 Model M20 Non-Metallic Page 6 

PRINCIPLE OF PUMP OPERATION

This  ball  type  check  valve  pump 

is powered by compressed air and is 

a  1:1  ratio  design. The  inner  side  of 

one diaphragm chamber is alternately 

pressurized  while  simultaneously 

exhausting  the  other  inner  chamber. 

This causes the diaphragms, which are 

connected by a common rod secured by 

plates to the centers of the diaphragms, 

to move in a reciprocating action. (As 

one diaphragm performs the discharge 

stroke  the  other  diaphragm  is  pulled 

to  perform  the  suction  stroke  in  the 

opposite  chamber.) Air  pressure  is 

applied over the entire inner surface of 

the diaphragm while liquid is discharged 

from the opposite side of the diaphragm. 

The diaphragm operates in a balanced 

condition  during  the  discharge  stroke 

which allows the pump to be operated 

at discharge heads over 200 feet (61 

meters) of water.

For maximum diaphragm life, keep 

the pump as close to the liquid being 

pumped as possible. Positive suction 

head  in  excess  of  10  feet  of  liquid 

(3.048  meters)  may  require  a  back 

pressure regulating device to maximize 

diaphragm life.

Al ternate  pressurizing  a nd 

exhausting of the diaphragm chamber 

is performed by an externally mounted, 

pilot  operated,  four  way  spool  type 

air distribution valve. When the spool 

shifts to one end of the valve body, inlet 

pressure is applied to one diaphragm 

chamber  and  the  other  diaphragm 

chamber  exhausts.  When  the  spool 

shifts to the opposite end of the valve 

body,  the  pressure  to  the  chambers 

is reversed. The air distribution valve 

spool is moved by a internal pilot valve 

which alternately pressurizes one end 

of the air distribution valve spool while 

exhausting the other end. The pilot valve 

is shifted at each end of the diaphragm 

stroke  when  a  actuator  plunger  is 

contacted by the diaphragm plate. This 

actuator plunger then pushes the end 

of the pilot valve spool into position to 

activate the air distribution valve.

The chambers are connected with 

manifolds with a suction and discharge 

check  valve  for  each  chamber, 

maintaining  flow  in  one  direction 

through the pump.

INSTALLATION AND START-UP

Locate  the  pump  as  close  to  the 

product being pumped as possible. 

Keep  the  suction  line  length  and 

number of fittings to a minimum. Do not 

reduce the suction line diameter.

For  installations  of  rigid  piping, 

short sections of flexible hose should 

be  installed  between  the  pump 

and  the  piping.  The  flexible  hose 

reduces  vibration  and  strain  to  the 

pumping system. A surge suppressor 

is  recommended  to  further  reduce 

pulsation in flow.

AIR SUPPLY

Air supply pressure cannot exceed 

100  psi  (7  bar).  Connect  the  pump 

air  inlet  to  an  air  supply  of  sufficient 

capacity  and  pressure  required  for 

desired  performance.  When  the  air 

supply line is solid piping, use a short 

length of flexible hose not less than ½" 

(13mm) in diameter between the pump 

and the piping to reduce strain to the 

piping. The weight of the air supply line, 

regulators and filters must be supported 

by  some  means  other  than  the  air 

inlet  cap.  Failure  to  provide  support 

for  the  piping  may  result  in  damage 

to  the  pump. A  pressure  regulating 

valve  should  be  installed  to  insure 

air  supply  pressure  does  not  exceed 

recommended limits.

AIR VALVE LUBRICATION

The  air  distribution  valve  and  the 

pilot valve are designed to operate 

WITHOUT  lubrication.  This  is  the 

preferred mode of operation. There may 

be instances of personal preference 

or  poor  quality  air  supplies  when 

lubrication  of  the  compressed  air 

supply is required. The pump air system 

will  operate  with  properly  lubricated 

compressed  air  supply.  Proper 

lubrication requires the use of an air line 

lubricator (available from MARATHON) 

set to deliver one drop of SAE 10 non-

detergent oil for every 20 SCFM (9.4 

liters/sec.) of air the pump consumes 

at the point of operation.  Consult  the 

pump’s published Performance Curve 

to determine this.

AIR LINE MOISTURE

Water in the compressed air supply 

can create problems such as icing or 

freezing  of  the  exhaust  air,  causing 

the  pump  to  cycle  erratically  or  stop 

operating. Water in the air supply can 

be reduced by using a point-of-use 

air dryer

 

to supplement the user’s air 

drying equipment. This device removes 

water from the compressed air supply 

and  alleviates  the  icing  or  freezing 

problems.

AIR INLET AND PRIMING

To start the pump, open the air valve 

approximately ½" to ¾" turn. After the 

pump  primes,  the  air  valve  can  be 

opened to increase air flow as desired. 

If opening the valve increases cycling 

rate, but does not increase the rate of 

flow, cavitation has occurred. The valve 

should be closed slightly to obtain the 

most efficient air flow to pump flow ratio.

BETWEEN USES

When the pump is used for materials 

that tend to settle out or solidify when 

not  in  motion,  the  pump  should  be 

flushed  after  each  use  to  prevent 

damage.  (Product  remaining  in  the 

pump  between  uses  could  dry  out  or 

settle out. This could cause problems 

with the diaphragms and check valves 

at  restart.)  In  freezing  temperatures 

the pump must be completely drained 

between uses in all cases.

Содержание Warren Rupp MARATHON M20

Страница 1: ...ervicing 19 Solenoid Shifted Air Valve Drawing 20 Solenoid Shifted Air Valve Parts List 20 Solenoid Shifted Air Distribution Valve option 21 Diaphragm Service Drawing Non Overlay 22 Diaphragm Service...

Страница 2: ......

Страница 3: ...tensile strength and impact resistance NEOPRENE All purpose Resistant to vegetable oils Generally not affected by moderate chemicals fats greases and many oils and solvents Generally attacked by stron...

Страница 4: ...l E5 Solenoid Kit with 110VAC Explosion Proof Coil E6 Solenoid Kit with 220VAC Coil E7 Solenoid Kit with 220VAC Explosion Proof Coil E8 Solenoid Kit with 110VAC 50 Hz Explosion Proof Coil E9 Solenoid...

Страница 5: ...minute BAR PSI HEAD NPSHR FEET METERS Displacement Per Stroke Flow Capacity 46 Gallons 1 74 Liters 0 160 Gallons Per Min 0 605 Lilters Per Min MODEL S20 Non Metallic Performance Curve Performance bas...

Страница 6: ...ev0814 Model M20 Non Metallic Page 4 Dimensions M20 Non Metallic Dimensions in Inches in Millimeters Dimensional tolerance 1 8 3mm Note Porting Flanges are also available with PN10 50mm DIN bolting co...

Страница 7: ...l M20 Non Metallic Page 5 Note Porting Flanges are also available with PN10 50mm DIN bolting configuration Dimensions M20 Non Metallic with Spill Containment Dimensions in Inches in Millimeters Dimens...

Страница 8: ...ible hose reduces vibration and strain to the pumping system A surge suppressor is recommended to further reduce pulsation in flow AIR SUPPLY Air supply pressure cannot exceed 100 psi 7 bar Connect th...

Страница 9: ...c Page 7 CAUTION The air exhaust should be piped to an areafor safe disposition of the product being pumped in the event of adiaphragm failure TYPICAL INSTALLATION GUIDE For Non Metallic Pumps Air Inl...

Страница 10: ...enings and connections Be certain the air supply is locked out or made non operational so that it cannot be started while work is being done on the pump Be certain that approved eye protection and pro...

Страница 11: ...coded YELLOW 364 E P D M Rubber Color coded BLUE 365 Neoprene Rubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 370 Butyl Rubber Color coded BROWN 371 Philthane Tuftane 374 Carboxyl...

Страница 12: ...er Corrective Action Remove muffler screen clean or de ice and reinstall Refer to the Air Exhaust section of your pump SERVICE MANUAL What to Check Pumped fluid in air exhaust muffler Corrective Actio...

Страница 13: ...m20nmdl3sm rev0814 Model M20 Non Metallic Page 11...

Страница 14: ...Gaskets Retaining Rings Air Valve Sleeve Spool Set and Pilot Valve Assembly 476 257 354 WETTED END KIT Santoprene Diaphragms Santoprene Balls and TFE Seals 476 257 360 WETTED END KIT Nitrile Diaphrag...

Страница 15: ...000 Air Valve Assembly 1 031 140 001 Air Valve Assembly 031 140 002 Air Valve Assembly w PTFE coated Hardware 1 031 141 000 Air Valve Assembly No Integral Muffler 1 031 141 001 Air Valve Assembly No I...

Страница 16: ...revention 2 196 189 552 Chamber Spill Prevention 2 46 286 120 600 Diaphragm Pumping 2 47 518 200 520 Manifold 2 replaces 518 199 520 518 200 520E Manifold 50mm DIN 2 replaces 518 199 520E 518 200 552...

Страница 17: ...ugh the exposed ports 4 Install safety clip item 1 N into the smaller unthreaded hole in one end cap item 1 D This locks the valve spool to one side keeping the pump from shifting Apply air pressure t...

Страница 18: ...umps with Alternate Mesh Sound Dampening Mufflers or Piped Exhaust 1 031 141 000 Air Valve Assembly 1 Includes all items used on 031 140 000 minus items 1 D 1 F 1 J AIR VALVE ASSEMBLY PARTS LIST Item...

Страница 19: ...hes or other contaminates Remove the sleeve if needed and replace both the sleeve and spool with a new sleeve and spool set item 1 A STEP 3 Reassembly of the air valve Install one end cap item 1 E wit...

Страница 20: ...96 559 Cap Muffler 1 1 E 165 098 147 Cap End 2 1 F 530 028 550 Muffler 1 1 G 560 020 360 O Ring 8 1 H 675 044 115 Ring Retaining 2 1 J 710 015 115 Screw Self Tapping 4 1 K 210 008 330 Clip Safety 1 1...

Страница 21: ...s Remove the sleeve if needed and replace both the sleeve and spool with a new sleeve and spool set item 1 A STEP 3 Reassembly of the air valve Install one bumper item 1 C and one end cap item 1 E wit...

Страница 22: ...or protecting switch with short circuit and thermal instantaneous tripping set to rated current shall be connected in series to each solenoid as short circuit protection For very low rated currents of...

Страница 23: ...cycle the pump s air distribution valve an electric solenoid is utilized As the solenoid is powered one of the pump s air chambers is pressurized while the other chamber is exhausted When electric po...

Страница 24: ...Overlay Torque 480 in lbs Torque 480 in lbs Diaphragm Service Drawing Non Overlay Field conversion kit 475 256 000 available for conversion from PTFE Overlay to One Piece bonded Diaphragm Part Descri...

Страница 25: ...sing the capscrews items 11 12 hex nuts and flat washers and tighten Make sure the bumper item 6 is installed over the diaphragm rod Thread the stud of the other diaphragm assembly clockwise into the...

Страница 26: ...t valve Generously lubricate outside diameter of the sleeve and o rings Then carefully insert sleeve into valve body Take CAUTION when inserting sleeve not to shear any o rings Install retaining ring...

Страница 27: ...source is at a higher level than the pump flooded suction condition pipe the exhaust higher than the product source to prevent siphoning spills See illustration 3 at right CONVERTING THE PUMP FOR PIP...

Страница 28: ...s abrasive wear or embedded materials Replace as needed Inspect the check balls items 3 for wear abrasion or cuts on the spherical surface The check valve seats items 38 should be inspected for cuts a...

Страница 29: ...ncrements and the suction elbows can be rotated in 180 increments see optional positioning in the Dual Porting Drawing DUAL PORTING OF THE SUCTION AND SINGLE PORTING OF THE PUMP DISCHARGE To convert t...

Страница 30: ...0 60Hz Kit 032 045 000 12 32VDC To install electronic leak detectors remove the bottom NPT pipe plug on the visual sight tube item 50 Insert leak detector into the pipe tee item 53 LEAK DETECTION OPTI...

Страница 31: ...Stroke Counter Batch Controller or user control devices such as a PLC The Pulse Output Kits mount directly onto the Muffler Cap on theAir Distribution Valve Assembly or onto the air valve and senses...

Страница 32: ...e OPTION 1 530 027 000 Sound Dampening Muffler screws directly into the Air Valve body This muffler is equipped with a porous plastic element OPTION 2 530 010 000 Mesh Muffler screws directly into the...

Страница 33: ...code for detailed grounding instruction and the type of equipment required Take action to prevent static sparking Fire or explosion can result especially when handling flammable liquids The pump pipi...

Страница 34: ...rer Warren Rupp Inc 800 N Main Street P O Box 1568 Mansfield Ohio 44901 1568 USA certifies that Air Operated Double Diaphragm Pump Series M Non Metallic M Metallic and Surge Suppressors comply with th...

Страница 35: ...N 60079 25 2011 For pumps equipped with Pulse Output ATEX Option Quality B V 0344 AODD Pumps and Surge Suppressors For Type Examination Designations see page 2 back AODD Air Operated Double Diaphragm...

Страница 36: ...09ATEX0073 No Yes Yes KEMA 09ATEX0073 CE Pump types M05 M1F M15 M20 and M30 provided with the integral solenoid option II 2 G EEx m c II T5 II 3 2 G EEx m c II T5 II 2 D c IP65 T100o C KEMA 09ATEX007...

Отзывы: