Page 4 of 4
0900576 Rev: D (08/03)
TROUBLESHOOTING
Pump or solenoid will not start
•
Push the start button and check pump/solenoid output voltage with volt meter.
•
Make sure Lock-out time is set correctly and not active.
•
Check the external signal voltage.
Pump 1 will activate but pump 2 will not
•
If using lock-out signal check to see what the active lock-out time is for the pump that will activate.
•
Set pump 2’s lock-out time to zero and try to activate the pump.
•
Push start button and check voltage to the pump motor.
•
Check the external signal voltage for pump 2.
Pump is running too long or not for the correct time
•
Re-program the pump for the proper run time.
•
If in Relay Mode make sure that the signal is present for the correct amount of time.
Pump loses or will not hold prime
•
Check or change squeeze tube or roller block.
DISCLAIMER
Knight LLC does not accept responsibility for the mishandling, misuse, or non-performance of the described items
when used for purposes other than those specified in the instructions. For hazardous materials information consult
label, MSDS, or Knight LLC. Knight products are not for use in potentially explosive environments. Any use of our
equipment in such an environment is at the risk of the user, Knight does not accept any liability in such
circumstances.
WARRANTY
All Knight controls and pump systems are warranted against defects in material and workmanship for a period of
ONE year. All electronic control boards have a TWO year warranty. Warranty applies only to the replacement or
repair of such parts when returned to factory with a Knight Return Authorization (KRA) number, freight prepaid, and
found to be defective upon factory authorized inspection. Bearings and pump seals or rubber and synthetic rubber
parts such as “O” rings, diaphragms, squeeze tubing, and gaskets are considered expendable and are not covered
under warranty. Warranty does not cover liability resulting from performance of this equipment nor the labor to
replace this equipment. Product abuse or misuse voids warranty.
Atlanta Branch:
415 Gees Mill Business Court NE,
Suite 200
Conyers, GA 30013 USA
TEL: 770-760-8777
FAX: 770-761-0199
Toronto Branch:
2880 Argentia Road, Unit 6
Mississauga, Ontario
L5N 7X8 Canada
TEL: 905-542-2333
FAX: 905-542-1536
London Branch:
#15 Brunel Centre
Newton Road, Crawley
West Sussex UK RH10 9TU
TEL: 44-1293-615570
FAX: 44-1293-615585
Sydney Branch:
Unit 28, 317-321
Woodpark Rd., Smithfield
NSW Australia 2164
TEL: 61-29-725-2588
FAX: 61-29-725-2025
Amsterdam Branch:
Marssteden 68
7547 TD Enschede
The Netherlands
TEL: 31-53-428-58-00
FAX: 31-53-428-58-09
World Headquarters: 20531 Crescent Bay Drive, Lake Forest, CA 92630-8825 (USA) TEL: 949-595-4800, FAX: 949-595-4801, www.knightequip.com
KNIGHT LLC,
A Unit of IDEX Corporation