Idis DC-D1223WX' Скачать руководство пользователя страница 3

Before reading this manual

3

Safety Precautions

WARNING

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING

: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

Important Safeguards

1. Read Instructions

All the safety and operating instructions should be read before the 

appliance is operated.

2. Retain Instructions

The safety and operating instructions should be retained for future 

reference.

3. Cleaning

Unplug this equipment from the wall outlet before cleaning it. Do not 

use liquid aerosol cleaners. Use a damp soft cloth for cleaning.

4. Attachments

Never add any attachments and/or equipment without the approval 

of the manufacturer as such additions may result in the risk of fire, 

electric shock or other personal injury.

5. Water and/or Moisture

Do not use this equipment near water or in contact with water.

6. Placing and Accessories

Do not place this equipment on an wall or ceiling that is not strong 

enough to sustain the camera. The equipment may fall, causing 

serious injury to a child or adult, and serious damage to the 

equipment. Wall or shelf mounting should follow the manufacturer's 

instructions, and should use a mounting kit approved by the 

manufacturer.

This equipment and cart combination should be moved with care.  

Quick stops, excessive force, and uneven surfaces may cause the 

equipment and cart combination to overturn.
Do not place this equipment in an enclosed space. Sufficient 

ventilation is required to prevent an increase in ambient temperature 

which can cause malfunction or the risk of fire.

7. Power Sources

This equipment should be operated only from the type of power 

source indicated on the marking label. If you are not sure of the 

type of power, please consult your equipment dealer or local power 

company.
You may want to install a UPS (Uninterruptible Power Supply) 

system for safe operation in order to prevent damage caused by an 

unexpected power stoppage.  Any questions concerning UPS, consult 

your UPS retailer.
This equipment should be remain readily operable.

8. Power Cord

Operator or installer must remove power and TNT connections before 

handling the equipment.

9. Lightning

For added protection for this equipment during a lightning storm, 

or when it is left unattended and unused for long periods of time, 

unplug it from the wall outlet and disconnect the antenna or cable 

system. This will prevent damage to the equipment due to lightning 

and power-line surges. If thunder or lightning is common where the 

equipment is installed, use a surge protection device.

10. Overloading

Do not overload wall outlets and extension cords as this can result in 

the risk of fire or electric shock.

11. Objects and Liquids

Never push objects of any kind through openings of this equipment 

as they may touch dangerous voltage points or short out parts that 

could result in a fire or electric shock.  Never spill liquid of any kind on 

the equipment.

12. Servicing

Do not attempt to service this equipment yourself.  Refer all servicing 

to qualified service personnel.

13. Damage requiring Service

Unplug this equipment from the wall outlet and refer servicing to 

qualified service personnel under the following conditions:
A.  When the power-supply cord or the plug has been damaged.
B.  If liquid is spilled, or objects have hit the equipment.
C.  If the equipment has been exposed to rain or water.
D.  If the equipment does not operate normally by following the 

operating instructions, adjust only those controls that are covered 

by the operating instructions as an improper adjustment of other 

controls may result in damage and will often require extensive work 

by a qualified technician to restore the equipment to its normal 

operation.

E.  If the equipment has been dropped, or the cabinet damaged.
F.  When the equipment exhibits a distinct change in performance — 

this indicates a need for service.

14. Replacement Parts

When replacement parts are required, be sure the service technician 

has used replacement parts specified by the manufacturer or that 

have the same characteristics as the original part. Unauthorized 

substitutions may result in fire, electric shock or other hazards.

15. Safety Check

Upon completion of any service or repairs to this equipment, ask the 

service technician to perform safety checks to determine that the 

equipment is in proper operating condition.

16. Field Installation

This installation should be made by a qualified service person and 

should conform to all local codes.

17. Correct Batteries 

Warning: Risk of explosion if battery is replaced by an incorrect type.
Replace only with the same or equivalent type. 
Dispose of used batteries according to the instructions.
The battery shall not be exposed to excessive heat such as sunshine, 

fire or the like.

18. Tmra

A manufacturer’s maximum recommended ambient temperature 

(Tmra) for the equipment must be specified so that the customer and 

installer may determine a suitable maximum operating environment 

for the equipment.

Содержание DC-D1223WX'

Страница 1: ...Powered by Network Camera Operation Manual DC D1223WX...

Страница 2: ...roblems resulting from the use thereof The information contained herein is subject to change without notice Revisions or new editions to this publication may be issued to incorporate such changes It i...

Страница 3: ...le system This will prevent damage to the equipment due to lightning and power line surges If thunder or lightning is common where the equipment is installed use a surge protection device 10 Overloadi...

Страница 4: ...t be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other ty...

Страница 5: ...p 11 Network 12 IP Address 12 FEN 13 Port QoS 14 Bandwidth Control 15 Security 16 IEEE 802 1X 17 Video 17 Camera 17 Streaming 22 Webcasting 23 MAT 23 Privacy Masking 24 Audio 25 In Out 25 Event Action...

Страница 6: ...Table of Contents 6 Part 2 IDIS Web 36 Web Live Mode 38 Web Search Mode 40 Part 3 Appendix 43 Setup Menu Tree Remote Setup 43 Index 44 2 3...

Страница 7: ...ual IDIS protocol Control the camera over the network from software installed on a computer or a separate NVR Ideal for using the camera over the network from a remote location Switching Protocols 1 L...

Страница 8: ...p screen Alternatively you can select Network Camera from the main screen and then right click to access the Remote Setup screen System settings can also be changed using a remote program From the Rem...

Страница 9: ...s the camera s hardware and software versions Miscellaneous ONVIF Protocol Select to enable ONVIF protocol use However ONVIF Protocol is available only to users belonging to the standard user groups A...

Страница 10: ...o can interfere with establishing a connection with the other camera If IP Address Admin Port and or SSL settings have been changed Remote Setup will terminate after applying the current settings Date...

Страница 11: ...For more information on webcasting refer to the Webcasting on page 23 User Group settings can only be configured by users belonging to the Administrator group There is no default password for the Admi...

Страница 12: ...assword for ADSL connection and then click OK to log in and retrieve the IP address and other network settings automatically DNS Server Enter the DNS server s IP address By using the DNS server you wi...

Страница 13: ...s have been changed click OK at the bottom of the setup window to save the changes and then setup the FEN Inquire with your network administrator for the FEN Server s IP address or domain name If a DN...

Страница 14: ...he network bandwidth allocation priority list Use 0 if you do not want to assign a QoS level The network environment must support DSCP in order for this feature to function properly Contact your netwo...

Страница 15: ...ream Number 1 if Primary 2 if Secondary and 3 if Tertiary e g rtsp admin 10 0 152 35 554 trackID 1 User admin Password None Camera IP Address 10 0 152 35 RTSP Port Number 554 Stream Primary Via Mobile...

Страница 16: ...pplies SSL protocol protection on data transmitted out However programs and systems that do not support SSL will not be able to connect to the camera If this option has been changed Remote Setup will...

Страница 17: ...ction authentication method Selected method must be identical to the authentication method used on the authentication server EAPOL Version Choose EAP authentication s version EAP Identity EAP Password...

Страница 18: ...horizontally or vertically Sharpness Adjust the sharpness level Adjust the contours to make the images look sharper Increasing the value raises the sharpness level but using too high a value can resul...

Страница 19: ...displayed on the screen This function is suitable when the light source of where the camera is installed is special color Color Temperature Set the color temperature manually Flames Shade Select the t...

Страница 20: ...le minimum and maximum shutter speeds for the lighting conditions in the area where the camera is located With certain features selecting Auto automatically loads settings suitable for the camera s in...

Страница 21: ...and time area in the table Selecting On or Off and clicking the Select All Clear All button sets up or releases Nighttime for all dates and time Switching Level Sets up the switching level between the...

Страница 22: ...or the SD memory card recording feature has been enabled For more information refer to the Settings on page 30 Multi View Streaming Designate a specific area of the screen and stream images from that...

Страница 23: ...service the Allow Anonymous Login option under System User Group must be selected MAT Select the MAT option to use the MAT Motion Adaptive Transmission feature during video transmission and recording...

Страница 24: ...then end of the Inactivity Period and the next motion detection Once motion is detected again the frame rate designated under Streaming is restored immediately MAT Motion Adaptive Transmission is a f...

Страница 25: ...umbers Select the empty space next to a number to assign a name to the corresponding privacy mask Click Delete to remove the selected privacy mask Audio Configure audio in out settings In Out Audio Co...

Страница 26: ...out emails SMTP Server Port Enter the SMTP server s IP address or domain name and port number you received from the network administrator If a DNS server has been set up during network configuration y...

Страница 27: ...ure IP Address Enter the IP address and port number of the remote system that will receive the messages Retry Designate how many reattempts to make if message delivery fails Audio Alarm Select Audio A...

Страница 28: ...er the FTP server s port number User ID Password Enter the user ID and password needed for connecting to the FTP server Settings Configure image and upload settings Upload Type Choose an upload type S...

Страница 29: ...fying the Upload Path or Base File Name you cannot use special characters such as and The resolution of FTP upload image can change depending on the resolution setting applied under Video Streaming Se...

Страница 30: ...es and times on the schedule table or drag to enable disable recording mode Select On or Off and then click Select All Clear All to enable disable recording mode on all dates and times Duration Specif...

Страница 31: ...ode under the Schedule tab is set to Always Time Lapse Off Disables Network Recording Failover Always Records video continuously until recording from the remote program becomes functional again regard...

Страница 32: ...ed event will disable B W Mode and restore IR Cut Filter Alarm Out Select if you wish to generate an alarm out Send Email Select if you wish to send an email Select the Image Attachment option to atta...

Страница 33: ...terval With Motion Ignoring Interval configured no event log or notification is generated for motions detected during a period of time following a motion detection event Daytime Specify when daytime s...

Страница 34: ...the defined time range will not be assumed as events Event Action Select a tampering detection event alert action Alarm Out Select if you wish to generate an alarm out Send Email Select if you wish to...

Страница 35: ...to send out an email if no change is detected in the alarm in status Remote Callback Select this option to send a message to a remote system when the SD memory card is inserted removed and then select...

Страница 36: ...Or http web idisglobal com it is required to enter the camera IP address when logging in If the camera uses the FEN feature you can enter the FEN name registered to the FEN server instead of the came...

Страница 37: ...e Internet Options so that the address bar or the status bar is hidden Tools Internet Options Security Custom level Allow websites to open windows without address or status bars Enable Launching a new...

Страница 38: ...to view the video in full screen Press the ESC key on the keyboard to return to the previous screen 5 Click TYPE 1 to print the current video screen using a printer connected to the computer 6 Click...

Страница 39: ...of audio from the remote locale on speakers Enables two way audio communication with the remote locale Disables audio transmission If the remote locale connected to supports audio transmission TYPE 1...

Страница 40: ...3 Displays time information of the video recording from the remote locale 4 Click TYPE 1 to view the video in full screen Press the ESC key on the keyboard to return to the previous screen 5 Click TYP...

Страница 41: ...on the selected dates is shown on the time table at the bottom of the screen Select a point in time to display video from that moment If multiple recordings are available for the selected point in ti...

Страница 42: ...ote system If no name is entered for the camera the name used at the remote locale is shown on the screen Enable Audio If audio was recorded with the video enabling this option plays audio upon playba...

Страница 43: ...Upload Record Alarm In Alarm Out Camera IP Address General System In Out Motion Detection Email Streaming FEN Date Time Network Tampering Remote Callback Webcasting Port QoS User Group Video Audio MA...

Страница 44: ...9 Compression 22 D Date Time 10 DSCP 14 F FEN Name 13 FEN Server 13 Frame Rate 22 I IPFiltering 16 M MAT 23 N Network Bandwidth Limit 15 O ONVIF Protocol 9 Q Quality 22 R Resolution 22 RTSP Port 14 S...

Страница 45: ......

Страница 46: ...IDIS Co Ltd For more information please visit at www idisglobal com...

Отзывы: