82
7.13.3 Command link
Menu Top
→
PRESET COMMAND
→
COMMAND LINK
Setting for [Table 7.18] Control command execution condition
Setting value OFF [Default], COMMAND 1 to COMMAND 32
The MSD has 37 command execution conditions as shown below. If these execution conditions are met,
control commands which are associated beforehand will be executed. One execution condition can be
associated to up to 10 commands. If several commands are associated, commands are executed in order of
registration. If the same command is associated several times, it is repeatedly executed.
The setting of this menu is not updated until the MENU/SET key is pressed. Make sure to press the
MENU/SET key to update the setting.
Execution condition
1st
2nd
3rd
4th
5th
6th
7th
8th
9th
10th
COMMAND A
COMMAND B
COMMAND C
1
2
3
4
5
30
31
32
Control commands
Execution order
Associating
commands
COMMAND 1
COMMAND 3
COMMAND 4
COMMAND 1 to 32
[Fig. 7.19] Associating control command
[Table 7.18] Control command execution condition
Execution condition
Function
Execution condition
Function
POWER ON
Controlling power
switch
DISPLAY1 POWER ON
Controlling sink device
power of OUT1
DISPLAY2 POWER ON
Controlling sink device
power of OUT2
DISPLAY1 POWER OFF
DISPLAY2 POWER OFF
VIDEO:OUT1-IN1to
VIDEO:OUT1-IN7,
VIDEO:OUT1-OFF
Selecting video input
channel of OUT1
VIDEO:OUT2-IN1to
VIDEO:OUT2-IN7,
VIDEO:OUT2-OFF
Selecting video input
channel of OUT2
AUDIO:OUT1-IN1to
AUDIO:OUT1-IN7,
AUDIO:OUT1-OFF
Selecting audio input
channel of OUT1
AUDIO:OUT2-IN1to
AUDIO:OUT2-IN7,
AUDIO:OUT2-OFF
Selecting audio input
channel of OUT2
7.13.4 Command execution
Menu Top
→
PRESET COMMAND
→
COMMAND EXECUTION
Setting value CMD 1 to CMD 32
You can execute the registered control commands (CMD 1 to CMD 32).
Only registered control command numbers are displayed as settable values. To execute the control command,
press the
“MENU/SET” key.
【
7.13.1Registering/editing control command