background image

IDS

 

Keypad

 

Bus

 

Remote

 

Receiver

 

IDS

 

Keypad

 

Bus

 

Remote

 

Receiver

 

IDS

 

Keypad

 

Bus

 

Remote

 

Receiver 

3

 

Sec

 

Hold

 

for

 

Panic

 

Button

 

All 

Signal

 

Jamming

 

Detect

 

Period

 

30s 

Device

 

Not

 

Reporting

 

1hr

 

max 

 

 

Deleting

 

ALL

 

the

 

User

 

Remotes

 

:

 

 

1.

    

Remove

 

power

 

from

 

the

 

unit

 

by

 

removing

 

jumper

J1

 

and

 

switch

 

all

 

Dip

 

switches

 

OFF. 

2.

    

Switch

 

Dip

 

switches

 

2,

 

5,

 

6,

 

7

 

and

 

8

 

ON 

3.

    

Restore

 

Power

 

to

 

the

 

Unit

 

by

 

replacing

 

J1 

4.

    

Switch

 

Dip

 

Switch

 

8

 

OFF 

5.

    

Wait

 

for

 

the

 

LED’s

 

to

 

start

 

alternating 

6.

    

Switch

 

ALL

 

Dip

 

switches

 

OFF. 

7.

    

When

  

the

  

LED’s

  

stop

  

flashing

  

the

  

unit

  

is

  

in

  

the

normal

 

operating

 

mode 

 

Deleting

 

all

 

Supervised

 

RF

 

Devices

 

(e.g.

 

RF

 

Passive

 

IR's)

 

:

 

8.

    

When

  

the

  

LED’s

  

stop

  

flashing

  

the

  

unit

  

is

  

in

  

the

normal

 

operating

 

mode 

 

Assigning

 

an

 

Arm

 

/

 

Disarm

 

Button

 

on

 

a

 

Remote

 

:

 

 

N.B.

 

This

 

Function

 

will

 

affect

 

ALL

 

remotes.

 

1.

    

Remove

 

power

 

from

 

the

 

unit

 

by

 

removing

 

jumper 

J1

 

and

 

switch

 

all

 

Dip

 

switches

 

OFF. 

2.

    

Switch

 

Dip

 

switches

 

3

 

and

 

8

 

ON 

3.

    

Restore

 

Power

 

to

 

the

 

Unit

 

by

 

replacing

 

J1 

4.

    

Press

  

the

  

button

  

on

  

a

  

known

  

remote

  

that

  

will

become

 

the

 

Arm

 

/

 

Disarm

 

button. 

5.

    

Switch

 

Dip

 

switch

 

8

 

OFF. 

6.

    

Wait

 

for

 

the

 

LED’s

 

to

 

start

 

flashing

 

alternately. 

7.

    

Switch

 

ALL

 

Dip

 

switches

 

OFF. 

8.

    

When

  

the

  

LED’s

  

stop

  

flashing

  

the

  

unit

  

is

  

in

  

the

normal

 

operating

 

mode. 

 

Assigning

 

a

 

Stay

 

Arm

 

Button

 

on

 

a

 

Remote

 

:

 

Remote

 

Arm

 

or

 

Disarm

 

3

 

Minute

 

Retrigger

 

Protecting

 

:

 

 

1.

    

Switch

  

Dip

  

switch

  

2

  

ON

  

to

  

enable

  

retrigger

 

protecting. 

 

To

 

indicate

 

the

 

Ambient

 

Noise

 

Level

 

:

 

 

 

N.B.

  

This

  

function

  

must

  

be

  

disabled

  

during

  

normal

operation

 

This

 

function

 

allows

 

the

 

testing

 

of

 

ambient

 

noise

 

in

 

the

environment

   

surrounding

   

the

   

receiver

   

during

installation. 
1.

    

Switch

  

Dip

  

switch

  

4

  

ON

  

to

  

enable

  

noise

  

level

 

testing. 

2.

    

ONLY

 

install

 

the

 

receiver

 

in

 

an

 

environment

 

with 

Normal

 

or

 

Better

 

Noise

 

Levels. 

 

During

 

Noise

 

Testing

 

the

 

LED’s

 

indicate

 

the

 

following: 

1.

    

Remove

 

power

 

from

 

the

 

unit

 

by

 

removing

 

jumper

J1

 

and

 

switch

 

all

 

Dip

 

switches

 

OFF. 

2.

    

Switch

 

Dip

 

switches

 

3,

 

5,

 

6,

 

7

 

and

 

8

 

ON 

N.B.

 

This

 

Function

 

will

 

affect

 

ALL

 

remotes.

 

1.

    

Remove

 

power

 

from

 

the

 

unit

 

by

 

removing

 

jumper 

J1

 

and

 

switch

 

all

 

Dip

 

switches

 

OFF. 

OFF 

RED

 

LED

 

OFF 

GREEN

 

LED

 

NOISE

 

LEVEL

 

VERY

 

LOW 

3.

    

Restore

 

Power

 

to

 

the

 

Unit

 

by

 

replacing

 

J1 

4.

    

Switch

 

Dip

 

Switch

 

8

 

OFF 

5.

    

Wait

 

for

 

the

 

LED’s

 

to

 

start

 

flashing

 

alternately. 

6.

    

Switch

 

ALL

 

Dip

 

switches

 

OFF. 

7.

    

When

  

the

  

LED’s

  

stop

  

flashing

  

the

  

unit

  

is

  

in

  

the

normal

 

operating

 

mode 

2.

    

Switch

 

Dip

 

switches

 

2

 

and

 

8

 

ON 

3.

    

Restore

 

Power

 

to

 

the

 

Unit

 

by

 

replacing

 

J1 

4.

    

Press

  

the

  

button

  

on

  

a

  

known

  

remote

  

that

  

will

become

 

the

 

Stay

 

Arm

 

button. 

5.

    

Switch

 

Dip

 

switch

 

8

 

OFF. 

6.

    

Wait

 

for

 

the

 

LED’s

 

to

 

start

 

flashing

 

alternately. 

7.

    

Switch

 

ALL

 

Dip

 

switches

 

OFF. 

OFF 

OFF 

SLOW 

FAST 

ON 

SLOW 

FAST 

ON 

ON 

ON 

LOW 

NORMAL 

HIGH 

VERY

 

HIGH 

POSSIBLE

 

JAMMING 

Assigning

 

a

 

Dedicated

 

Panic

 

Button

 

to

 

a

 

Remote

 

:

 

 

N.B.

 

This

 

Function

 

will

 

affect

 

ALL

 

remotes.

 

1.

    

Remove

 

power

 

from

 

the

 

unit

 

by

 

removing

 

jumper

J1

 

and

 

switch

 

all

 

Dip

 

switches

 

OFF. 

2.

    

Switch

 

Dip

 

switches

 

4

 

and

 

8

 

ON 

3.

    

Restore

 

Power

 

to

 

the

 

Unit

 

by

 

replacing

 

J1 

7.

8.

    

When

  

the

  

LED’s

  

stop

  

flashing

  

the

  

unit

  

is

  

in

  

the

normal

 

operating

 

mode. 

 

 

Programming

 

the

 

Unit

 

in

 

Stand

 

-

 

Alone

 

Mode.

 

(Normal

 

Settings)

 

Learn

 

New

 

Panic

 

Remotes

 

:

 

 

1.

    

Switch

 

Dip

 

Switch

 

6

 

ON 

2.

    

Press

 

any

 

button

 

on

 

the

 

remotes

 

to

 

be

 

learned. 

3.

    

Switch

 

Dip

 

switch

 

6

 

OFF

 

to

 

exit

 

the

 

learn

 

mode.

 

 

Disable

 

the

 

3

 

second

 

Hold

 

for

 

Panic

 

Feature

 

:

 

4.

    

Press

  

the

  

button

  

on

  

a

  

known

  

remote

  

that

  

will

become

 

an

 

instant

 

panic

 

button. 

5.

    

Switch

 

Dip

 

switch

 

8

 

OFF. 

6.

    

Wait

 

for

 

the

 

LED’s

 

to

 

start

 

flashing

 

alternately. 

7.

    

Switch

 

ALL

 

Dip

 

switches

 

OFF. 

These

  

settings

  

may

  

be

  

adjusted

  

during

  

normal

 

operation

  

and

  

it

  

is

  

not

  

necessary

  

to

  

power

  

the

  

unit

 

down

 

for

 

the

 

settings

 

to

 

take

 

effect.

 

1.

    

To

 

disable

 

the

 

3

 

second

 

hold

 

for

 

panic

 

feature

 

on

ALL

 

remotes

 

switch

 

Dip

 

switch

 

7

 

ON. 

IDS 

IDS

 

700-284-4

 

B

 

August

 

2007

IDS

IDS 

4

 

5

 

6

 

Отзывы: