RECOMMENDED ACCESSORIES

Pressure/Vacuum Gauges

AJ496

2.50” Dia. Pressure 1/4” NPT 0-60 in. H

2

O and 0-150 mbar

AE133

2.50” Dia. Pressure 1/4” NPT 0-160 in. H

2

O and 0-400 mbar

AE133A

2.50” Dia. Pressure 1/4” NPT 0-200 in. H

2

O

AJ497

2.50” Dia. Vacuum

1/4” NPT 0-60 in. H

2

O and 0-150 mbar

AE134

2.50” Dia. Vacuum

1/4” NPT 0-160 in. H

2

O and 0-400 mbar

AE134F

3.50” Dia. Vacuum

1/4” NPT 0-15 in. HG

Pressure/Vacuum Relief Valves

AG258

1.50” NPT

Adjustable 30-200 in. H

2

O; 200 cfm max

AJ121D

Silencer for AG258 Relief Valve

AG258F

2.50” NPT

Adjustable 25-200 in. H

2

O; 560 cfm max

AJ121G

Silencer for AG258F Relief Valve

PRESSURE – VACUUM GAUGE

PRESSURE – VACUUM RELIEF VALVE

8

Model Number

R1

R2

R3

R4

SDR4, R4P, SDR5, SDR6, R6, R6PP, SDR6P,

R7S, R9,

R4H, R5

R6P, R7M

R6PS, R7, R7S R9P, R9S

Part Number

AJ151A

AJ151B

AJ151C

AJ151D

AJ151E

AJ151G

AJ151H

AJ151M

Dimension (A)

5.88”

7.38”

7.38”

7.38

8.75

8.75”

14.00”

18.50”

Dimension (A1)

16.25”

20.75”

Dimension (B)

4.50”

6.81”

6.81”

6.81”

10.25”

10.50”

27.13”

28.13”

Dimension (C)

2.75”

4.62”

4.62”

4.62”

5.00”

5.50”

18.50”

19.50”

Dimension (D)

1.00” FPT 1.00” FPT 1.25” FPT

1.50” FPT

2.00” FPT

2.50” FPT

3”MPT

5” MPT

Dimension (E)

1.00” FPT 1.00” FPT 1.25” FPT

1.50” FPT

2.00” FPT

2.50” FPT

3”MPT

5” MPT

Replacement

AJ135D

AJ135E

AJ135E

AJ135E

AJ135F

AJ135G

AJ135C

AJ135H

Element

Micron

10

10

10

10

10

10

10

10

INLINE FILTERS (FOR VACUUM)

The impeller of a blower passes very closely to the housing. It is recommended

to have an inlet or in-line filter to ensure a trouble-free service life.

MPT = Male Pipe Thread

FPT = Female Pipe Thread

Содержание GAST R1

Страница 1: ...50A Shown Model R7P Shown Product Use Criteria Pump only clean dry air Operate at 20 F 104 F 29 C 40 C Protect unit from dirt moisture Do not pump flammable or explosive gases or use in an atmosphere...

Страница 2: ...arge blowers WARNING DANGER c Disconnect electrical power at the circuit breaker or fuse box before installing this product Install this product where it will not come into contact with water or other...

Страница 3: ...product to overheat The following table indicates the correct size cord for length required and the ampere rating listed on the product nameplate If in doubt use the next heavier gage cord The smaller...

Страница 4: ...e thermally protected and will automatically re start when protector resets If product is hard wired into system disconnect electrical power at the circuit breaker or fuse box before performing mainte...

Страница 5: ...ith respect to persons business or property whether as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REMEDY AGAINST GAST FOR GOODS...

Страница 6: ...High Voltage Low Voltage High Voltage T14 T15 T16 T4 T5 T6 T7 T8 T9 T1 T2 T3 To reverse rotation on any 3 Phase motor interchange any two external motor line connections to any two line leads Models R...

Страница 7: ...SDR4 R6 R6P SDR6P R7 R7S SDR4 R4P SDR6 R6PS Part Number AH326B AH326C AH326D AH326F AH326G Dimension A 3 57 4 19 4 50 5 25 8 00 Dimension B 2 32 2 69 2 94 3 82 5 07 Dimension C 1 00 NPT 1 25 NPT 1 50...

Страница 8: ...del Number R1 R2 R3 R4 SDR4 R4P SDR5 SDR6 R6 R6PP SDR6P R7S R9 R4H R5 R6P R7M R6PS R7 R7S R9P R9S Part Number AJ151A AJ151B AJ151C AJ151D AJ151E AJ151G AJ151H AJ151M Dimension A 5 88 7 38 7 38 7 38 8...

Страница 9: ...lowers are drip proof when mounted as shown MPT Male Pipe Thread FPT Female Pipe Thread MUFFLERS Designed to reduce noise by up to 5 dbA and remove high frequency sound associated with all blowers 9 P...

Страница 10: ...AJ102K AJ102K AJ102KA AJ102KA 2 AJ102KA 2 AJ102GZ AJ102GA 4 SQUARE KEY 1 AB136 AB136 AB136 AB136 2 AB136 2 AC628 AC628 5 SHIM SPACER AJ109 AJ169F AJ169F AJ169F AJ169F AJ110 AJ110 6 RETAINING RING 1 7...

Страница 11: ...EXPLODED PRODUCT VIEW 11...

Страница 12: ...ve and pressure or vacuum vacuum gauge Unusual sound Impeller is damaged or dirty Clean or replace impeller Bearing going bad Send unit to a Gast Authorized Service Facility Motor overload Low voltage...

Отзывы: