background image

m20nmdl3sm-rev0814 

 Model M20 Non-Metallic Page 1 

INTAKE/DISCHARGE PIPE SIZE

2" Universal Flange

(Fits ANSI & DIN Flange) 

CAPACITY

0 -160 US  Gallons  per minute

(0 - 605 liters per minute)

AIR VALVE

No-lube, no-stall

design

SOLIDS-HANDLING

Up to .66 in. (17mm)

HEADS UP TO

100 psi or 231 ft. of water

(7 bar or 70 meters)

DISPLACEMENT/STROKE

.46 US gallons (1.73 liter)

Quality System

ISO9001 Certified

Environmental 

Management System 

ISO14001 Certified

M20 

Non-Metallic  

Ball Valve

Design Level 3
Air Operated
Double Diaphragm Pump

ENGINEERING, PERFORMANCE

& CONSTRUCTION DATA

See page 2 
for ATEX ratings.

See pages 2, 33 and 34 

for ATEX ratings.

For specific applications, always consult the Warren Rupp “Chemical Resistance Chart” 

CAUTION! 

Operating temperature limitations are as follows:

Materials

 

 Maximum*

 

Minimum*

 

Operating Temperatures

CAUTION:

  Nonmetallic pumps and plastic components are not UV stabilized.  Ultraviolet radiation can damage these parts and negatively affect material properties.  

Do not expose to UV light for extended periods of time.

Nitrile 

General purpose, oil-resistant. Shows good solvent, oil, water and hydraulic fluid resistance. Should not be used with highly polar solvents 

like acetone and MEK, ozone, chlorinated hydrocarbons and nitro hydrocarbons. 

 

PVDF

  A durable fluoroplastic with excellent chemical resistance. Excellent for UV applications. High tensile strength and impact resistance.

 

 

NEOPRENE

  All purpose. Resistant to vegetable oils. Generally not affected by moderate chemicals, fats, greases and many oils and solvents. Generally

attacked by strong oxidizing acids, ketones, esters, nitro hydrocarbons and chlorinated aromatic hydrocarbons.

PTFE  

Chemically inert, virtually impervious. Very few chemicals are known to react chemically with PTFE: molten alkali metals, turbulent liquid or gaseous 

fluorine and a few fluoro-chemicals such as chlorine trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures.

 

FKM (Fluorocarbon)

  shows good resistance to a wide range of oils and solvents; especially all aliphatic, aromatic and halogenated hydrocarbons, acids, 

animal and vegetable oils. Hot water or hot aqueous solutions (over 70°F) will attack FKM. 

Santoprene

® 

 Injection molded thermoplastic elastomer with no fabric layer. Long mechanical flex life. Excellent abrasion resistance.

 

Polypropylene  

A thermoplastic polymer. Moderate tensile and flex strenght. Resists strong acids and alkalie. Attacked by chlorine, fuming nitric acid and 

other strong oxidizing agents.

 

190°F 

-10°F

88°C 

-23°C

 

250°F 

    0°F

121°C 

-18°C

 

 

200°F 

-10°F

93°C 

-23°C

 

220°F 

-35°F

104°C 

-37°C

350°F 

-40°F

177°C 

-40°C

275°F 

-40°F

135°C 

-40°C

180°F 

32°F

  82°C 

  0°C

Maximum and Minimum Temperatures are the limits for which 

these materials can be operated. Temperatures coupled with 

pressure affect the longevity of diaphragm pump components. 

Maximum life should not be expected at the extreme limits of 

the temperature ranges.

Содержание Warren Rupp MARATHON M20

Страница 1: ...ervicing 19 Solenoid Shifted Air Valve Drawing 20 Solenoid Shifted Air Valve Parts List 20 Solenoid Shifted Air Distribution Valve option 21 Diaphragm Service Drawing Non Overlay 22 Diaphragm Service...

Страница 2: ......

Страница 3: ...tensile strength and impact resistance NEOPRENE All purpose Resistant to vegetable oils Generally not affected by moderate chemicals fats greases and many oils and solvents Generally attacked by stron...

Страница 4: ...l E5 Solenoid Kit with 110VAC Explosion Proof Coil E6 Solenoid Kit with 220VAC Coil E7 Solenoid Kit with 220VAC Explosion Proof Coil E8 Solenoid Kit with 110VAC 50 Hz Explosion Proof Coil E9 Solenoid...

Страница 5: ...minute BAR PSI HEAD NPSHR FEET METERS Displacement Per Stroke Flow Capacity 46 Gallons 1 74 Liters 0 160 Gallons Per Min 0 605 Lilters Per Min MODEL S20 Non Metallic Performance Curve Performance bas...

Страница 6: ...ev0814 Model M20 Non Metallic Page 4 Dimensions M20 Non Metallic Dimensions in Inches in Millimeters Dimensional tolerance 1 8 3mm Note Porting Flanges are also available with PN10 50mm DIN bolting co...

Страница 7: ...l M20 Non Metallic Page 5 Note Porting Flanges are also available with PN10 50mm DIN bolting configuration Dimensions M20 Non Metallic with Spill Containment Dimensions in Inches in Millimeters Dimens...

Страница 8: ...ible hose reduces vibration and strain to the pumping system A surge suppressor is recommended to further reduce pulsation in flow AIR SUPPLY Air supply pressure cannot exceed 100 psi 7 bar Connect th...

Страница 9: ...c Page 7 CAUTION The air exhaust should be piped to an areafor safe disposition of the product being pumped in the event of adiaphragm failure TYPICAL INSTALLATION GUIDE For Non Metallic Pumps Air Inl...

Страница 10: ...enings and connections Be certain the air supply is locked out or made non operational so that it cannot be started while work is being done on the pump Be certain that approved eye protection and pro...

Страница 11: ...coded YELLOW 364 E P D M Rubber Color coded BLUE 365 Neoprene Rubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 370 Butyl Rubber Color coded BROWN 371 Philthane Tuftane 374 Carboxyl...

Страница 12: ...er Corrective Action Remove muffler screen clean or de ice and reinstall Refer to the Air Exhaust section of your pump SERVICE MANUAL What to Check Pumped fluid in air exhaust muffler Corrective Actio...

Страница 13: ...m20nmdl3sm rev0814 Model M20 Non Metallic Page 11...

Страница 14: ...Gaskets Retaining Rings Air Valve Sleeve Spool Set and Pilot Valve Assembly 476 257 354 WETTED END KIT Santoprene Diaphragms Santoprene Balls and TFE Seals 476 257 360 WETTED END KIT Nitrile Diaphrag...

Страница 15: ...000 Air Valve Assembly 1 031 140 001 Air Valve Assembly 031 140 002 Air Valve Assembly w PTFE coated Hardware 1 031 141 000 Air Valve Assembly No Integral Muffler 1 031 141 001 Air Valve Assembly No I...

Страница 16: ...revention 2 196 189 552 Chamber Spill Prevention 2 46 286 120 600 Diaphragm Pumping 2 47 518 200 520 Manifold 2 replaces 518 199 520 518 200 520E Manifold 50mm DIN 2 replaces 518 199 520E 518 200 552...

Страница 17: ...ugh the exposed ports 4 Install safety clip item 1 N into the smaller unthreaded hole in one end cap item 1 D This locks the valve spool to one side keeping the pump from shifting Apply air pressure t...

Страница 18: ...umps with Alternate Mesh Sound Dampening Mufflers or Piped Exhaust 1 031 141 000 Air Valve Assembly 1 Includes all items used on 031 140 000 minus items 1 D 1 F 1 J AIR VALVE ASSEMBLY PARTS LIST Item...

Страница 19: ...hes or other contaminates Remove the sleeve if needed and replace both the sleeve and spool with a new sleeve and spool set item 1 A STEP 3 Reassembly of the air valve Install one end cap item 1 E wit...

Страница 20: ...96 559 Cap Muffler 1 1 E 165 098 147 Cap End 2 1 F 530 028 550 Muffler 1 1 G 560 020 360 O Ring 8 1 H 675 044 115 Ring Retaining 2 1 J 710 015 115 Screw Self Tapping 4 1 K 210 008 330 Clip Safety 1 1...

Страница 21: ...s Remove the sleeve if needed and replace both the sleeve and spool with a new sleeve and spool set item 1 A STEP 3 Reassembly of the air valve Install one bumper item 1 C and one end cap item 1 E wit...

Страница 22: ...or protecting switch with short circuit and thermal instantaneous tripping set to rated current shall be connected in series to each solenoid as short circuit protection For very low rated currents of...

Страница 23: ...cycle the pump s air distribution valve an electric solenoid is utilized As the solenoid is powered one of the pump s air chambers is pressurized while the other chamber is exhausted When electric po...

Страница 24: ...Overlay Torque 480 in lbs Torque 480 in lbs Diaphragm Service Drawing Non Overlay Field conversion kit 475 256 000 available for conversion from PTFE Overlay to One Piece bonded Diaphragm Part Descri...

Страница 25: ...sing the capscrews items 11 12 hex nuts and flat washers and tighten Make sure the bumper item 6 is installed over the diaphragm rod Thread the stud of the other diaphragm assembly clockwise into the...

Страница 26: ...t valve Generously lubricate outside diameter of the sleeve and o rings Then carefully insert sleeve into valve body Take CAUTION when inserting sleeve not to shear any o rings Install retaining ring...

Страница 27: ...source is at a higher level than the pump flooded suction condition pipe the exhaust higher than the product source to prevent siphoning spills See illustration 3 at right CONVERTING THE PUMP FOR PIP...

Страница 28: ...s abrasive wear or embedded materials Replace as needed Inspect the check balls items 3 for wear abrasion or cuts on the spherical surface The check valve seats items 38 should be inspected for cuts a...

Страница 29: ...ncrements and the suction elbows can be rotated in 180 increments see optional positioning in the Dual Porting Drawing DUAL PORTING OF THE SUCTION AND SINGLE PORTING OF THE PUMP DISCHARGE To convert t...

Страница 30: ...0 60Hz Kit 032 045 000 12 32VDC To install electronic leak detectors remove the bottom NPT pipe plug on the visual sight tube item 50 Insert leak detector into the pipe tee item 53 LEAK DETECTION OPTI...

Страница 31: ...Stroke Counter Batch Controller or user control devices such as a PLC The Pulse Output Kits mount directly onto the Muffler Cap on theAir Distribution Valve Assembly or onto the air valve and senses...

Страница 32: ...e OPTION 1 530 027 000 Sound Dampening Muffler screws directly into the Air Valve body This muffler is equipped with a porous plastic element OPTION 2 530 010 000 Mesh Muffler screws directly into the...

Страница 33: ...code for detailed grounding instruction and the type of equipment required Take action to prevent static sparking Fire or explosion can result especially when handling flammable liquids The pump pipi...

Страница 34: ...rer Warren Rupp Inc 800 N Main Street P O Box 1568 Mansfield Ohio 44901 1568 USA certifies that Air Operated Double Diaphragm Pump Series M Non Metallic M Metallic and Surge Suppressors comply with th...

Страница 35: ...N 60079 25 2011 For pumps equipped with Pulse Output ATEX Option Quality B V 0344 AODD Pumps and Surge Suppressors For Type Examination Designations see page 2 back AODD Air Operated Double Diaphragm...

Страница 36: ...09ATEX0073 No Yes Yes KEMA 09ATEX0073 CE Pump types M05 M1F M15 M20 and M30 provided with the integral solenoid option II 2 G EEx m c II T5 II 3 2 G EEx m c II T5 II 2 D c IP65 T100o C KEMA 09ATEX007...

Отзывы: