ICP-401UHD Command Guide
50
@GOS
Sink device status
Getting
Command
@GOS,out,mode
Response
@GOS,out,mode,status_1 (,status_2)
Parameter
out: Output channel
1, fixed
mode: Status
0 = All statuses of sink device
1 = HDCP of sink device
2 = HDCP authentication between the ICP and sink device
status_1: HDCP of sink device
Reply example
Description
HDCP SUPPORT
Device with HDCP is connected.
HDCP NOT SUPPORT
Device without HDCP is connected.
HDCP NOT CHECK
HDCP of sink device is not checked.
UNCONNECTED
Sink device is not connected.
status_2: HDCP authentication between the ICP and sink device
Reply example
Description
HDCP OFF
Signal with HDCP is not input
HDCP OK
Authentication succeeded
HDCP ERROR
Authentication failed
HDCP CHECK NOW
Being authentication processing
Getting
example
Command
Response
@GOS,1,0
@GOS,1,0,HDCP SUPPORT,HDCP OK
Description
Getting all statuses of sink device
- HDCP of the sink device : HDCP
- HDCP authentication : Succeeded