November 2017 15
Operation: IDS NXT
·
Set the switching time for the flash output in microseconds under "Duration". The flash output is switched for
the set time. The value 0 means that the flash is deactivated.
·
Under "Logic", you can set whether the signal of the flash output is set to high or low active.
6.2 General settings
In the "General settings" area, you can assign a descriptive name for the device, enter the installation location
for identification or change the avatar image.
General device settings
For the device name and the installation location, a name with a maximum of 32 characters can be assigned.
The following specifications apply to the avatar image:
·
Image size: 256 x 256 pixels
·
Image format: JPEG, GIF, BMP or PNG
Date/Time
Under "Date/Time", you can set the time zone, date and time. Alternatively, you can specify an NTP time
server for time synchronization.
Audible feedback
In delivery state, both the audible and visual feedback signals are deactivated.
The IDS NXT can be configured to signal an audible feedback for different actions. The following feedbacks are
possible:
·
Device errors
·
Image processing errors ("Vision failed")
·
Image processing OK ("Vision OK")