background image

16

DOC No: 8540 REV E

17

DOC No: 8540 REV E

To maintain protection of internal drive controller, your external 
potentiometer should be 

fi

 tted with appropiate protection.

Manual Control Con

fi

 guration

Manual Control
Install a resistor (sized according to your voltage supply input) across the red Power 
In and black Common lead wires. The potentiometer wiper is connected to the yellow 
Speed Input lead wire. To increase speed, rotate the potentiometer to increase voltage to 
the control line.  To decrease speed, rotate the potentiometer to decrease voltage to the 
control line.

CAUTION

Resistor (38 KOHM)

VISHAY CMF5038K300FHEB

Potentiometer (10 KOHM)

VISHAY P16NP103KAB15

Recommended Parts (24 VDC Mains)

RED

YELLOW

BLACK

Maintenance

Excessive wear to the pump can result in driven magnet rub on the 
magnet cup. This can generate high surface temperatures or degrade the 
capability of the pressure boundary.  Remove the pump from service and 
replace or repair if pump performance degrades signi

fi

 cantly or the pump 

becomes noisy. 

Ensure that heavy deposits of dust are not allowed to accumulate.  Clean 
the pump periodically.

The pump cannot be drained completely, a certain amount of liquid will 
remain in the magnet cup area. Ensure that the pump is either 

fl

 ushed 

with a suitable 

fl

 ushing agent or precautions are taken against the effect 

of any remaining liquid during servicing. When the pump has been 
handling 

fl

 ammable, toxic or hazardous 

fl

 uid, the pump internals must 

be properly decontaminated by suitably quali

fi

 ed personnel. The Material 

Safety Data Sheet for the pumped liquid must be referred to for correct 
procedures and precautions to be followed when handling the liquid.

Micropump EagleDrive motors are designed to be maintenance free and require no 
adjustments. To ensure the motor or pump/motor assembly retains optimum performance 
maintain the 

fl

 uid circuit to keep 

fi

 lters clean and prevent abrasive solids from passing 

through the pump.

A program that includes periodic monitoring of your Micropump product is 
recommended to provide timely detection and assessment of any problem.

NOTE

Magnet Decoupling

The EagleDrive pump/motor combinations do not decouple. If pump load becomes 
excessive, current limiting in the controller prevents motor overload. Additional protection 
is provided by a thermal sensor which shuts down the drive if the internal temperature 
exceeds a preset value.

Содержание MICROPUMP EagleDrive DEELE

Страница 1: ...NSTALLATION OPERATION AND WARRANTY INFORMATION EAGLEDRIVE TM EagleDriveTM DEMSE EagleDriveTM DEELE Without Enclosure Without Enclosure DEMSN DEELN CALL TOLL FREE 877 742 2878 FOR SALES AND SUPPORT Return to BurtProcess com ...

Страница 2: ...and power cables The Power Supply Assembly means only the printed circuit board and the electronic or mechanical components located inside or on the power supply enclosure and the Pump head Assembly means all other parts of the product including but not limited to the rotor No warranty of any kind is made or shall be imposed with respect to any pump or parts 1 that have not been properly installed...

Страница 3: ...his Guide is to provide information to enable suitably qualified technicians and fitters to install operate and maintain the Micropump EagleDrive and common pump motor combinations Use the Guide when you have purchased a motor or pump motor combination This guide contains specific information for installation operation and maintenance of the EagleDrive and references some of the most common pump m...

Страница 4: ...low risk of external damage Hot Surfaces Under some operating conditions surface temperatures can exceed 90 C 195 F Do not touch products while operating Do not touch within 30 minutes of system shutdown to allow surfaces to reach safe handling temperature Description The EagleDrive is a brushless DC motor with integrated controller specially designed to be electromagnetically coupled to a variety...

Страница 5: ...rews 4 supplied with the EagleDrive Torque screws to 0 8 N m 7 in lbs Loose bolts may result in pump motor misalignment Tighten bolts appropriately Pump motor misalignment may result in weakening the sealing of the enclosure Drive housing seal described below is required for IP55 rating Assembly Unpacking and Storage The product should be located with the inlet below or even with the liquid level ...

Страница 6: ...tage source and the frequency counter if used will be forced to the same ground reference when connected to the EagleDrive Ensure only one earth ground is used to avoid ground loops Using The Tachometer Output The tachometer output can be monitored using a frequency counter The tachometer output is 0 5V square wave pulse that occurs twice per pump drive revolution To convert the tachometer output ...

Страница 7: ...te the magnets inside the pump Ensure pump is correctly attached to EagleDrive 1 0 Internal Short Disabled Drive components have failed Reset EagleDrive by disconnecting and restoring power supply connection if problem persists contact Micropump for a replacement 0 1 Low Load Current Operating Drive components have failed Reset EagleDrive by disconnecting and restoring power supply connection if p...

Страница 8: ... the EagleDrive by first setting the external control signal input to the minimum value then switch off the power supply Check that the unit runs down in a steady manner Close the inlet and discharge valves Drain the pump if it is to be shut down for long periods or installed in areas where the liquid may freeze Refer to the Maintenance section for instruction on draining Extended periods of dry r...

Страница 9: ...ump periodically The pump cannot be drained completely a certain amount of liquid will remain in the magnet cup area Ensure that the pump is either flushed with a suitable flushing agent or precautions are taken against the effect of any remaining liquid during servicing When the pump has been handling flammable toxic or hazardous fluid the pump internals must be properly decontaminated by suitabl...

Страница 10: ...r Out lead is connected to the positive input of the frequency counter Check that the common lead of the frequency counter is connected to the motor Common lead Check leads to ensure no short circuits are present Motor is stopped Ensure proper voltage has been applied to motor power leads Ensure proper control input is applied to Control Input lead Ensure control power supply common is connected t...

Страница 11: ... Current Nominal Voltage 25 C Ambient 2 9A 24 VDC Speed Control 0 to 5 VDC Tachometer Out 0 to 5 VDC square wave 2 pulse per revolution Thermal Shutdown 135 C Thermal Restart 120 C Storage Temperature 40 to 135 C Maximum Ambient Operating Temperature 85 C at max load Reversible Yes Weight 0 5 kg Power Output Nominal 52 W Model DEELE EagleDrive Pump Configurations EAGLEDRIVETM DEMSE GA Series GJR S...

Страница 12: ...98684 USA Tel 1 360 253 2008 Fax 1 360 253 8294 E mail info micropump idexcorp com Web www micropump com To purchase pumps parts or receive further information contact your local Micropump distributor or contact Micropump directly MICROPUMP AND THE MICROPUMP LOGO ARE TRADEMARKS OF MICROPUMP INC Your Micropump Distributor Is ...

Отзывы: