Section: 1
IDS X64 Remote Receiver 700-408-02A Issued August 2010
6
D+ WHITE
D- GREEN
(These colours are only a guideline).
5.
Equipment to be remotely switched should be connected to the RELAY1 and RELAY2 terminals
of the Remote Receiver. The relay current ratings (see section 1.5) must not be exceeded. If the
Remote Receiver relays are configured as "secure", the effective terminals for "NC" (Normally
Closed) and "NO" (Normally Open) will be swapped.
6.
Keep the Remote Receiver cover off during configuration, so that the DIPswitches are accessible
and the LEDs are visible.
7.
When configuration is complete and the Remote Receiver is working, replace the cover.
1.5
Electrical Specifications
Supply Voltage:
10 to 15 V
DC
Current Consumption:
30mA
Relay Rating Contacts:
1 A @ 30 V
DC
Minimum Receiver Sensitivity:
≤ -100 dBm
Receiver Frequency:
433.92 MHz
2.
Panel Mode
These settings only apply to receivers being used
with
the IDS X64 Alarm Panel. All remotes follow these
settings; they cannot be different from one remote to the next.
2.1
Button Assignment
The functions that can be assigned to a button are: arm/disarm, stay, relay 1, and relay 2. Each button
can be assigned multiple functions, or no function. It cannot be assigned both arm/disarm and stay.
Different buttons can be assigned the same function.
The factory defaults for the buttons are as follows:
Button 1: Arm/Disarm
Button 2: no function
Содержание X64
Страница 1: ......
Страница 2: ...IDS X64 Remote Receiver 700 408 02A Issued August 2010 2...
Страница 22: ...IDS X64 Remote Receiver 700 408 02A Issued August 2010 22...
Страница 23: ...IDS X64 Remote Receiver 700 408 02A Issued August 2010 23...
Страница 24: ...IDS X64 Remote Receiver 700 408 02A Issued August 2010 24...