IDT P9025AC Скачать руководство пользователя страница 6

P9025AC FOD TUNING GUIDE

6

REVISION  08/26/15

AN-886  

Figure 3. P9025AC FOD2 Global Offset Shift vs. FOD2 Resistance to GND

Option #1: Disabling FOD

Disabling FOD can be done with a few simple steps: 

First, P9038 Tx needs to be configured with GPIO4 connected to LDO2p5V with a resistor so that the pin is always at 2.5V during 
startup. This will disable the P9038 from shutting down due to changes from expected input power levels that deviate from the 
reported power value from the Rx. 

Second, the FOD1 pin on the P9025AC Rx should be connected to GND. This will have the effect of selecting the 
pre-programmed Bank 10, which maxes out the reported power level. If using the P9025AC-R-EVK reference board, this can be 
accomplished by placing a zero-ohm resistor in R4. 

Third, the resistor from FOD2 to GND on the P9025AC Rx should be set to 20k

. This will add +300 mW of offset to the reported 

power value and make it so that FOD-invoked shutdowns cannot happen when using the P9038, and will be very unlikely when 
using the P9025AC with other WPC transmitters. If using the P9025AC-R-EVK reference board, this is resistor R5.

Содержание P9025AC

Страница 1: ...on the pre programmed FOD curve For WPC compliant systems the loss allowed due to foreign objects is 350 mW not including known losses due to the Tx and Rx systems For systems where WPC compliance is...

Страница 2: ...sfer and decode communication packets Respectively the Rx device measures the power that it is receiving i e delivering to the load and reports that value to the Tx module Since the Rx circuit and sys...

Страница 3: ...for exact values The Rx Reported Received Power vs Load Current graph is an indication of the power lost due to the electrical operations required for the Tx and Rx to function as the load current cha...

Страница 4: ...WER_FOD reported level This offset is applied by connecting an external resistor from pin FOD2 to GND and directly affects the received power level that is reported to the transmitter across the load...

Страница 5: ...At 0 9V the offset is 0 mW At 0 V the offset is 300mW and at 1 8V the offset is 300mW The Rx reported received power shift can be calculated using the following equation where VFOD2 is found using equ...

Страница 6: ...power value from the Rx Second the FOD1 pin on the P9025AC Rx should be connected to GND This will have the effect of selecting the pre programmed Bank 10 which maxes out the reported power level If...

Страница 7: ...left hand input table labeled First data set 7 Move the Rx coil exactly 5mm away from the Optimal Alignment Location in any direction that is 90 Clock wise or counter clockwise from the direction chos...

Страница 8: ...the recommended bank by highlighting the suggested FOD1 and FOD2 resistances to use under the Bank row The listed values in the FOD1 section are the largest reported power error contained within the...

Страница 9: ...REVISION 08 26 15 9 P9025AC FOD TUNING GUIDE AN 886 be filled in...

Страница 10: ...100 MDT BST Reference Testers should be used in conjunction with calibrated lab equipment These laboratories offer excellent Qi compliance FOD determination services and they are recommended Due to th...

Страница 11: ...license under intellectual property rights of IDT or any third parties IDT s products are not intended for use in applications involving extreme environmental conditions or in life support systems or...

Отзывы: