QUANTUM DI HEATER OPERATION / MAINTENANCE MANUAL
4.2.c Module Status Page
Figure 4-3: Module Status Page (single & dual bank version shown)
The module status page shows the temperatures of each of the heater
modules.
If the heater module temperature is shown in black lettering with a white
background, the module is functioning properly. If a heater module
temperature is displayed with blue lettering, the heater is running too cool
compared to the other heaters in the bank. If a heater module
temperature is displayed with red lettering, the heater is running too hot.
Heaters running too hot or too cold should be checked as soon as
possible. See Section 7.1.a.
The numbered buttons bellow each temperature status box correspond to
the heater modules. These buttons enable or disable each modules
thermocouple. When enabled, the thermocouple is considered in the
temperature control algorithm and is monitored for the Thermocouple
Open Alarm condition (see Section 4.2.b).
The buttons on the bottom of the page will take you to the other pages.
4.2.d Process Plot Page