Page 113
Symbols
Code Programming ON
Code Programming OFF
Tools
Maxicode
Min Message Length (default: 1)
【
Pro CMD
:
0505030
】
Max Message Length (default:150)
【
Pro CMD
:
0505040
】
Select Message Length
It is used to program the valid reading length of Maxicode. The engine will not send
barcode message to the Host, if the decoded data length does not match the valid
reading length.
Maxicode Message Length is de
fi
ned by "Min. Message Length" and "Max.
Message Length ".
2D bar code Message Length should not exceed 65535 bytes.
Max Message Length should not be less than Min Message Length.
To read a
fi
xed length Maxicode, Please program Max & Min Message Length to the same
value.
To set Min Message Length of Maxicode to 8 bytes and Max Message Length to 12
bytes, read these programming codes.
1.
“
Code Programming ON
”
2.
“
Select Min Message Length
”
3. Digit Code
“
8
”
, see Digit Code
4. Save Programming
”
, see Digit Code
5. Select Max Message Length
”
6. Digit Code
“
1
”
7. Digit Code
“
2
”
8.
“
Save Programming
”
9.
“