2023-10-25
12
IDS NXT malibu: Technical Manual
Device temperature during storage
-20 °C … 60 °C
-4 °F … 140 °F
Humidity
20 % ... 80 %, relative, non-condensing
Non-condensing means that the relative air humidity must be below 100 %. Otherwise, moisture will form on
the camera surface. If, for example, air has a relative humidity of 40 % at 35 °C (95 °F), the relative humidity
will increase to over 100 % if the air cools down to 19.5 °C (67 °F); condensation begins to form.
CAUTION!
As the camera housing may get hot depending on the operating conditions there
may be risk of burns. Provide sufficient heat dissipation so that the housing temperature does
not exceed 55 °C (131 °F).
Notes on ambient conditions
·
Avoid high air humidity levels and rapid temperature changes when using IDS cameras.
·
Temperatures below +4 °C (39 °F) combined with excessive relative air humidity levels can cause icing.
·
Note that with increasing device temperatures, the image quality may decrease due to thermal noise, even if
the camera is operated below the maximum specified temperature.
Provide sufficient heat dissipation to keep temperatures within the specified ranges. The exact temperature
conditions depend on the mounting situation. In general, the following recommendations apply:
·
Use a thermally-conductive surface, like a metal plate or a heat sink, for a passive heat dissipation.
·
If necessary, provide an active cooling for example by means of a fan.
4.4 Electrical specifications
Pin assignment GigE connector (RJ45)
4.4.1 Pin assignment GigE connector (RJ45)
The RJ45 socket of the IDS NXT malibu complies with the IEC 60603-7 standard.