Dip Switch
Dip Switch 1 - Battery Saving Timer
Position
Function
ON
Even if there are continuous alarms, the alarm is only generated once
in a 120 second time. To lengthen battery life.
OFF
The alarm is generated whenever there is an alarm condition.
Dip Switch 2 – Intermittent Output Function
Position
Function
ON
Sets the Alarm output to trigger intermittently (every 1 minute) if a
continuous alarm condition occurs.
OFF
The Alarm output triggers only once on an alarm condition.
Dip Switch 3 – Alarm Output
Position
Function
ON
Sets the output type to Normally Open (N.O.)
OFF
Sets the output type to Normally Closed (N.C.)
Battery Holder
Holds 2 x LSH 20
batteries
Tamper Switch