TROUBLESHOOTING 

Pump or solenoid will not start 

Push the start button and check pump/solenoid output voltage with volt meter. 

Make sure Lock-out time is set correctly and not active. 

Check the external signal voltage. 

Pump 1 will activate but pump 2 will not 

If using lock-out signal check to see what the active lock-out time is for the pump that will activate. 

Set pump 2’s lock-out time to zero and try to activate the pump. 

Push start button and check voltage to the pump motor. 

Check the external signal voltage for pump 2. 

Pump is running too long or not for the correct time 

Re-program the pump for the proper run time. 

If in Relay Mode make sure that the signal is present for the correct amount of time. 

Pump loses or will not hold prime 

Check or change squeeze tube or roller block. 

 

DISCLAIMER 

Knight LLC does not accept responsibility for the mishandling, misuse, or non-performance of the described items 
when used for purposes other than those specified in the instructions. For hazardous materials information consult 
label, MSDS, or Knight LLC. Knight products are not for use in potentially explosive environments. Any use of our 
equipment in such an environment is at the risk of the user, Knight does not accept any liability in such 
circumstances. 

WARRANTY 

All Knight controls and pump systems are warranted against defects in material and workmanship for a period of 
ONE year. All electronic control boards have a TWO year warranty. Warranty applies only to the replacement or 
repair of such parts when returned to factory with a Knight Return Authorization (KRA) number, freight prepaid, and 
found to be defective upon factory authorized inspection. Bearings and pump seals or rubber and synthetic rubber 
parts such as “O” rings, diaphragms, squeeze tubing, and gaskets are considered expendable and are not covered 
under warranty. Warranty does not cover liability resulting from performance of this equipment nor the labor to 
replace this equipment. Product abuse or misuse voids warranty. 

Atlanta Branch: 

415 Gees Mill Business Court NE, 

Suite 200 

Conyers, GA 30013 USA 

TEL: 770-760-8777 
FAX: 770-761-0199

Toronto Branch: 

2880 Argentia Road, Unit 6 

Mississauga, Ontario 

L5N 7X8 Canada 

TEL: 905-542-2333 
FAX: 905-542-1536

London Branch: 

#15 Brunel Centre 

Newton Road, Crawley 

West Sussex UK RH10 9TU 

TEL: 44-1293-615570 
FAX: 44-1293-615585

Sydney Branch: 

Unit 28, 317-321 

Woodpark Rd., Smithfield 

NSW Australia 2164 

TEL: 61-29-725-2588 

FAX: 61-29-725-2025

Amsterdam Branch: 

Marssteden 68 

7547 TD Enschede 

The Netherlands 

TEL: 31-53-428-58-00 

FAX: 31-53-428-58-09 

World Headquarters: 20531 Crescent Bay Drive, Lake Forest, CA 92630-8825 (USA) TEL: 949-595-4800, FAX: 949-595-4801, www.knightequip.com

 

KNIGHT LLC,

  A Unit of IDEX Corporation

 

Отзывы: