Installation in Explosive and Fire Danger Zones

Micropump offers products designed and tested for installation in explosive or 

fi

 re danger 

zones. Contact your local Micropump distributor or contact Micropump directly to deter-

mine if your EagleDrive product combination can be certi

fi

 ed for this use.

In addition to the warnings provided throughout this manual, the following must be consid-

ered in any explosion or 

fi

 re danger zone installation:

Ensure the pump head, motor, and any mounting adapter are suitable for 
area classi

fi

 cation.

Limits of Use

The EagleDrive motor is intended for use with pumps handling 

fl

 uids in a variety of pump-

ing systems.  These 

fl

 uids may be innocuous or hazardous, depending on the speci

fi

 c 

application.  You should contact your local Micropump distributor or contact Micropump 
directly about special limitations of your pump/motor unit with regard to your speci

fi

 c 

system.

To achieve optimum performance and safe operation Micropump products must be 
operated with the limits given in the Technical Speci

fi

 cation. Operation outside these 

limits is not recommended and may result in damage to the pump, motor, and/or ancillary 
equipment.

Temperature. Operating beyond the maximum operating temperature 
given in the Technical Speci

fi

 cation is not recommended and may result 

in damage to the product and compromise safety by creating high surface 
temperature.

CAUTION

CAUTION

CAUTION

Corrosive Liquids. Corrosive liquids may eventually produce leak paths 
around the sealing surfaces of the product. The product should be 
inspected for leaks on a regular basis.

Flooding and Water Immersion. The products covered by this guide 
are not designed to operate immersed in water. Refer to the Technical 
Speci

fi

 cation for the environmental rating.

Condensation. When pumping cold liquids ensure that condensation does 
not present a safety hazard. Condensation on the external surfaces of the 
magnet cup may result in a short-circuit in the motor controller.

Mechanical Danger. The product must be installed in a location that 
exposes it to a low risk of external damage.

Hot Surfaces. Under some operating conditions, surface temperatures can 
exceed 90°C (195°F.) Do not touch products while operating. Do not touch 
within 30 minutes of system shutdown to allow surfaces to reach safe 
handling temperature.

Description

The EagleDrive is a brushless DC motor with integrated controller specially designed to 
be electromagnetically coupled to a variety of Micropump pump heads. When properly 
assembled to the pump head with sealing o-ring, this comprises a sealed unit where 
the driven magnet is within a magnet cup that separates the pumped 

fl

 uid from the 

atmosphere. 

The enclosed versions are within a thermoplastic housing.  The motor is capable 
of rotating in both directions and has several other speed control input options.  A 
tachometer signal, with a 0-5 V square-wave output provides speed feedback.  The 
tachometer output has 2 pulses per revolution.  The output frequency is multiplied by 30 
to obtain RPM.  The main input power is 12-36 VDC from a class 2 (SELV) source.

There are two EagleDrive models, the DEMSE and DEELE.  Both models are available in 
12-36 VDC versions, with speed control and power supply as separate functions.  Each 
model has 0-5 V square wave tachometer feedback and FWD/REV capability.
Both EagleDrive models can be controlled using one of these options:
1. Externally applied 0-5 VDC supply
2. Externally applied PWM (Pulse Width Modulation) signal
3. Externally applied 4-20 mA signal (conditioned with resistor)
4. Manually-adjusted speed control (through use of potentiometer)

Function

The driven magnet is connected to the pumping parts and is sealed in the magnet cup. 
This magnet forms the rotor of the brushless DC motor and is driven by the rotating 
magnetic 

fi

 eld in the stator. Rotation of the pumping elements produces 

fl

 ow.

The control signal (supplied internally or externally) controls pump speed. Internal 
feedback monitors the rotational speed of the pump and regulates the speed in relation to 
the control voltage. The controller increases current to regulates speed against increasing 
back pressure (within the operating limits of the pump and motor).

Ensure that pumping liquid temperature, and motor housing temperature 
are maintained within acceptable range as speci

fi

 ed by Micropump 

Certi

fi

 cation of ATEX Conformity.

Содержание MICROPUMP EagleDrive DEMSE

Страница 1: ...STALLATION OPERATION AND WARRANTY INFORMATION EAGLEDRIVE TM EagleDriveTM DEMSE EagleDriveTM DEELE Without Enclosure Without Enclosure DEMSN DEELN CALL TOLL FREE 877 742 2878 FOR SALES AND SUPPORT Retu...

Страница 2: ...nd power cables The Power Supply Assembly means only the printed circuit board and the electronic or mechanical components located inside or on the power supply enclosure and the Pump head Assembly me...

Страница 3: ...is Guide is to provide information to enable suitably qualified technicians and fitters to install operate and maintain the Micropump EagleDrive and common pump motor combinations Use the Guide when y...

Страница 4: ...ow risk of external damage Hot Surfaces Under some operating conditions surface temperatures can exceed 90 C 195 F Do not touch products while operating Do not touch within 30 minutes of system shutdo...

Страница 5: ...ews 4 supplied with the EagleDrive Torque screws to 0 8 N m 7 in lbs Loose bolts may result in pump motor misalignment Tighten bolts appropriately Pump motor misalignment may result in weakening the s...

Страница 6: ...age source and the frequency counter if used will be forced to the same ground reference when connected to the EagleDrive Ensure only one earth ground is used to avoid ground loops Using The Tachomete...

Страница 7: ...e the magnets inside the pump Ensure pump is correctly attached to EagleDrive 1 0 Internal Short Disabled Drive components have failed Reset EagleDrive by disconnecting and restoring power supply conn...

Страница 8: ...the EagleDrive by first setting the external control signal input to the minimum value then switch off the power supply Check that the unit runs down in a steady manner Close the inlet and discharge v...

Страница 9: ...mp periodically The pump cannot be drained completely a certain amount of liquid will remain in the magnet cup area Ensure that the pump is either flushed with a suitable flushing agent or precautions...

Страница 10: ...Out lead is connected to the positive input of the frequency counter Check that the common lead of the frequency counter is connected to the motor Common lead Check leads to ensure no short circuits...

Страница 11: ...Current Nominal Voltage 25 C Ambient 2 9A 24 VDC Speed Control 0 to 5 VDC Tachometer Out 0 to 5 VDC square wave 2 pulse per revolution Thermal Shutdown 135 C Thermal Restart 120 C Storage Temperature...

Страница 12: ...8684 USA Tel 1 360 253 2008 Fax 1 360 253 8294 E mail info micropump idexcorp com Web www micropump com To purchase pumps parts or receive further information contact your local Micropump distributor...

Отзывы: