Idis DC-S3283X Скачать руководство пользователя страница 3

Before reading this manual

3

Safety Precautions

WARNING

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING

: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

Important Safeguards

1. Read Instructions

All the safety and operating instructions should be read before the 
appliance is operated.

2. Retain Instructions

The safety and operating instructions should be retained for future 
reference.

3. Cleaning

Unplug this equipment from the wall outlet before cleaning it. Do not 
use liquid aerosol cleaners. Use a damp soft cloth for cleaning.

4. Attachments

Never add any attachments and/or equipment without the approval 
of the manufacturer as such additions may result in the risk of fire, 
electric shock or other personal injury.

5. Water and/or Moisture

Do not use this equipment near water or in contact with water.

6. Placing and Accessories

Do not place this equipment on an wall or ceiling that is not strong 
enough to sustain the camera. The equipment may fall, causing 
serious injury to a child or adult, and serious damage to the 
equipment. Wall or shelf mounting should follow the manufacturer's 
instructions, and should use a mounting kit approved by the 
manufacturer.

This equipment and cart combination should be moved with care.  
Quick stops, excessive force, and uneven surfaces may cause the 
equipment and cart combination to overturn.
Do not place this equipment in an enclosed space. Sufficient 
ventilation is required to prevent an increase in ambient temperature 
which can cause malfunction or the risk of fire.

7. Power Sources

This equipment should be operated only from the type of power 
source indicated on the marking label. If you are not sure of the 
type of power, please consult your equipment dealer or local power 
company.
You may want to install a UPS (Uninterruptible Power Supply) 
system for safe operation in order to prevent damage caused by an 
unexpected power stoppage.  Any questions concerning UPS, consult 
your UPS retailer.

8. Power Cord

Operator or installer must remove power and TNT connections before 
handling the equipment.

9. Lightning

For added protection for this equipment during a lightning storm, 
or when it is left unattended and unused for long periods of time, 
unplug it from the wall outlet and disconnect the antenna or cable 
system. This will prevent damage to the equipment due to lightning 
and power-line surges. If thunder or lightning is common where the 
equipment is installed, use a surge protection device. 

10. Overloading

Do not overload wall outlets and extension cords as this can result in 

the risk of fire or electric shock.

11. Objects and Liquids

Never push objects of any kind through openings of this equipment 
as they may touch dangerous voltage points or short out parts that 
could result in a fire or electric shock.  Never spill liquid of any kind on 
the equipment.

12. Servicing

Do not attempt to service this equipment yourself.  Refer all servicing 
to qualified service personnel.

13. Damage requiring Service

Unplug this equipment from the wall outlet and refer servicing to 
qualified service personnel under the following conditions:
A.  When the power-supply cord or the plug has been damaged.
B.  If liquid is spilled, or objects have hit the equipment.
C.  If the equipment has been exposed to rain or water.
D.  If the equipment does not operate normally by following the 

operating instructions, adjust only those controls that are covered 
by the operating instructions as an improper adjustment of other 
controls may result in damage and will often require extensive work 
by a qualified technician to restore the equipment to its normal 
operation.

E.  If the equipment has been dropped, or the cabinet damaged.
F.  When the equipment exhibits a distinct change in performance — 

this indicates a need for service.

14. Replacement Parts

When replacement parts are required, be sure the service technician 
has used replacement parts specified by the manufacturer or that 
have the same characteristics as the original part. Unauthorized 
substitutions may result in fire, electric shock or other hazards.

15. Safety Check

Upon completion of any service or repairs to this equipment, ask the 
service technician to perform safety checks to determine that the 
equipment is in proper operating condition.

16. Field Installation

This installation should be made by a qualified service person and 
should conform to all local codes.

17. Correct Batteries 

Warning: Risk of explosion if battery is replaced by an incorrect 
type.  Replace only with the same or equivalent type.  Dispose of 
used batteries according to the instructions.  The battery shall not be 
exposed to excessive heat such as sunshine, fire or the like.
Avertissement: risque d'explosion en cas d'utilisation d'une batterie 
de type incorrect. Le remplacer uniquement par un type identique 
ou équivalent.  Mettre les batteries usées au rebut conformément 
aux instructions.  La batterie ne doit pas être exposée à une source de 
chaleur excessive, telle que le soleil, le feu, ou analogue

18. Tmra

A manufacturer’s maximum recommended ambient temperature 
(Tmra) for the equipment must be specified so that the customer and 
installer may determine a suitable maximum operating environment 
for the equipment.

Содержание DC-S3283X

Страница 1: ...Powered by DC S Series Installation Manual DC S3283X DC S3283WHX...

Страница 2: ...problems resulting from the use thereof The information contained herein is subject to change without notice Revisions or new editions to this publication may be issued to incorporate such changes It...

Страница 3: ...ice 10 Overloading Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock 11 Objects and Liquids Never push objects of any kind through openings of t...

Страница 4: ...waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer wher...

Страница 5: ...rview 8 Indoor and Outdoor 8 Flushed 11 Cable 11 Factory Reset 12 Installation 13 Indoor 13 Outdoor 14 Flushed 15 Dimensions 16 Part 2 Camera Connection 17 With DirectIP NVR based Layout 17 With non D...

Страница 6: ...remote monitoring connections IP filtering HTTPS SSL IEEE 802 1X and configurable user authority levels for greater security Network bandwidth limitation and MAT features for more efficient use of net...

Страница 7: ...e the box to make sure all the following accessories are included External appearances and colors of the accessories may vary depending on the model Indoor Outdoor DC S3283WHX DC S3283X Network Camera...

Страница 8: ...remove insert the SD memory card or perform the factory reset make sure that the waterproof sealing is screwed to the dome cover tightly when reconnecting the dome cover Otherwise the IP67 level is n...

Страница 9: ...provided with the camera It is recommended that you use the camera after grounding it Install Screw When installing an indoor camera it secures the body to the indoor bracket M3 Screw Hole When instal...

Страница 10: ...Screw Hole When installing an indoor camera it secures the body to the indoor bracket M5 Screw Hole When installing an outdoor camera it secures the sun shield to the outdoor bracket Pipe Hole When in...

Страница 11: ...rmation on network connection setup refer to the IDIS Discovery operation manual Power Connect the 24VAC power Audio In Out L_I Connect an audio source to this port line in L_O Connect an amplifier to...

Страница 12: ...is not designed to be connected directly with cable or wire intended for outdoor use Factory Reset Only use the factory reset switch to restore the camera to its factory default settings The factory r...

Страница 13: ...t sunlight it may affect adversely Indoor 1 Screw the indoor bracket to the wall or ceiling by using the wall ceiling mounting screws provided with the camera 2 Make a cable hole in the wall or ceilin...

Страница 14: ...with the camera 3 Hook the safety wire of the outdoor bracket on the safety wire ring of the camera body 4 Use the provided M5 screws to secure the outdoor bracket on to the sun shield 5 Connect the...

Страница 15: ...ed The camera is mounted in the housing 1 Remove the ceiling tile from the ceiling Draw circle whose diameter is 7 87 200 mm on the tile Cut the circle out of the ceiling tile 2 Connect external devic...

Страница 16: ...imensions Indoor DC S3283WHX model 212 mm 8 35 200 mm 7 87 Outdoor DC S3283WHX model 245 mm 9 65 147 mm 5 79 230 mm 9 06 Flushed DC S3283X model 180 mm 7 09 200 mm 7 87 226 5 mm 8 92 130 mm 5 12 94 mm...

Страница 17: ...Monitor Out Alarm Out Sensor In Audio In DirectIP NVR makes it easy to use cameras without extra network configurations Each camera can be controlled via the DirectIP NVR setup menu without any PC Fo...

Страница 18: ...te Compact microSD Memory Card Alarm Out Sensor In Audio Out Audio In Control the camera over the network from software installed on a computer Ideal for using the camera over the network from a remot...

Страница 19: ...verly bright light source adjust the camera s position angle accordingly Video color appears incorrect Check the white balance settings If using the Auto option it may take some time for the white bal...

Страница 20: ...1 15 Day Night IR cut filter with auto switch Pan Tilt Zoom Number of Presets Scans Patterns Tours 256 8 8 8 Pan 360 endless 0 02 to 180 sec Preset 420 s Tilt 200 10 to 190 0 02 to 180 s Preset 420 s...

Страница 21: ...C General Vandal Resistance Yes Out door Ready IP67 Heater IK10 Operating Temperature DC S3283WHX 40 C 60 C 40 F 140 F DC S3283X 10 C 60 C 40 F 140 F Boot Up Temperature DC S3283WHX 20 C 60 C 4 F 140...

Страница 22: ...IDIS Co Ltd For more information please visit at www idisglobal com...

Отзывы: