You will need

As you unpack and begin to set up your new electrisave ™ you will need the following equipment:

• User manual – for instructions on how to set up and use the product.

• A hammer and 2x 2mm head nails – to fix the mounting bracket/unit to the wall. Alternatively you may screw the bracket to

the wall or simply place the transmitter carefully inside the meterbox.

• A small Philip’s-head screw driver - to open the battery compartment of the Transmitter.

Unpacking the product

When you unpack your electrisave™, make sure to keep all the packing materials in a safe place, in case you need to later
transport or return it for servicing.

In the box, you will find:

Batteries

The Portable Main Unit Receiver and the Remote Transmitter both use 3 x UM-3/AA 1.5V alkaline batteries. No other power
source is necessary to run the units. 

Loading the batteries:

Main unit – Receiver

NOTE 

Replace the batteries whenever the weak battery mark ‘main’ or ‘remote’ () shows, the display is dim, or the display

does not illuminate when the power is on. Replace all the batteries at the same time – it is 

unwise

to mix old and new

batteries.

Contact your local waste disposal authority for instructions on how to dispose of used batteries. Used batteries can be
harmful to the environment, and should not be thrown out with household rubbish.

AC Adaptor

The main unit receiver can operate with a 6.0V AC/DC adaptor, which can be purchased separately.

9

GETTING STARTED

Main Unit
Receiver

Diagram

Instructions

Diagram

Instructions

Remote Transmitter
(with wall Bracket)

Current Sensor

Batteries x 6
AA alkaline

User Manual &
Quick Install Guide

Install the batteries by matching the
correct polarity.  Always use the
correct battery type (

3 x UM-3/AA

1.5V alkaline batteries

).

Warning:

Reversing the polarity

may damage the product.

Remove the cover with a
screwdriver. Then follow the same
instructions as the main unit. 

Once done, replace the cover and
screw back the cover onto the unit.

Содержание CMR113A

Страница 1: ......

Страница 2: ......

Страница 3: ...ecifications 16 Declaration of Conformity 17 Default Values 18 Warranty 18 Proof of Purchase 19 is a product of WIRELESS MONITORS AUSTRALIA PTY LTD ACN 098 657 231 Manufactured under license in China...

Страница 4: ...es operating that should have been turned off when you go to bed or leave the home unattended simply check the receiver display If it is higher that usual investigate the cause and turn off any unnece...

Страница 5: ...C Phase Connecter Cable Outlets D Reset Hole E Battery Compartment weather proof Requires screwdriver to open Front Current Sensor Back A Hinge B Clip C Sensor top part D Hole for electricity phase wi...

Страница 6: ...ons information Amperes The amount of current passing into your home Voltage The voltage electrical pressure setting for your household power line Kilograms per hour The amount of greenhouse gas emiss...

Страница 7: ...r shock When disposing of this product do so in accordance with your local waste disposal regulations Safety precautions Please observe the following safety precautions when setting up and using this...

Страница 8: ...1 Step 11 For trouble shooting Guide refer to page 16 Alternative sensor installation The sensors are suitable for use with wire diameters of up to 11mm They must not be forced over cables greater tha...

Страница 9: ...phase or three phase current In single phase supplies the current flows to and from your household appliances using a neutral and power line The neutral line has a voltage close to 0 while the power...

Страница 10: ...Replace the batteries whenever the weak battery mark main or remote shows the display is dim or the display does not illuminate when the power is on Replace all the batteries at the same time it is u...

Страница 11: ...tions below Attaching the Current Sensor WARNING If in doubt about installing this product yourself please consult a qualified electrician To attach the Current Sensor to the household power line see...

Страница 12: ...electrisave Main Unit Receiver immediately starts receiving information The LCD screen displays electricity consumption and greenhouse gas readings based on default factory settings see SPECIFICATION...

Страница 13: ...ing speed of the Main Unit Receiver from every 6 seconds MAX to every minute To change the setting follow the instructions below 12 Diagram Instructions 1 Press mode and alarm simultaneously 2 The cur...

Страница 14: ...power consumption in amps Household power consumption can be displayed in terms of amps instead of kilowatts see HOW THE PRODUCT WORKS To display the amount of electrical current passing into your ho...

Страница 15: ...he Main Unit Receiver and the Remote Transmitter If you are resetting to re establish a connection between the units the main receiver unit must be reset first 14 Diagram Instructions 1 Press alarm on...

Страница 16: ...for three seconds Humidity is shown as a and temperature in degrees Celsius o C An additional feature of the humidity display is a series of icons to indicate if the environment is comfortable dry or...

Страница 17: ...ncy and cent Hi alarm 2 00 hour on Receiving cycle MAX 6 second Display Mode Cost rate display 16 TROUBLESHOOTING GUIDE SPECIFICATIONS Problem Symptom Check this Remedy No power or no reading reading...

Страница 18: ...compliance with European CE Certification RTTE CE approved Europe FCC UL USA IC Canada and applicable Australian and New Zealand Communications and Electricity Authorities Regulations N12357 We Name...

Страница 19: ...ns 2 Warranty will only be given where proof of purchase date is provided Eg original invoice or copy 3 This instrument must not be modified in any way 4 Batteries are specifically excluded from this...

Страница 20: ...ond this timeframe 3 To ensure returns for defective unit s are processed quickly customers are required to send with returned unit s proof of purchase details as shown on the following page WARRANTY...

Отзывы: