background image

OPF-TH2000/OPF-RH2000 User

’s Guide 

 

For installation 

For rack mount devices:   

Instruction

 

Mount the product to the rack meeting EIA standards, and maintain spaces above and 

below for air cooling. For your safety, attach an L-shape bracket in addition to the mount 

bracket kit for the front panel in order to balance the weight. 

For devices with rubber feet:   

 

Instruction

 

Never insert only the screws into the holes after removing the rubber feet. It may lead to 

damage when the screws contact electrical circuit or parts inside of the product.   

To put the rubber feet back on, use only provided rubber feet and screws. 

Altitude:   

 

Instruction

 

Do not place the product at elevations of 2,000 meters (6562 feet) or higher above sea 

level. Failure to do so may shorten the life of the internal parts and result in malfunctions. 

 

 

 

 

 

 

 

 

Prohibition 

Do not place the product in any place where it will be subjected to high 

temperatures.

 

If the product is subjected to direct sunlight or high temperatures, it may cause fire.

 

Do not place the product in humid, oil smoke, or dusty place. 

If the product is placed near humidifiers or dusty area, it may cause fire or electric shock.

 

Do not block the vent holes. 

If ventilation slots are blocked, it may cause fire or failure due to internal heat.

 

Do not put heavy items on the product. 

It may fall/turn over and lead to injury.

 

Do not exceed ratings of outlet and wiring devices. 

If several plugs are put in an outlet, it may cause fire and electric shock. 

 

Use only the provided AC adapter and power cable. 

If non-compliant adapter or power cables is used, it may cause fire or electrical shock. Use the provided AC 

power connection cable. If you want to use your product in other countries that use different AC power cables, 

contact IDK.

 

 

 

No wet hands

 

Do not plug or unplug with wet hands. 

It may cause electrical shock.

 

 

 

 

Instruction

 

Use and store the product within the specified temperature/humidity range. 

If the product is used outside the range continuously, it may cause fire or electric shock.

 

Turn off devices when they are connected to another device. 

It may cause fire or electric shock.

 

 

 

 

Unplug

 

Unplug the power plug if you do not use the product for a long period. 

In case of defect, it may cause fire.

 

Unplug the power plug before cleaning. 

It may cause electric shock.

 

Caution

 

 

 

 

Содержание OPF-TH2000

Страница 1: ...CAL TX SIGNAL RX POWER LAN STATUS DIP SW OPTICALTx for HDMI OPF TH2000 DC 5V 3A FG INPUT HDMI RS 232C Tx CLASS1 LASERPRODUCT 1 OPTICAL TX SIGNAL RX POWER LAN STATUS DIP SW Thank you for choosing our p...

Страница 2: ...e and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing LLC in the United States and other countries All other company and product names mentioned in this manual are either regis...

Страница 3: ...o frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is l...

Страница 4: ...l injury if the warning is ignored or the equipment is handled incorrectly Indicates the presence of a hazard that may cause minor personal injury or property damage if the caution is ignored or the e...

Страница 5: ...damage Set the power plug in a convenient place to unplug easily You can easily unplug in case of any extraordinary failure or abnormal situation and it also helps for unplugging when you do not use...

Страница 6: ...dusty place If the product is placed near humidifiers or dusty area it may cause fire or electric shock Do not block the vent holes If ventilation slots are blocked it may cause fire or failure due t...

Страница 7: ...ns 15 5 2 1 Installation 15 5 2 2 Cabling 15 5 2 3 Fiber optic cable 16 5 2 4 SFP module 16 5 2 5 Cascade connection 17 5 3 Settings 17 5 3 1 Setting DIP switch 17 5 3 2 Setting input equalizer only t...

Страница 8: ...main unit x 1 AC adapter with screw type lock 1 2 m 3 94 feet x 1 Cable clamp x 1 This User s Guide is common to both the transmitter and receiver You can download the latest version from IDK s websi...

Страница 9: ...transmitted without quality deterioration since they are not compressed or processed The OPF supports RS 232C bidirectional communication and LAN transmission For multi mode fiber Transmitter OPF TH2...

Страница 10: ...k of the AC adapter has a locking mechanism Projector Blu ray disk player Laptop HDMI OPF TH2000 Transmitter OPF RH2000 Receiver LAN RS 232C LAN RS 232C HDMI HDCP output HDCP output Fiber optic cable...

Страница 11: ...d to the receiver FG Frame ground An M3 screw is used Optical input connector for extension Input connector of digital optical signals for extension Connected to the optical output connector of receiv...

Страница 12: ...al input connector for extension Input connector of digital optical signals for extension Connected to the optical output connector of the transmitter using a fiber optic cable Optical output connecto...

Страница 13: ...ternal device has a DVI connector use a proper cable Followings are recommended cables from IDK Model number Length HDSS 005 0 5 m 1 64 ft HDSS 01 1 m 3 28 ft HDSS 02 2 m 6 56 ft HDSS 03 3 m 9 84 ft H...

Страница 14: ...r S 13085 2 DLC DLC S LXX S 13085 2 LC LC S LXX S 13086 2 DLC DLC LXX S 13085 2 DLC DLC U LXX S 13085 2 LC LC U LXX S 13086 2 LC LC LXX XX the length e g L10 10 m 32 8 ft LAN cable 1G bps Ethernet sig...

Страница 15: ...OPF H2000 in closed space If you have to install the product to an EIA rack mount in closed space add a ventilation to keep the ambient temperature of 40 degrees C 104 degrees F or less Exception Inst...

Страница 16: ...ou do not use the cable in order to prevent scratches and dirt Before connecting a fiber optic cable to the OPF make sure there is no scratch or dirt on the ends of the connector otherwise the OPF may...

Страница 17: ...Receiver Pre emphasis and swing of TMDS signals transmission response time of Hot Plug Detect and clock speed of Display Data Channel signals Default OFF SW1 to SW4 DIP switch For transmitter DIP SW...

Страница 18: ...s not transmitted 4 Sets the clock speed of the Display Data Channel 15 pin HDMI connector signals OFF Signals are output at 100 KHz from the receiver ON Signals are output at 75KHz from the receiver...

Страница 19: ...ce such as PCs Note The OPF TH2000 must be paired with OPF RH2000 The OPF H2000 cannot be connected to an I O slot board of the FDX series or other models of the OPF series Projector Blu ray player La...

Страница 20: ...TMDS data 2 10 TMDS clock 2 TMDS data 2 shield 11 TMDS clock shield 3 TMDS data 2 12 TMDS clock 4 TMDS data 1 13 CEC 5 TMDS data 1 shield 14 spare N C 6 TMDS data 1 15 SCL 7 TMDS data 0 16 SDA 8 TMDS...

Страница 21: ...ceive data 2 TRX Bi directional pair TX Transmit data TRX Bi directional pair RX Receive data 3 TRX Bi directional pair RX Receive data TRX Bi directional pair TX Transmit data 4 TRX Bi directional pa...

Страница 22: ...RD TD N C N C N C N C GND RTS CTS Pin No 1 3 2 4 6 5 7 9 8 Signal RD TD N C N C N C N C GND RTS CTS Signal RX data TX data Ground TX request RX request OPF H2000 IDK s product No connection No connect...

Страница 23: ...e HDMI Type A 2 Others Color depth 24bit 30 bit 36 bit Deep Color 4 Formats VGA SVGA XGA WXGA 1280x768 WXGA 1280x800 Quad VGA SXGA WXGA 1360x768 WXGA 1366x768 SXGA WXGA WXGA UXGA WSXGA WUXGA QWXGA 4K...

Страница 24: ...n distance ability due to an increase in return loss 6 The max extension distance above was measured under the following conditions a fiber polished by the recommended method was used no connection wa...

Страница 25: ...tly Are there no loose connections Are cables that are appropriate to this device being used Are signal specifications of connected devices matched to each other Are settings of the sink device correc...

Страница 26: ...ridge Road Suite 1 C Brookfield CT 06804 TEL 1 203 204 2445 Email info idkav com URL http www idkav com Europe IDK Europe GmbH Lise Meitner Str 6 D 40878 Ratingen Product information Support Arvanics...

Отзывы: