background image

Select fuses, motor protective switches or thermal

protective switches to provide protection. Fuses act as

short circuit protection for the motor, not as protection

against overload. Incoming line fuses must be able to

withstand the motorʼs starting current. Motor starters

with thermal magnetic overload or circuit breakers

protect motor from overload or reduced voltage

conditions. Motors without automatic restart require

thermal protection or magnetic over-current cutout to

prevent motor overloading from one phase in a 3-phase

circuit, high starting frequency or jammed blower.

The power required will rise as differential pressure

increases. The wiring diagram attached to the product

or on page 6 of this manual provides required electrical

information. Large motors have two diagrams, one for

50Hz wiring specifications and the other for 60Hz wiring

specifications. Check that the power source is correct

to properly operate the dual-voltage motor. If additional

information is required, please consult your Gast

Distributor/Representative.

Model with a power supply cord:

This product must be grounded. For either 120-volt or

220/240-volt circuits connect power supply cord

grounding plug to a matching grounded outlet.

Do not

use an adapter.

(See DIAGRAM A)

Model that is permanently wired:

This product must be connected to a grounded,

metallic, permanent wiring system, or an equipment

grounding terminal or lead on the product.

Power supply wiring must conform to all required safety

codes and be installed by a qualified person. Check

that supply voltage agrees with that listed on product

nameplate.

Extension cords:

Use only a 3-wire extension cord that has a 3-blade

grounding plug. Connect extension cord plug to a

matching 3-slot receptacle.

Do not use an adapter.

Make sure your extension cord is in good condition.

Check that the gage wire of the extension cord is the

correct size wire to carry the current this product will

draw.

An undersized cord is a potential fire hazard, and will

cause a drop in line voltage resulting in loss of power

causing the product to overheat. The following table

indicates the correct size cord for length required and

the ampere rating listed on the product nameplate.

If in

doubt, use the next heavier gage cord. The smaller the

gage number, the heavier the wire gage.

Check with a qualified electrician or serviceman if the

grounding instructions are not completely understood,

or if you are not sure whether the product is properly

grounded. Do not modify the plug provided. If it will not

fit the outlet, have the proper outlet installed by a

qualified electrician.

In the event of an electrical short circuit, grounding

reduces the risk of electric shock by providing an

escape wire for the electric current. This product may

be equipped with a power supply cord having a

grounding wire with an appropriate grounding plug.

The plug must be plugged into an outlet that is properly

installed and grounded in accordance with all local

codes and ordinances.

Electrical Connection

c

This product must be properly grounded.

Do not modify the plug provided. If it will not
fit the outlet, have the proper outlet installed
by a qualified electrician.

If repair or replacement of the cord or plug is
necessary, do not connect the grounding wire
to either flat blade terminal. The wire with
insulation that is green or green with yellow
stripes is the grounding wire.

Check the condition of the power supply wiring.
Do not permanently connect this product to
wiring that is not in good condition or is
inadequate for the requirements of this product.

Failure to follow these instructions can result in
death, fire or electrical shock.

WARNING

Electrical Shock Hazard

Grounded Plug

Grounding Pin

Grounded Outlet

120-volt grounded connectors

shown. 220/240-volt grounded

connectors will differ in shape.

DIAGRAM A

Minimum gage for extension cords

Amps

Volts

Length of cord in feet

120v

25 50

100 150 200 250 300 400 500

240v

50 100 200 300 400 500 600 800 1000

0-2

18 18

18

16

16

14

14

12

12

2-3

18 18

16

14

14

12

12

10

10

3-4

18 18

16

14

12

12

10

10

8

4-5

18 18

14

12

12

10

10

8

8

5-6

18 16

14

12

10

10

8

8

8

6-8

18 16

12

10

10

8

6

6

6

8-10

18 14

12

10

8

8

6

6

4

10-12

16 14

10

8

8

6

6

4

4

12-14

16 12

10

8

6

6

6

4

2

14-16

16 12

10

8

6

6

4

4

2

16-18

14 12

8

8

6

4

4

2

2

18-20

14 12

8

6

6

4

4

2

2

3

Содержание GAST R1

Страница 1: ...50A Shown Model R7P Shown Product Use Criteria Pump only clean dry air Operate at 20 F 104 F 29 C 40 C Protect unit from dirt moisture Do not pump flammable or explosive gases or use in an atmosphere...

Страница 2: ...arge blowers WARNING DANGER c Disconnect electrical power at the circuit breaker or fuse box before installing this product Install this product where it will not come into contact with water or other...

Страница 3: ...product to overheat The following table indicates the correct size cord for length required and the ampere rating listed on the product nameplate If in doubt use the next heavier gage cord The smaller...

Страница 4: ...e thermally protected and will automatically re start when protector resets If product is hard wired into system disconnect electrical power at the circuit breaker or fuse box before performing mainte...

Страница 5: ...ith respect to persons business or property whether as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REMEDY AGAINST GAST FOR GOODS...

Страница 6: ...High Voltage Low Voltage High Voltage T14 T15 T16 T4 T5 T6 T7 T8 T9 T1 T2 T3 To reverse rotation on any 3 Phase motor interchange any two external motor line connections to any two line leads Models R...

Страница 7: ...SDR4 R6 R6P SDR6P R7 R7S SDR4 R4P SDR6 R6PS Part Number AH326B AH326C AH326D AH326F AH326G Dimension A 3 57 4 19 4 50 5 25 8 00 Dimension B 2 32 2 69 2 94 3 82 5 07 Dimension C 1 00 NPT 1 25 NPT 1 50...

Страница 8: ...del Number R1 R2 R3 R4 SDR4 R4P SDR5 SDR6 R6 R6PP SDR6P R7S R9 R4H R5 R6P R7M R6PS R7 R7S R9P R9S Part Number AJ151A AJ151B AJ151C AJ151D AJ151E AJ151G AJ151H AJ151M Dimension A 5 88 7 38 7 38 7 38 8...

Страница 9: ...lowers are drip proof when mounted as shown MPT Male Pipe Thread FPT Female Pipe Thread MUFFLERS Designed to reduce noise by up to 5 dbA and remove high frequency sound associated with all blowers 9 P...

Страница 10: ...AJ102K AJ102K AJ102KA AJ102KA 2 AJ102KA 2 AJ102GZ AJ102GA 4 SQUARE KEY 1 AB136 AB136 AB136 AB136 2 AB136 2 AC628 AC628 5 SHIM SPACER AJ109 AJ169F AJ169F AJ169F AJ169F AJ110 AJ110 6 RETAINING RING 1 7...

Страница 11: ...EXPLODED PRODUCT VIEW 11...

Страница 12: ...ve and pressure or vacuum vacuum gauge Unusual sound Impeller is damaged or dirty Clean or replace impeller Bearing going bad Send unit to a Gast Authorized Service Facility Motor overload Low voltage...