 82: ...ing OFF Tools Code 93 Load Factory Default Load Code 93 Factory Default Pro CMD 0410000 Enable Disable Code 93 When the engine can not read Code 93 please read Enable Code 93 and try again Disable Code 93 Pro CMD 0410010 Enable Code 93 Pro CMD 0410020 ...

Страница 83: ...bytes read these programming codes 1 Code Programming ON 2 Select Min Message Length 3 Digit Code 8 see Digit Code 4 Save Programming see Digit Code 5 Select Max Message Length 6 Digit Code 1 7 Digit Code 2 8 Save Programming 9 Code Programming OFF Min Message Length default 1 Pro CMD 0410030 Max Message Length default 48 Pro CMD 0410040 1D bar code Message Length should not exceed 127 bytes If Ma...

Страница 84: ...Check Digits Check Do Not Transmit Check Digit means to read and check If verification is successful transmits barcode message if not engine will not send barcode message to the Host Check Transmit All means to read and check If verification is suc cessful transmits all messages if not engine will not send barcode message to the Host When Check Do not Transmit Check digit is enabled and barcode mess...

Страница 85: ...UCC EAN 128 Load Factory Default Load UCC EAN 128 Factory Default Pro CMD 0412000 Enable Disable UCC EAN 128 When the engine can not read UCC EAN 128 please read Enable UCC EAN 128 and try again Enable UCC EAN 128 Pro CMD 0412020 Disable UCC EAN 128 Pro CMD 0412010 ...

Страница 86: ... Default Pro CMD 0413000 Enable Disable GS1 Databar When the engine can not read GS1 Databar please read Enable GS1 Databar and try again Enable GS1 Databar Pro CMD 0413020 Disable GS1 Databar Pro CMD 0413010 Transmit AI 01 Character Transmit AI 01 Character Pro CMD 0413060 Do not Transmit AI 01 Character Pro CMD 0413050 ...

Страница 87: ...actory Default Pro CMD 0414000 Enable Disable EAN UCC Composite When the engine can not read EAN UCC Composite please read Enable EAN UCC Composite and try again Enable EAN UCC Composite Pro CMD 0414020 Disable EAN UCC Composite Pro CMD 0414010 Enable UPC EAN Composite Pro CMD 0414040 Disable UPC EAN Composite Pro CMD 0414030 ...

Страница 88: ...ing OFF Tools Code 11 Load Factory Default Load Code 11 Factory Default Pro CMD 0415000 Enable Disable Code 11 When the engine can not read Code 11 please read Enable Code 11 and try again Enable Code 11 Pro CMD 0415020 Disable Code 11 Pro CMD 0415010 ...

Страница 89: ...ytes read these programming codes 1 Code Programming ON 2 Select Min Message Length 3 Digit Code 8 see Digit Code 4 Save Programming see Digit Code 5 Select Max Message Length 6 Digit Code 1 7 Digit Code 2 8 Save Programming 9 Code Programming OFF Min Message Length default 4 Pro CMD 0415030 Max Message Length default 48 Pro CMD 0415040 1D bar code Message Length should not exceed 127 bytes If Max...

Страница 90: ...Double Check Digits MOD11 MOD11 Len 10 Pro CMD 0415090 Single Check Digit MOD11 Len 10 Double Check Digits MOD11 MOD9 Len 10 Pro CMD 0415100 Do not transmit Check Digit Pro CMD 0415110 Transmit Check Digit Pro CMD 0415120 Check Digit Code 11 may include Check Digit not compulsory following its barcode message It verifies the barcode message NO Check Transmit All means to read without check and tran...

Страница 91: ...ry Default Load ISBN Factory Default Pro CMD 0416000 Enable Disable ISBN Enable ISBN Pro CMD 0416020 Disable ISBN Pro CMD 0416010 Transmit 13 digits Pro CMD 0416030 Transmit 10 digits Pro CMD 0416040 Transmit When the engine can not read ISBN please read Enable ISBN and try again ...

Страница 92: ...ial 25 Load Factory Default Load Industrial 25 Factory Default Pro CMD 0417000 Enable Disable Industrial 25 Enable Industrial 25 Pro CMD 0417020 Disable Industrial 25 Pro CMD 0417010 When the engine can not read Industrial 25 please read Enable Industrial 25 and try again ...

Страница 93: ...ill only sup port barcodes of the length It is used to program the valid reading length of Industrial 25 The engine will not send barcode message to the Host if the decoded data length does not match the valid length Industrial 25 Message Length is defined by Min Message Length and Max Message Length To set Min Message Length of Industrial 25 to 8 bytes and Max Message Length to 12 bytes read these...

Страница 94: ...ck Digit Check Do Not Transmit Check Digit means to read and check If verifica tion is successful transmits barcode message if not engine will not send barcode message to the Host Check Transmit All means to read and check If verification is successful transmits all messages if not engine will not send barcode message to the Host When Check Do not Transmit Check digit is enabled and barcode message ...

Страница 95: ...Standard 25 Load Factory Default Load Standard 25 Factory Default Pro CMD 0418000 Enable Disable Standard 25 When the engine can not read Standard 25 please read Enable Standard 25 and try again Enable Standard 25 Pro CMD 0418020 Disable Standard 25 Pro CMD 0418010 ...

Страница 96: ... will only sup port barcodes of the length It is used to program the valid reading length of Standard 25 The engine will not send barcode message to the Host if the decoded data length does not match the valid length Standard 25 Message Length is defined by Min Message Length and Max Message Length To set Min Message Length of Standard 25 to 8 bytes and Max Message Length to 12 bytes read these pro...

Страница 97: ...4 bytes and Check Do not transmit Check Digit enabled leads to an error Check Digit Standard 25 may include Check Digit not compulsory following its barcode message It verifies the barcode message NO Check Transmit All means to read without check and transmit all bytes including barcode message and Check Digit Check Do Not Transmit Check Digit means to read and check If verifica tion is successful t...

Страница 98: ...ing OFF Tools Plessey Load Factory Default Load Plessey Factory Default Pro CMD 0419000 Enable Disable Plessey Enable Plessey Pro CMD 0419020 Disable Plessey Pro CMD 0419010 When the engine can not read Plessey please read Enable Plessey and try again ...

Страница 99: ...gine will only sup port barcodes of the length It is used to program the valid reading length of Plessey The engine will not send barcode message to the Host if the decoded data length does not match the valid length Plessey Message Length is defined by Min Message Length and Max Message Length To set Min Message Length of Plessey to 8 bytes and Max Message Length to 12 bytes read these programming...

Страница 100: ...Check Digits Check Do Not Transmit Check Digit means to read and check If verifica tion is successful transmits barcode message if not engine will not send barcode message to the Host Check Transmit All means to read and check If verification is successful transmits all messages if not engine will not send barcode message to the Host When Check Do not Transmit Check digit is enabled and barcode mess...

Страница 101: ...MSI Plessey Load Factory Default Load MSI Plessey Factory Default Pro CMD 0420000 Enable Disable MSI Plessey Enable MSI Plessey Pro CMD 0420020 Disable MSI Plessey Pro CMD 0420010 When the engine can not read MSI Plessey please read Enable MSI Plessey and try again ...

Страница 102: ... will only sup port barcodes of the length It is used to program the valid reading length of MSI Plessey The engine will not send barcode message to the Host if the decoded data length does not match the valid length MSI Plessey Message Length is defined by Min Message Length and Max Message Length To set Min Message Length of MSI Plessey to 8 bytes and Max Message Length to 12 bytes read these pro...

Страница 103: ...nsmit Check digit is enabled and barcode message length minus one is less than Min Message Length it will lead to an error E g Reading a 4 byte include check byte MSI Plessey with the Min Message Length being 4 bytes and Check Do not transmit Check Digit enabled leads to an error Check Digit Plessey may include Check Digits s not compulsory following its barcode message It may have one or two digi...

Страница 104: ...rogramming OFF Tools PDF417 Load Factory Default Load PDF417 Factory Pro CMD 0501000 Enable Disable PDF417 Enable PDF417 Pro CMD 0501020 Disable PDF417 Pro CMD 0501010 When the engine can not read PDF417 please read Enable PDF417 and try again ...

Страница 105: ...t exceed 65535 bytes Max Message Length should not be less than Min Message Length To read a fixed length PDF417 Please program Max Min Message Length to the same value To set Min Message Length of PDF417 to 8 bytes and Max Message Length to 12 bytes read these programming codes 1 Code Programming ON 2 Select Min Message Length 3 Digit Code 8 see Digit Code 4 Save Programming see Digit Code 5 Selec...

Страница 106: ...17 Twin Code Single PDF417 Only Read either PDF417 code Twin PDF417 Only Read both PDF417 codes The transmission sequence is left upper PDF417 code followed by right lower PDF417 code Both Single Twin Read both PDF417 codes If successful transmit as twin PDF417 only Otherwise try single PDF417 only Forward Backwrd Direction PDF 417 Forward Direction Barcode Only Pro CMD 0501320 Backwrd Direction B...

Страница 107: ...ing OFF Tools QR Code Load Factory Default Load QR Code Factory Default Pro CMD 0502000 Enable Disable QR Code When the engine can not read QR Code please read Enable QR Code and try again Enable QR Code Pro CMD 0502020 Disable QR Code Pro CMD 0502010 ...

Страница 108: ...ceed 65535 bytes Max Message Length should not be less than Min Message Length To read a fixed length QR Code Please program Max Min Message Length to the same value To set Min Message Length of QR Code to 8 bytes and Max Message Length to 12 bytes read these programming codes 1 Code Programming ON 2 Select Min Message Length 3 Digit Code 8 see Digit Code 4 Save Programming see Digit Code 5 Select ...

Страница 109: ...between them must be short There are 3 options for reading QR twin code QR Twin Code Single QR Only Read either QR code Twin QR Only Read both QR codes The transmission sequence is left up per QR code followed by right lower QR code Both Single Twin Read both QR codes If successful transmit as twin QR only Otherwise try single QR only Single QR Only Pro CMD 0502070 Both Single Twin Pro CMD 0502090...

Страница 110: ...rogramming OFF Tools Aztec Load Factory Default Load Aztec Factory Default Pro CMD 0503000 Enable Disable Aztec When the engine can not read Aztec please read Enable Aztec and try again Enable Aztec Pro CMD 0503020 Disable Aztec Pro CMD 0503010 ...

Страница 111: ...eed 65535 bytes Max Message Length should not be less than Min Message Length To read a fixed length Aztec Please program Max Min Message Length to the same value To set Min Message Length of Aztec to 8 bytes and Max Message Length to 12 bytes read these programming codes 1 Code Programming ON 2 Select Min Message Length 3 Digit Code 8 see Digit Code 4 Save Programming see Digit Code 5 Select Max M...

Страница 112: ... Multi barcodes of an Image Mode 1 Pro CMD 0503070 Mode 2 Pro CMD 0503080 Mode 3 Pro CMD 0503090 There are three modes Mode 1 Read one barcode only Mode 2 Read fixed number of barcodes only Mode 3 Composite Reading Read fixed number of barcodes first if failed read one barcode only ...

Страница 113: ...e Programming ON Code Programming OFF Tools Aztec The number of Multi barcodes 1 Pro CMD 0503060 2 Pro CMD 0503061 3 Pro CMD 0503062 4 Pro CMD 0503063 5 Pro CMD 0503064 6 Pro CMD 0503065 7 Pro CMD 0503066 8 Pro CMD 0503067 ...

Страница 114: ...Data Matrix Load Factory Default Load Data Matrix Factory Default Pro CMD 0504000 Enable Disable Data Matrix When the engine can not read Data Matrix please read Enable Data Matrix and try again Enable Data Matrix Pro CMD 0504020 Disable Data Matrix Pro CMD 0504010 ...

Страница 115: ...not exceed 65535 bytes Max Message Length should not be less than Min Message Length To read a fixed length Data Matrix Please program Max Min Message Length to the same value To set Min Message Length of Data Matrix to 8 bytes and Max Message Length to 12 bytes read these programming codes 1 Code Programming ON 2 Select Min Message Length 3 Digit Code 8 see Digit Code 4 Save Programming see Digit ...

Страница 116: ... There are 3 options for reading Data Matrix Data Matrix Twin Code Single Data Matrix Only Read either Data Matrix Twin Data Matrix Only Read both Data Matrix The transmission sequence is left upper Data Matrix followed by right lower Data Matrix Both Single Twin Read both Data Matrix If successful transmit as twin Data Matrix Otherwise try single Data Matrix only Single Data Matrix Only Pro CMD 0...

Страница 117: ...odels in length and width 10 10 12 12 144 144 Rectangular symbols which has different amounts of models in length and width 6 16 6 14 14 22 Forward Direction Barcode Only Pro CMD 0504320 Backwrd Direction Barcode Pro CMD 0504321 Both Pro CMD 0504322 Forward Backwrd Direction Data Matrix Data Matrix has forward or backwrd direction Forward Direction Barcode Light colour ground Deep colour bars Back...

Страница 118: ... OFF Tools Maxicode Load Maxicode Factory Default Pro CMD 0505000 Enable Disable Maxicode When the engine can not read Maxicode please read Enable Maxicode and try again Enable Maxicode Pro CMD 0505020 Disable Maxicode Pro CMD 0505010 Load Factory Default ...

Страница 119: ...h is defined by Min Message Length and Max Message Length 2D bar code Message Length should not exceed 65535 bytes Max Message Length should not be less than Min Message Length To read a fixed length Maxicode Please program Max Min Message Length to the same value To set Min Message Length of Maxicode to 8 bytes and Max Message Length to 12 bytes read these programming codes 1 Code Programming ON 2 ...

Страница 120: ...hinese Sensible Code Factory Default Pro CMD 0508000 Enable Chinese Sensible Code Pro CMD 0508020 Disable Chinese Sensible Code Pro CMD 0508010 Enable Disable Chinese Sensible Code Load Factory Default When the engine can not read Maxicode please read Enable Chinese Sensible Code and try again ...

Страница 121: ...e Length is defined by Min Message Length and Max Message Length 2D bar code Message Length should not exceed 65535 bytes Max Message Length should not be less than Min Message Length To read a fixed length Maxicode Please program Max Min Message Length to the same value To set Min Message Length of Chinese Sensible Code to 8 bytes and Max Message Length to 12 bytes read these programming codes 1 Co...

Страница 122: ...ne supports OCR B standard and specific typefaces such as Disable OCR Pro CMD 0600010 Enable OCR Pro CMD 0600020 Introduction Load SPEC_OCR_B Factory Default Pro CMD 0600000 0 1 2 3 4 5 6 7 8 1 Nine numbers of OCR B typeface must be included 2 There must be a space between No 7 and No 8 number 3 It must start and end with There must be a space between and a number ...

Страница 123: ...d should not have all the information we need such as barcode type date and time of scan delimiter and so on in order to keep the code short and flexible Prefix and Suffix are how to fulfill the needs mentioned above They can be added removed and modified while the original barcode message is still in tact Barcode processing sequences 1 Intercept barcode message 2 Add Prefix Suffix 3 Pack 4 Terminate wit...

Страница 124: ... Disable or Enable Prefix Suffix Disable All Prefix Suffix Transmit barcode message with no Prefix Suffix Enable All Prefix Suffix Allow appending Code ID prefix AIM prefix User prefix User suffix and Terminal to the barcode message Disable All Prefix Suffix Pro CMD 0311000 Enable All Prefix Suffix Pro CMD 0311010 ...

Страница 125: ...l Programming Prefix Sequences 6 options of Prefix Sequences CodeID AIM User Prefix Pro CMD 0317000 CodeID User Prefix AIM Pro CMD 0317010 AIM CodeID User Prefix Pro CMD 0317020 AIM User Prefix CodeID Pro CMD 0317030 User Prefix CodeID AIM Pro CMD 0317040 User Prefix AIM CodeID Pro CMD 0317050 ...

Страница 126: ...The user prefix byte is programmed in its hex values See example below Note The maximum length for user prefix is 10 bytes Program User Prefix Pro CMD 0300000 Program CODE as user prefix The hex of CODE are 0x43 0x4F 0x44 0x45 1 Read Code Programming ON 2 Read Program User Prefix 3 Read 4 3 4 F 4 4 4 5 in order 4 Read Save Programming 5 Read Code Programming OFF 6 Read Allow User Prefix to enable abo...

Страница 127: ...g OFF Tools AIM Prefix AIM Automatic Identification Manufactures defines AIM prefix for many standard barcode formats AIM Prefix Format AIM prefix 0 Disable AIM Prefix for All Barcodes Pro CMD 0308000 Enable AIM Prefix for All Barcodes Pro CMD 0308030 AIM ID is not customizable ...

Страница 128: ...sides AIM prefix Code ID prefix can be used to denote barcode format and can be customized The Code ID prefix MUST be one 1 or two 2 visible English letters No Code ID Prefix Pro CMD 0307000 Allow Code ID Prefix Pro CMD 0307010 Code ID Default All Bar codes Load Code ID Factory Default Pro CMD 0307020 ...

Страница 129: ...OFF Code ID Prefix Modify Code ID See the examples below for how to modify a code ID and restore factory default code ID Load Code ID factory default including PDF417 1 Read Code Programming ON 2 Read 2D Load Code ID Factory Default 3 Read Code Programming OFF Modify PDF417 Pro CMD 0005000 Modify QR Code Pro CMD 0005010 Modify Aztec Pro CMD 0005020 Modify Data Matrix Pro CMD 0005030 Modify Maxicode...

Страница 130: ...EAN 8 Pro CMD 0004040 Modify EAN 13 Pro CMD 0004050 Modify UPC E Pro CMD 0004060 Modify UPC A Pro CMD 0004070 Modify Interleaved 2 of 5 Pro CMD 0004080 Modify ITF 14 Pro CMD 0004090 Modify ITF 6 Pro CMD 0004100 Modify Code 39 Pro CMD 0004130 Modify Codabar Pro CMD 0004150 Modify Code 93 Pro CMD 0004170 ...

Страница 131: ...D 0004020 Modify UCC EAN 128 Pro CMD 0004030 Modify Code 11 Pro CMD 0004280 Modify EAN UCC Composite Pro CMD 0004300 Modify GS1 Databar Pro CMD 0004310 Modify ISBN Pro CMD 0004240 Modify Industrial 25 Pro CMD 0004250 Modify Standard 25 Pro CMD 0004260 Modify Plessey Pro CMD 0004270 Modify MSI Plessey Pro CMD 0004290 ...

Страница 132: ...appear to the right of a barcode User Suffix Disable or Enable User Suffix User suffix is appended to the right of barcode message For example if user suffix is AB and the barcode message is 123 The Host receives 123AB Disable User Suffix Pro CMD 0306000 Enable User Suffix Pro CMD 0306010 Program User Suffix Read Program User Suffix Then program user suffix byte s To end the suffix read Save programming The...

Страница 133: ...t and the very end of a barcode transmission Disable Terminal Pro CMD 0309000 Enable Terminal Pro CMD 0309010 Program Terminal Read Program Terminal Then program terminal byte s To end the suffix read Save programming The terminal byte is programmed in its hex values See example below Note The maximum length for terminal is 2 bytes Program Terminal Pro CMD 0310000 Program Ox0D as Terminal Pro CMD 0...

Страница 134: ... s Message intercept only applies to raw barcode messages The sequence of a read to transmit without message intercept is Read a raw barcode Add prefix Append suffix Append terminal Transmit to Host The sequence of a read to transmit with message intercept is Read a raw barcode Intercept Message Add prefix Append suffix Append terminal transmit to Host A special programming pack can insert barcode mes...

Страница 135: ...f there are more than one options programmed for a barcode format the later one is used For example there are 3 options restored Code 128 option A QR Code option Code 128 option B The Code 128 option B is used when a Code 128 barcode is read Disable Interception Pro CMD 0315000 Enable Interception Pro CMD 0315010 Program Intercept Option Pro CMD 0316000 Erase Certain Barcode Interception Options P...

Страница 136: ...ommand format of 1D interception command regards a 3 digit decimal number as a unit The interception command has two parts which are barcode type part Symbol ID and data interception part A command could have several data interception parts A barcode type part Symbol ID uses a unit such as 005 a datainterception part uses three units including intercepting direction unit 000 Ascending or 001 Desce...

Страница 137: ...5 When programming 2D intercept option read digit codes as interception command The rules is as below The interception command has two parts which are barcode type part Symbol ID and data interception part A command could have several data interception parts A barcode type part Symbol ID uses a unit such as 005 a data interception part uses three units including intercepting direction unit 000 Asc...

Страница 138: ...t be sure to load the default Disable Pack if pack is not required Disable Pack Pro CMD 0314000 Normal Pack Normal pack format STX ATTR LEN AL_TYPE DATA LRC STX 0x02 ATTR 0x00 LEN Barcode message length is expressed by 2 bytes range 0x0000 0xFFFF which is between 0 and 65535 AL_TYPE 0x36 DATA Barcode message LRC Parity byte The algorithm computation sequence is LRC 0xFF STX ATTR LEN AL_TYPE DATA 1...

Страница 139: ...ub command and its terminator semicolon Save Programming 0000160 to terminate 3 Use Barcode Generator software to make the 2D batch barcode 4 For example to generate a batch barcode for Illumination Keep ON 0200030 Auto Mode 0302010 One Reading Timeout 2000 0313000 and Disable Fixed Length Selection 0405140 for Inter leaved 2 of 5 0200030 0302010 0313000 2000 0405140 0000160 Generate a batch code ...

Страница 140: ...g timeout setting same barcode reading delay setting sensitive value setting etc e g The command setting the one reading timeout as 3000ms 0313000 3000 The command setting the sensitive value as 10 0312040 10 Setting syntax 3 command equal mark hex e g 0x101a 0x2C03 3 This command can be used as setting the user defined prefix user defined suffix ending suffix CodeID increase or cancel the barcode leng...

Страница 141: ...uce a batch command means light Always On Auto Scan change delay time to 2 seconds Disable Fixed Length of I 2 of 5 Firstly find commands as follows 0200030 light Always On 0302010 Auto Mode 0313000 2000 change One Reading Timeout to 2 seconds 0405140 Disable Fixed Length of Interleaved 2 of 5 0000160 Save The batch setting code PDF417 is as follow ...

Страница 142: ...batch setting code Code Programming ON Pro CMD 0006010 Allow Read Batch Code Pro CMD 0001110 Batch Setting Code Code Programming OFF Pro CMD 0006000 Read Code Programming ON then read enable batch setting code and then read the batch setting code produced just now finally Read Code Programming Off ...

Страница 143: ...ppendix Digit Code It is must to be read save after read digit code 0 Pro CMD 0000000 1 Pro CMD 0000010 2 Pro CMD 0000020 3 Pro CMD 0000030 4 Pro CMD 0000040 5 Pro CMD 0000050 6 Pro CMD 0000060 7 Pro CMD 0000070 ...

Страница 144: ...Page 138 Appendix Digit Code 8 Pro CMD 0000080 9 Pro CMD 0000090 A Pro CMD 0000100 B Pro CMD 0000110 C Pro CMD 0000120 D Pro CMD 0000130 E Pro CMD 0000140 F Pro CMD 0000150 ...

Страница 145: ...a program code is received then 1 2 3 in order is received if then read Abort One Data of Current Setting the 3 will be deleted if read Abort One String of Current Setting the 123 will be deleted if read Abort Current Setting both the program code and 123 will be deleted the device will be on status of initiating program code Save Pro CMD 0000160 Abort One Data of Current Setting Pro CMD 0000170 A...

Страница 146: ... Programming Baud Rate 9600 RS232 Serial Port Check No Check RS232 Transmit Digits 8 Digits RS232 Stop Digit 1 Digit Fixed RS232 Hardware Auto Flow Control Off RS232 Unkown Character Beep Off USB HID KBW Emulate ALT keypad Off USB HID KBW Function Key Mapping Off USB HID KBW Keystroke Delay No Delay USB HID KBW Caps Lock Off USB HID KBW Convert Case Off USB HID KBW Emulate Numeric Keypad Off USB H...

Страница 147: ...AN 13 Off EAN 13 Enable On Send Check Digit On Enable 2 Digits Addenda Code Off Enable 5 Digits Addenda Code Off UPC E Enable On Send Check Digit On Enable 2 Digits Addenda Code Off Enable 5 Digits Addenda Code Off Expand to UPC A Off Send Default 0 Off UPC A Enable On Send Check Digit On Enable 2 Digits Addenda Code Off Enable 5 Digits Addenda Code Off Send Default 0 Off Interleaved 2 of 5 Enable...

Страница 148: ...No less than 4 Code 39 Enable On Check Off Send Start Stop Character On Support Full ASCII Off Max Message Length 48 Min Message Length 1 Codabar Enable On Check Off Send Start Stop Character On ABCD ABCD Upper Case Max Message Length 60 Min Message Length 2 Code 93 Enable Off Check On Send Check Digit Off Max Message Length 48 Min Message Length 1 No less than1 UCC EAN 128 Enable On GS1 Databar E...

Страница 149: ... Digits On Industrial 25 Enable Off Check Off Max Message Length 48 Min Message Length 6 No less than 4 Standard 25 Enable Off Check Off Max Message Length 48 Min Message Length 6 No less than 4 Plessey Enable Off Check and Transmit Check Digits On Max Message Length 48 Min Message Length 4 No less than 4 MSI Plessey Enable Off Check and Transmit Check Digits On Single MOD10 Check On Max Message L...

Страница 150: ...age Length 7089 Min Message Length 1 Aztec Enable Off Max Message Length 3832 Min Message Length 1 Reading Multi barcodes of an Image Off Data Matrix Enable On Max Message Length 3116 Min Message Length 1 Read Single DM Only On Rectangular Symbols On Read Forward Direction Barcode Only On Maxicode Enable Off Max Message Length 150 Min Message Length 1 Maxicode Enable Off Max Message Length 7827 Mi...

Страница 151: ...ix 2 of 5 Xm Code 39 Am 0 1 3 4 5 7 Codabar Fm 0 2 4 Code 93 G0 Code 11 Hm 0 1 3 ISBN X0 Industrial 25 S0 Standard 25 R0 Plessey P0 MSI Plessey Mm 0 1 GS1 Databar e0 EAN UCC Composite em 0 3 PDF417 Lm 0 2 QR Code Qm 0 6 Aztec zm 0 9 A C Data Matrix dm 0 6 Maxicode Um 0 3 Chinese Sensible Code Xm Reference ISO IEC 15424 2008 Information technology Automatic identification and data capture techniques...

Страница 152: ...13 d UPC E c UPC A c Interleaved 2 of 5 e ITF 6 e ITF 14 e Matrix 2 of 5 v Code 39 b Codabar a Code 93 i Code 11 H GS1 Databar R EAN UCC Composite y ISBN B Industrial 25 I Standard 25 f Plessey n MSI Plessey m PDF417 r QR Code s Aztec z Data Matrix u Maxicode x Chinese Sensible Code h ...

Страница 153: ...eaved 2 of 5 008 ITF 14 009 ITF 6 010 Matrix 2 of 5 011 Code 39 013 Codabar 015 Code 93 017 ISBN 024 Industrial25 025 Standard25 026 Plessey 027 Code11 028 MSI Plessey 029 EAN UCC Composite 030 GS1 Databar 031 PDF417 032 QR Code 033 Aztec 034 DataMatrix 035 Maxicode 036 Chinese Sensible Code 039 User Define Code 041 SPEC_OCR_B 064 ...

Страница 154: ... XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF Device Control 3 14 20 DC4 Device Control 4 15 21 NAK Negative Acknowledgemnt 16 22 SYN Synchronous Idle 17 23 ETB End of Trans Block 18 24 CAN Cancel 19 25 EM End of Medium 1a 26 SUB Subsitute 1b 27 ESC Escape 1c 28 FS File Separator 1d 29 GS Group Separator 1e 30 RS Request to Send 1f 31 US Unit Separator 20 32 SP Space 21 33 Exclam...

Страница 155: ...36 54 6 37 55 7 38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 Less Than 3d 61 Equal Sign 3e 62 Greater Than 3f 63 Question Mark 40 64 AT Symbol 41 65 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X ...

Страница 156: ...36 54 6 37 55 7 38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 Less Than 3d 61 Equal Sign 3e 62 Greater Than 3f 63 Question Mark 40 64 AT Symbol 41 65 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X ...

Страница 157: ...ID TECH 10721 Walker Street Cypress CA 90630 714 761 6368 www idtechproducts com 80108506 001 rev B ...

Отзывы: