4 Standards and directives

(only valid for devices with housing)

IDS Imaging Development Systems GmbH hereby confirms that this product has been developed, designed
and manufactured in compliance with the following European directives

·

2014/30/EU: EMC - Electromagnetic compatibility

·

2011/65/EU: RoHS - Restriction of the use of certain hazardous substances in electrical and electronic
equipment

·

Regulation (EC) No. 1907/2006 concerning the Registration, Evaluation, Authorization and Restriction of
Chemicals (REACH)

·

The CE declaration of conformity is available on the 

IDS website

.

If the product is modified or changed all approval becomes invalid. In this case the customer is responsible for
ensuring product conformity.

Product type

IDS NXT rome

Information for CE

EMC specifications

EN 61000-6-2
EN 55035
EN 61000-6-4*
EN 55032 (Class A)

Information for USA

This equipment has been tested and found to comply
with part 15 of the FCC Rules

Class A

Information for Canada
Renseignements pour le Canada

CAN ICES-3 (A)/NMB-3(A)

Information for UL

UL 62368-1
CAN/CSA C22.2 No. 62368-1-14

Further information

RCM

* Cameras are intended exclusively for use in industrial environments.

For customers in the USA

For a class A digital device:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference
at his own expense.

Name of Responsible Party

IDS Imaging Development Systems, Inc.
92 Montvale Ave., Ste 2800
Stoneham, MA 02180
U.S.A.
T: +1 781 787 0048

Содержание NXT rome

Страница 1: ...IDS NXT IDS Imaging Development Systems GmbH Dimbacher Str 6 8 D 74182 Obersulm Germany T 49 7134 96196 0 E info ids imaging com W http www ids nxt com Setup IDS NXT rome...

Страница 2: ...nment I O connector 11 7 Status LED 13 8 Setup in network 14 8 1 Installing IDS NXT cockpit 14 8 2 Getting an IP address 14 8 3 Establishing a connection 14 8 4 Logging on to the device 15 8 5 Network...

Страница 3: ...nor limited by the information contained in this manual Should you require further information on this product or encounter specific problems that are not discussed in sufficient detail in the manual...

Страница 4: ...s symbol indicates hints with useful information for better understanding and using features and functions This symbol indicates important warnings for product safety to prevent damage This symbol ind...

Страница 5: ...board while it is powered Always hold the board by the edges to avoid the risk of electrostatic discharge damage For optimum ESD behavior a clearance of 4 mm from non shielded housings must be mainta...

Страница 6: ...de s curit LPS source puissance limit e ou ES1 PS2 Pour garantir la s curit lectrique nous recommandons l utilisation d un c ble de connexion blind ou la mise la terre du bo tier de la cam ra afin qu...

Страница 7: ...nd found to comply with part 15 of the FCC Rules Class A Information for Canada Renseignements pour le Canada CAN ICES 3 A NMB 3 A Information for UL UL 62368 1 CAN CSA C22 2 No 62368 1 14 Further inf...

Страница 8: ...al specifications Mounting holes bottom top side front 4 0 0 0 3 0 0 0 Thread diameter M3 M5 Status LED Status LED Interface connector M12 connector screwable Power supply Input I O connector M12 12 2...

Страница 9: ...re tested as specified in EN 60068 2 6 and EN 60068 2 27 Test parameter EN 60068 2 6 Environmental testing Tests Vibration Vibration mode Sinus Lower frequency 30 Hz Upper frequency 500 Hz Acceleratio...

Страница 10: ...o ensure optimum performance of the network connection you need to install the latest drivers for your network card GigE network adapters for PCI slots are limited in its transfer rate to approximatel...

Страница 11: ...Attend 216A 12MSR Pin Signal Description Fig 3 I O connector camera rear view 1 VBUS Power supply 12 24 V DC 20 2 VBUS GND Reference level ground for power supply and RS 232 3 Opto IN 0 Trigger input...

Страница 12: ...ove are available at the input of the camera Avis pour le Canada IDS Imaging Development Systems GmbH recommande d adapter l alimentation lectrique aux besoins de la cam ra afin de limiter la surchauf...

Страница 13: ...LED 1 camera status two color LED 2 Network status two color LED 1 Camera is off no power Camera is booting Camera is ready Camera is open Camera is ready no valid IP address No firmware loaded Servi...

Страница 14: ...ain the IP address via DHCP DHCP The camera is assigned a valid IP address by the DHCP server Afterwards you can log on to the camera with IDS NXT cockpit and set the network parameters The network ca...

Страница 15: ...e allows full access to the IDS NXT camera s configuration From firmware updates to installing and setting IDS NXT vision apps everything is possible Service This user profile can be used to perform s...

Страница 16: ...ich displays various device information To set the network parameters select Configuration Network The Obtain IP address automatically DHCP option is activated by default It is recommended to keep thi...

Страница 17: ..._deviceupdate tool can be found in the installation directory of the IDS NXT cockpit e g under C Program Files IDS ids_nxt_cockpit_2_0 visiontools The command line tool allows you to select the camera...

Страница 18: ...XT rome 2 Make sure that camera and host are in the same subnet 3 The following steps are identical to the description under IP address with DHCP After the firmware update the camera will automaticall...

Страница 19: ...ssword be reset If you have changed the camera s administrator password and you do not remember it you must reset the camera to the factory settings in order to assign a new password To do this boot t...

Страница 20: ...e g under C Program Files IDS ids_nxt_cockpit_2_0 visiontools Fig 7 Boot service firmware 1 Open the ids_devicecommand tool at the command prompt 2 You can first display all available cameras to ident...

Страница 21: ...ust be uploaded to the camera again 10 3 Booting the camera in runtime firmware Use the ids_devicecommand tool to boot the camera in runtime firmware The ids_devicecommand tool can be found in the ins...

Страница 22: ...5 F Factory setting reset 20 Firmware runtime 19 21 service 19 20 update 17 G GigE connector 11 I I O connector 11 IDS NXT cockpit 19 install 14 network setting 16 start 14 IP address 14 19 DHCP 16 1...

Отзывы: