General description
Installation instructions TERRA AL Twin
30
1
2
3
4
5
6
Data cable 2x2x0.5 mm²
Control current 3G1.5 mm²
Primary current
AL 17 Twin 3x16 mm²
Primary current heat pump (1x230V/50HZ)
Control current (1x230V/50HZ)
Sensor and control lines on-site
Network cable
A network socket is already provided on the undersurface of the cabinet. For plug and play usage
of myIDM (heat-pump control via internet). The network cable have to be plugged in there.
6.
6.
6 Exterior installation
General description
General description
El
ec
trical co
nn
ec
tio
n
6. Electrical connection
6.1. Power supply
The electrical connection has to be registered with the
competent energy supply company.
The series-connected fuse for the primary circuit is
shown in the technical data, ensure that a fuse with
characteristics "C" or "K" is used.
The primary current for a possible electric heating im-
merser have to be set on site. The heating immerser
can be controlled by the Navigator control.
The TERRA AL Twin is equipped with two starting
current limiter.
The heat pump is operated via the navigator regula-
tion.
Depending on the system design, appropriate sen-
sors are required. See the connection diagrams.
To ensure a proper functioning of the heat pump, the
voltage in the network must lie within certain tolerance
limits, between 210 V and 250 V (if necessary, contact
your local energy supply company).
For data transmission, a shielded cable must be used. All electrical details can be derived from
the appropriate circuit diagram.