background image

 

 
CTB-12 

6/27/19 

Page 

2

 of 

3

 

15. Change the name of the spare to the color that was not dispensing 

a. 

For example, if the “C” canister is faulty, then rename the spare canister to 
“C” 

16. Click 

Apply

, then click 

OK

 to save the changes 

17. Click on 

Main (Esc)

 

18. Click on

 Close

 to exit service.exe 

19. Reopen 

SERVICE.EXE

 

20. Enter password 

service

 

21. Click on 

Setup (F4) 

22. Click on 

Dispenser 

tab 

23. Click on 

Options (F5)

 

24. Click on 

Sensors 

tab 

25. Click on the newly activated colorant 

a. 

For example, colorant “C” 

26. Type in the default value of 

1431

 as the calibration constant  

27. Click 

Apply

 and then click 

OK

 

28. Click on 

Canister 

tab  

29. Click on the canister which is now the spare 

30. Click on 

Remove (F6)

 

31. Wait for the pulse test to complete 

a.  NOTE: the number in the box to the left will turn black when complete 

32. Click on 

Main (Esc)

 

33. Click on

 Close

 to exit 

SERVICE.EXE

 

34. Reopen ColorPro 

35. Click on 

Maintenance

 and click on 

Fill

 

36. Click on the colorant that was remapped 

37. Adjust the level of the colorant by adding the quarts in the 

Input Amount in Quarts 

(F4)

 box 

38. Click 

Press Enter Key

 to accept level change 

39. Click 

Done

 

40. Click on 

Dispense (F2)

 from the main menu of ColorPro 

Отзывы: