2.0 Configuration
The i-Q350T tag requires no special configuration. Options are configured at the factory. It
is controlled by commands from the ILR Interrogation device.
3.0 Mounting the Tag.
The tag is designed with two mounting holes so it can be firmly mounted onto virtually any
surface. It can be mounted using various methods dependent on the particular application.
Among the common types of mounting are:
•
Screws
•
Rivets
•
Double sided tape
Note: Mounting hardware is not supplied with the tag.
4.0 Technical Specifications
Performance
Read rate Up to 100 tags/s (Identification Code only)
Up to 35 tags/s @ 128 bit data reading
Max. response time < 10 ms (single tag)
Multiple tag handling Up to 2,000 tags in the read zone
Communication
Read/write range: Up to 350 m (free air)
Operating frequency 868 MHz (EC) or 915 MHz (NA) ISM band
Data rate (download to tag) 115.2 kbits/s
Data rate (upload to reader) 115.2 kbits/s
Maximum transmission power 0.75 mW ERP
Certification EN 300 220 (EC), FCC Part 15 (US), Industry Canada
Electrical
Power source Lithium battery (not replaceable)
Expected battery life > 2.5 Years @ 600 times 64 bit readings/day
Battery monitoring: Yes
Data
Data retention >10 years without power
Write cycles 100,000 writes to a tag
Memory size 32Kbytes
Identification code 48 bit fixed ID (one in one trillion)
Environmental
Operating temperature
–
20°C to +70°C (
–
4ºF to +158ºF)
Shock 50 G; 3 times DIN IEC 68-2-27
1-meter multiple drops to concrete
Vibration 3 G; 20 sine wave cycles; 5 Hz to 150 Hz,
DIN IEC 6
5 G; noise 5 Hz to 1000 Hz; 30 minutes
DIN IEC 68-2-64
Package rating
Personnel tag IP69
—
Totally sealed against moisture and dust
Physical
Dimensions: personnel tag 55 mm x 28 mm x 6 mm
Case material: Macromelt OM 652
Mass: 27 grams