3. Hardware Factory Reset
※
Wear an anti-static bracelet and insulating gloves before resetting the device.
※
When resetting the camera, keep the power on.
※
For W/WR model, factory reset function is applied from F/W version
‘HiDual_V5.0.1.200603-060309’
3.1 DC-TH2011
1. Loosen the M3x08 screws at the bottom
of DC-TH2011.
2. Remove the thermal pad attached to the
12P cable housing.
5. Assemble the camera in reverse order.
- Be aware of the M/B slide
- Pay attention to the position of the thermal pad and reattach it (12P cable housing)
3. Using a plier, grasp the ground hole of
the M/B and pull down.
4. Press the hard reset button located on the
M/B for 7-8 seconds. The reset takes
about a minute to be completed.