Reference Manual for SCR3310 v2 Contact Desktop Reader
Document Version 1.1
Last revised on 2018-07-19
Page 31 of 40
6.1.2.14:
CONTACT_GET_SET_ETU
This Escape command is be used by the HOST to get/set the current ETU for smart cards. Once
set, the new ETU value will take effect immediately.
Input:
The input buffer contains the Escape followed by an 8 bit GET/SET identifier. For SET ETU, a
DWORD specifying the value to be set is following.
Output:
For both Set and Get ETU, the output will be the following.
DataIn =
80 00
DataOut:
00 00 01 40
(4 bytes)
Byte0
Byte1
Byte2
Byte3
Byte4
Byte5
Value
Description
Wait time
Escape
code(0x80)
0x01
SET ETU
BIT31-
BIT24
BIT23-
BIT16
BIT15-
BIT8
BIT7-
BIT0
0x00
GET ETU
-
-
-
-
Byte0
Byte1
Byte2
Byte3
ETU value
BIT31-BIT24 BIT23-BIT16 BIT15-BIT8 BIT7-BIT0